Download User manual

Transcript
3. OUTPUTS CARRYING CAPACITY.
6. GENERAL DESCRIPTION.
6.1. ADJUSTMENT .
Temp.
COOLING
Temp.
6°C
F12=1°C
SET1=90°C
F12=1°C
F12=1°C
Time
OUTPUT1
OUTPUT1
30A 250VAC
105 cycles
20A, 4500W
8A, 1500W, 2HP(2KM)
OUTPUT2
8A 250VAC
105 cycles
8A, 1500W
2A, 400W, 0.5HP(0.5KM)
temperautre sensor number
89°C
Time
Maximum inductive
load (for example. engine):
temperature display
HEATING
F12=1°C
4°C
Maximum resistive
load (for example. Heater):
4. FRONT PANEL.
91°C
SET1=5°C
Relay:
Output:
DC20 maintains SET1 and/or SET2 subject temperature with accuracy(hysteresis), which can be
set in F12 and F22 parameter.
Depending on an application 1 and 2 Controller can work in HEATING or COOLING mode.
After choosing measurement form (F10 and F20 parameters) the controller is able
to operate in many variants, for example as a single heating controller with two settings
or as two separate heating controller or as a differential controller with an additional
alarm threshold at the same time.
The most important parameters and temporal courses.
entry to the parameters menu
-
temperature setting button
set
value increasing button
M
value decreasing button
OUTPUT1
temperature setting signalling SET1
temperature setting signalling SET2
1
1
0
0
Time
Time
OUTPUT1 signalling. LIGHTS: output active; BLINKS: output waits for start-up (see: F17)
OUTPUT2 signalling. LIGHTS: output active; BLINKS: output waits for start-up (see: F27)
emergency states signalling. BLINKS: alarm active
6.2. DIGITAL INPUT.
Controller has D1 digital input, which can be used as an alarm input. Then it can signal
emergency states sound signalling, such as system failure, pressure control, safety t h e r m o s t a t
STB or safety button activation. Connect additional security system contacts to D1 contacts (4-5
terminals). Contacts type: NO (normally opened) or NC (normally closed) is set in F50 parameter.
5. CONTROLLER HANDLING.
5.1. TEMPERATURE SETTING.
M
Thermostat
STB
set
T2
1
2
3
4
5
M
set
Heater
14
15 16
lights up.
Confirm the SET 1 by
set Button.
Diode
lights up.
Fan
M
Power supply
230V~
When protection activates, controller switch on/switch off 1 and 2 OUTPUT (F53 and F54
parameters), turns on the sound signal (parameter F53=1) and the display shows AL.d1.
code. Failure signalling an be maintained, till the alarm reset using the buttons (set the
parameter F50=2 or 4).
5
Diode
Using:
M
set
DC-20D
20(8)A 250VAC
11 12 13
Press set button for
2 sec.
set
or
button set the desired
temperature value
SET1.
Using:
M
set
or
button set the desired
temperature value
SET2.
Confirm the SET2 by
set Button.
Diode
goes off.
Remarks:
–Press M button in any time to cancel the setting
–the setting 1 change can be limited by F13 and F14 parameters
–the setting 2 change can be limited by F23 and F24 parameters
3