Download VMA-200E ATM Adapter User`s Manual
Transcript
Troubleshooting How to check Enter the elconfig show -configured command and note the last error message in the output. Possible Solutions Last error messages and corrective actions are mentioned with each case below. • LES address is zero ( only in autoconfig mode ) or VCI not assigned for LES (only in manual configuration). 1. "LECS failed to find ELAN" Ensure that the ELAN name is correct and is registered with the LECS (in case of auto-configuration only). 2. "LECS failed to respond" If in auto-configuration mode, make sure that the LECS is started and is running. 3. "failed to connect to LES" or "Could not connect to the BUS" Make sure that the services (LES,BUS) are up, and that the services machine is connected to the switch. Make sure that the ATM address of the services machine is correct in the LECS database. 4. If services are UP, check the syslog file (if enabled) for any ERROR conditions and make corrections as appropriate. If services are UP but syslog is not enabled, call FORE Technical Support. 5. Enter the command atmstat fa0 1 and observe the response. a. If atmstat does not respond, call FORE Technical Support. ForeRunner™ VMA-200E ATM VME Bus Adapter User’s Manual 10 - 17 Troubleshooting What is the "Last Error" appearing in the output of the elconfig show -configured command?