Download User manual
Transcript
3. OUTPUTS CARRYING CAPACITY. 6. GENERAL DESCRIPTION. 6.1. ADJUSTMENT . Temp. COOLING Temp. 6°C F12=1°C SET1=90°C F12=1°C F12=1°C Time OUTPUT1 OUTPUT1 30A 250VAC 105 cycles 20A, 4500W 8A, 1500W, 2HP(2KM) OUTPUT2 8A 250VAC 105 cycles 8A, 1500W 2A, 400W, 0.5HP(0.5KM) temperautre sensor number 89°C Time Maximum inductive load (for example. engine): temperature display HEATING F12=1°C 4°C Maximum resistive load (for example. Heater): 4. FRONT PANEL. 91°C SET1=5°C Relay: Output: DC20 maintains SET1 and/or SET2 subject temperature with accuracy(hysteresis), which can be set in F12 and F22 parameter. Depending on an application 1 and 2 Controller can work in HEATING or COOLING mode. After choosing measurement form (F10 and F20 parameters) the controller is able to operate in many variants, for example as a single heating controller with two settings or as two separate heating controller or as a differential controller with an additional alarm threshold at the same time. The most important parameters and temporal courses. entry to the parameters menu - temperature setting button set value increasing button M value decreasing button OUTPUT1 temperature setting signalling SET1 temperature setting signalling SET2 1 1 0 0 Time Time OUTPUT1 signalling. LIGHTS: output active; BLINKS: output waits for start-up (see: F17) OUTPUT2 signalling. LIGHTS: output active; BLINKS: output waits for start-up (see: F27) emergency states signalling. BLINKS: alarm active 6.2. DIGITAL INPUT. Controller has D1 digital input, which can be used as an alarm input. Then it can signal emergency states sound signalling, such as system failure, pressure control, safety t h e r m o s t a t STB or safety button activation. Connect additional security system contacts to D1 contacts (4-5 terminals). Contacts type: NO (normally opened) or NC (normally closed) is set in F50 parameter. 5. CONTROLLER HANDLING. 5.1. TEMPERATURE SETTING. M Thermostat STB set T2 1 2 3 4 5 M set Heater 14 15 16 lights up. Confirm the SET 1 by set Button. Diode lights up. Fan M Power supply 230V~ When protection activates, controller switch on/switch off 1 and 2 OUTPUT (F53 and F54 parameters), turns on the sound signal (parameter F53=1) and the display shows AL.d1. code. Failure signalling an be maintained, till the alarm reset using the buttons (set the parameter F50=2 or 4). 5 Diode Using: M set DC-20D 20(8)A 250VAC 11 12 13 Press set button for 2 sec. set or button set the desired temperature value SET1. Using: M set or button set the desired temperature value SET2. Confirm the SET2 by set Button. Diode goes off. Remarks: –Press M button in any time to cancel the setting –the setting 1 change can be limited by F13 and F14 parameters –the setting 2 change can be limited by F23 and F24 parameters 3