Download User Manual
Transcript
KY-3120DM Industrial Ethernet Switch User Guide for an authentication. The switch sends a unicast request/identity packet to a supplicant system and then triggers the transmission timer. The switch will send another request/identity packet to the supplicant system if it has not received the reply packet from the supplicant system when this timer times out. The second case is when the switch authenticates the 802.1x client who cannot request for authentication actively. The switch sends multicast request/identity packets periodically through the port with 802.1x function enabled. In this case, this timer sets the interval of sending the multicast request/identity packets. The tx-period-value argument ranges from 1 to 65535 (in seconds). By default, the transmission timer is set to 30 seconds. Description Use timeout command to set a specified 802.1x timer. Use no timeout command to restore a specified 802.1x timer to the default setting. Examples (dot1x)# timeout quiet-period 120 Timeout of quiet period has been set 120 seconds (dot1x)# no timeout quiet-period Timeout setting for quiet period has been restored to the default 60 seconds. System-auth-control Syntax system-auth-control no system-auth-control View dot1x view Parameters None. Description Use system-auth-control command to enable 802.1x globally. Use no system-auth-control command to disable 802.1x globally. Examples (dot1x)# system-auth-control 802.1x has been enabled Configuration completed successfully. (dot1x)# no system-auth-control 802.1x is disabled. Configuration completed successfully Radius-server Syntax radius-server host host-ip-address auth-port auth-port-number [ acct-port acct-port-number ] key key-string View dot1x view 127