Download Instruction Manual
Transcript
1. GENERAL The Hydra SX40 Dual Frequency Doppler (DFD) Dedicated Flowmeter is suited for measuring the flow of fluids with undissolved, entrained solids or dispersed gases such as: • • • wastewater–primary sludge and activated sludge, food–dairy and fluidized foods, industrial–crude oil and dredging. 1.1 Flowmeter Specifications 1.1.1 Performance Specifications Velocity Range: 0.2 ft/sec to 32 ft/sec (0.06 m/sec to 10 m/sec) Accuracy: ±1% of velocity full scale Fluids: liquids containing particulate or entrained gas bubbles Pipe Size: 0.5 in to 200 in (12 mm to 5000 mm) 1.1.2 Physical Specifications Transmitter: NEMA 4X (IP 65), flame retardant, fiberglass-reinforced polyester Transducers: two encapsulated DFD sensor heads suitable for submersible/underground service; enclosed in stainless steel shrouds with integral transducer clamps 30 ft (9 m) standard cable length Weight: approximately 12 lbs (5.4 kg) 1