CALL NOW 800-985-6929 http://www.automatedpt.com Chapter 4 Parameters| Parameter 08.15 Explanation Factory Customer Setting Settings Auto Restart After Fault 0 to 10 (0=disable) 08.16 Auto Reset Time at Restart after Fault 0.1 to 6000 sec 08.17 Auto Energy Saving 0 60.0 0: Disable 0 1: Enable 0: AVR function enable 08.18 AVR Function 1: AVR function disable 0 2: AVR function disable for decel. 3: AVR function disable for stop 08.19 Software Brake Level 115V / 230V series: 370.0to 430.0V 380.0 460V series: 740.0 to 860.0V 760.0 0.0~5.0 Compensation Coefficient for Motor Instability 0.0 08.21 OOB Sampling Time 0.1 to 120.0 sec 1.0 08.22 Number of OOB Sampling Times 00 to 32 20 08.23 OOB Average Sampling Angle Read only 08.24 DEB Function 08.25 DEB Return Time 0 to 250 sec 08.26 Speed Search during Start-up 0: Disable Speed Search Frequency during Start-up 0: By setting frequency 08.27 08.20 #.# 0: Disable 0 1: Enable 0 0 1: Enable 1: By max. operation frequency (Pr.01.00) 0 Group 9 Communication Parameters Revision Oct. 2009, 07EE, SW--PW V1.14/CTL V2.14 CALL NOW 800-985-6929 4-23 http://www.automatedpt.com