Thunderstorm/Lightning Sensor
and Graphic Display
User's Manual
All Weather Inc. • 1165 National Drive • Sacramento, CA 95834 • USA • www.allweatherinc.com
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
CONTENTS
Introduction ................................................................................................................................ 1
Sensor Theory of Operation....................................................................................................... 2
Detection ............................................................................................................................. 2
Processing........................................................................................................................... 2
Reporting............................................................................................................................. 2
Sensor Installation & Checkout .................................................................................................. 3
RFI/EMI Precautions ........................................................................................................... 3
Sensor Installation ............................................................................................................... 3
Checkout ............................................................................................................................. 7
Graphic Display.......................................................................................................................... 8
Zooming In and Out............................................................................................................. 9
Map Key .............................................................................................................................. 9
Menus ...................................................................................................................................... 10
File Menu........................................................................................................................... 10
Edit Menu .......................................................................................................................... 11
Group and User Authorizations ......................................................................................... 11
Configuration ..................................................................................................................... 16
Port Configuration.............................................................................................................. 21
Points of Interest................................................................................................................ 22
Logs Menu......................................................................................................................... 23
Data Format ............................................................................................................................. 24
Error Messages and Troubleshooting ...................................................................................... 26
Processor LEDs................................................................................................................. 29
Maintenance............................................................................................................................. 30
Periodic Maintenance ........................................................................................................ 30
Specifications........................................................................................................................... 30
Warranty .................................................................................................................................. 31
Page iii
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Introduction
The Model 6502 Thunderstorm/Lightning Sensor detects
electrical discharges associated with thunderstorms within a 200
nautical mile (nm) radius of the system. The Model 6502 is a
passive sensor that listens for electromagnetic signals with a
receiving antenna. There is no transmitter, and so no harmful
transmissions.
The entire package (consisting of an antenna mounted to a 28"
x 32" ground plane, and a processor and interface board housed in
a NEMA 4X enclosure) mounts simply to a 2½" pipe (2.875"
O.D.) using two U-bolts.
The Graphic Display shows detected strikes overlaid onto a
map of the monitored area. A set of pull-down menus allows the
user to configure the display and to add labeled locations to the
map.
Page 1
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Sensor Theory of Operation
Detection
The Model 6502's antenna is a combined crossed-loop and sense antenna, which can
correlate the electric and magnetic signatures of lightning strikes better than other systems
due to its patented sense channel technology. The antenna has been designed to help filter out
pulsed noise from sources other than atmospheric electrical discharges.
The antenna detects the electrical and magnetic fields generated by intra-cloud, intercloud, or cloud-to-ground electrical discharges that occur within a 200 nm radius of the
antenna, and sends the resulting ‘discharge signals’ to the processor. The processor digitizes,
analyzes, and converts the discharge signals into range and bearing data, then stores the data
in memory.
Processing
The Model 6502's processor is housed inside the sensor enclosure along with the Interface
Board. The processor includes data acquisition circuitry and circuitry to process strike data.
The Interface Board provides a data buffer and handles communication.
The sensor transmits a data package consisting of strike data and status information every
five seconds. When errors are detected, the errors are recorded in an error log.
Reporting
The Model 6502 detects the presence of a thunderstorm or lightning event within 200 nm
from the point of installation.
1. Range and Direction
Reports thunderstorms/lightning within a 200 nm radius from the installation point.
2. Resolution
Location of thunderstorm is ±1nm from actual location of the thunderstorm/ lightning.
4. False Reports
Not more than 2%.
Page 2
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Sensor Installation & Checkout
The Thunderstorm/Lightning Sensor package (consisting of an antenna mounted to a 28" x
32" ground plane and a processor housed in a NEMA 4X enclosure) mounts to a 2½" pipe
(2.875" O.D.) using two U-bolts. A section of 2.5" (64 mm) I.D. standard galvanized steel
pipe can be used as a mast with no drawbacks or special adaptation. Refer to the site
preparation instructions and applicable drawings for foundation, grounding, conduit, and
junction box installation details.
CAUTION
The Thunderstorm/Lightning Sensor's ground plane extends well
beyond the edges of the sensor enclosure. Be aware of this
hazard when working around the sensor.
RFI/EMI Precautions
The Model 6502's antenna is sensitive to static charges, so care must be taken to ensure that
the antenna and ground plane are as far removed as possible from composite materials (e.g.,
plastic materials or fiberglass), since these materials have a tendency to build up static
charge.
The sensor should be mounted as far as possible from devices that emit high levels of
radio frequency interference (RFI) and electromagnetic interference (EMI), such as VHF and
UHF radios, RF modems, fluorescent lamps, and ballasts, air conditioner and heater blowers,
as well as any current-carrying cables. General clearance guidelines are:
•
•
•
•
•
•
Strobe lamps and power supplies - 5 ft (1.5 m)
Fluorescent lamps and ballasts - 5 ft. (1.5 m)
Air conditioners and heater blowers - 5 ft. (1.5 m)
Telephone antennas - 4 ft. (1.2 m)
VHF communication antennas - 1 ft. (0.3 m)
Any current-carrying cable - 2 ft. (0.6 m)
In addition to the above restrictions, certain site installations may have to be scrutinized
more carefully from an RFI/EMI perspective. Finding locations to mount the ground plane
and antenna that will minimize interference from RFI/EMI sources can be enhanced by the
use of standard RFI measuring equipment. The recommended equipment for monitoring the
proposed installation area is a typical spectrum analyzer with a broadband conical antenna.
The spectrum analyzer should be set up to scan the frequencies of concern (100-500 MHz)
for the typical VHF and UHF radio links near the installation. Once it has been determined
that there is significant interference, it is imperative that the lightning sensor be moved to a
location as far from the interfering device as possible. Under no circumstances should the
lightning sensor antenna and ground plane be placed within one foot of either a VHF or
UHF transmitting antenna.
Sensor Installation
After installing the mast, conduit, and junction box, follow the instructions below for
assembling and installing the sensor.
Page 3
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
1
If the signal and power cables have not already been installed between the signal and
power distribution boxes and the sensor pad, pull the required lengths of cable
through conduit to the junction boxes at the sensor pad.
2 (See Figure 1). The mounting bracket attaches to the underside of the 6502 enclosure
with 4 bolts. Position the bracket against the underside of the enclosure so that the
mounting holes in the bracket and enclosure align.
3 Apply RTV 162 to the threads of the four 5/16" hex mounting bolts.
4 Fasten the bracket to the enclosure with the four 5/16" hex bolts, flat washers, and
lock washers.
5 Tighten the bolts.
5/16" bolts (x4)
Ground
Clamp
Figure 1. Bracket installation
6
Set the sensor package (antenna, ground plane, enclosure, and bracket) on the mast,
and fasten loosely with two U-bolts, lock washers, and flat washers as shown in
Figure 2.
Enclosure
Signal Cable
Bracket
Power Cable
U-bolts
Figure 2. Sensor package mounting
7 Align the antenna to True North.
8 Tighten the two U-bolts.
Page 4
User's Manual
9
Thunderstorm/Lightning Sensor and Graphic Display
Open the sensor enclosure by loosening the four countersunk bolts shown in Figure
3. Do not remove the six bolts holding the ground plane to the enclosure lid.
Ground plane
Loosen
Loosen
Figure 3. Opening the sensor enclosure
10 The sensor enclosure lid is equipped with hinged bolts (see Figure 4) to allow the
box to be opened with the ground plane attached. Grasp both sides of the ground
plane and lift straight up as far as possible (about 3"), then tilt the ground plane and
lid over carefully to gain access to the enclosure interior. When fully open, the
ground plane will rest against the side of the enclosure.
Figure 4. Enclosure hinges
11 Connect the incoming AC power wires to the AC interface board inside the enclosure
(Figure 5) according to Table 1.
12 Close the enclosure lid and tighten the four countersunk bolts.
13 Fasten a ground wire between the ground cable installed during site preparation and
the ground clamp on the underside of the enclosure (see Figure 1).
Page 5
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Figure 5. Interface board
Table 1. Lightning detector power wiring.
AC Interface Board TB1
Pin
Function
Color
1
HOT
BLACK or BROWN
2
NEUTRAL
WHITE or BLUE
3
GROUND
GREEN
AC Interface
Board
TB1
1
HOT (BLACK or BROWN)
220V
2
NEUT (WHITE or BLUE)
Neutral
3
GND (GREEN)
Ground
AC
Or
AC Interface
Board
TB1
1
Page 6
HOT (BLACK or BROWN)
110V
2
NEUT (WHITE or BLUE)
110V
3
GND (GREEN)
Ground
AC
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Checkout
To verify the sensor is working properly, power the sensor up and verify that, after one
minute of operation, data is reported from the sensor. (Bear in mind that, in the absence of
lightning in the measuring area, the data screens will report no strikes.)
Page 7
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Graphic Display
Lightning data is viewed on a graphic display that shows detected strikes overlaid onto a map
of the monitored area (Figure 6). A set of pull-down menus allows the user to configure the
display and to specify areas of interest for display on the map.
Figure 6. Lightning Graphic Display
The graphic display provides a strike locator overlaid on a map of the area being
monitored. The strike locator indicates both distance and direction of strikes using a grid of
four concentric rings (representing distance ranges from the center point) combined with
directional octants. The center point of the locator is normally the site of the lightning sensor,
and is entered by the user through the Lightning tab on the Edit>Configuration menu.
Each distance ring represents an increased distance from the locator’s center point of 50
nautical miles:
• The innermost ring of the locator shows strikes detected within 50 nautical miles
of the center point.
• The next ring out shows strikes within 100 nautical miles of the center point.
• The third ring out shows strikes within 150 nautical miles of the center point.
• The outermost ring shows strikes within 200 nautical miles of the center point.
Page 8
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
The directional octants divide the strike locator into eight distinct compass directions,
making it simple to quickly identify the direction and distance of detected lightning strikes.
Zooming In and Out
The zoom icons in the upper right of the display allow you to zoom the map view in and out.
•
Click the
icon to zoom in to view a smaller area of the map.
•
Click the
icon to zoom out for a wider picture.
Map Key
Once a strike has been detected, it remains visible on the screen for the
length of time specified in the Decay Time option on the
Configuration menu (see page 18). In order to provide a graphic view of
strikes over time, the color of the strike changes as it ages. As the Map
Key in the lower right corner of the display shows, new strikes are shown
in red. As they age, they become progressively lighter in color, changing
to orange, then yellow, until they finally disappear from the map. In the
example, the decay time has been set to 15 minutes.
The Scale indicator at the bottom of the key shows the distance scale
for the currently displayed map.
Page 9
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Menus
File Menu
The File menu contains options for logging in and out, printing, and
window control.
Login
The Login option is used to log in to the system as a User. Each User has access to
specific screens and functions, as set by the administrator through the User Authorizations
and Group Authorizations options on the Edit menu. The use of these options is explained in
detail in the next section.
•
•
•
To log in, select a User from the pull-down menu.
Enter your password in the Password field, then click OK.
The User name under which you are logged in will be shown in parentheses at the top
of the screen, and all applicable menu options will now be available.
Use the area below to record your system’s username and password:
Username __________________________________________
Password __________________________________________
Logout
To log out of the current group, click Logout. All menu options requiring login will be
grayed out.
Print
The Print option lets you print the current lightning display. When you click Print, the
standard Windows print screen will be displayed.
Print Preview
The Print Preview option lets you see a preview before printing of what the Print command
will output to the printer.
Page Setup
The Page Setup option lets you set printing preferences. Clicking Page Setup will call up
the standard Windows printing options screen.
Page 10
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Minimize
Click the Minimize option to minimize the display. The software will continue running
when minimized. To restore the display to full screen, click the AWI MetObserver icon on
the application toolbar at the bottom of the screen.
Exit
Click the Exit option to close the software. After exiting, the software will continue to
run as normal.
Edit Menu
The Edit menu contains options for setting up group and user
authorizations, configuring the display, configuring ports, and
setting “points of interest”.
Group and User Authorizations
The display software is highly configurable through a series of user menus. Often,
though, configuration changes may best be restricted to authorized users. The Group and
User structure of the software allows permission to be allocated as required to control access
and maintain the integrity of system operations. Authorization menus are generally only
available to Administrators, though those permissions can be given to other groups as well.
•
Group Authorizations allow administrative functions to be enabled or disabled, and
access to the three data views to be assigned.
•
User Authorizations grant group membership to individual users. A user can belong
to one or more groups. On logging in, the user will be granted access to all the
functions allowed for each group in which he has membership.
•
Authorization changes take effect immediately on exiting a configuration dialog and
returning to the main display.
Page 11
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Group Authorizations
The Group Authorizations... option allows administrators to set group permissions.
•
To configure group permissions, log on as an authorized user with Admin rights and
select Edit>Group Authorizations to call up the screen shown in Figure 7.
Figure 7. Group Authorizations Screen
The Group Authorizations screen lists all current groups and the authorized features
available to each. The Authorization Name shows the name of the group, followed by a
series of checkboxes that shows the functions a group is authorized to access. A function is
accessible when it is checked. The table below explains each of the functions.
Function
Admin
Config
Logs
Lightning View
When Checked
Gives the group administrative privileges, including Group and User
Authorization
Lets the group change configuration settings (Edit>Configuration)
Lets the group view and retrieve data logs (Logs menu)
Lets the group select the Lightning view from the View menu
Adding a Group
To add a new group, click the New button at the bottom of the screen. The screen shown
in Figure 8 will be displayed.
Figure 8. New Group Screen
Page 12
User's Manual
•
•
•
•
•
Thunderstorm/Lightning Sensor and Graphic Display
Enter a name for the group.
Select all the features from the Features panel that you want the group to have access
to.
Select all the views from the Views panel that you want the group to have access to.
Click Save to add the group.
Click Cancel to return to the Group Authorizations screen without adding the group.
Editing a Group
To edit a group’s authorizations, highlight a group on the list and click the Edit button at
the bottom of the screen. The screen shown in Figure 9 will be displayed.
Figure 9. Edit Group Screen
•
•
•
Check or uncheck Features and Views to enable (check) or disable (uncheck) access.
Click Save to save the changes.
Click Cancel to return to the Group Authorizations screen without saving the
changes.
Deleting a Group
To delete a group, highlight the group name on the Group Authorizations screen and
click the Delete button at the bottom of the screen. The group will be deleted immediately.
Note: You cannot delete a group that has a user associated with it. The Administrator group
cannot be deleted.
Page 13
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
User Authorizations
The User Authorizations... option allows authorized users to define new users and
associate them with the appropriate groups.
• To configure user permissions, log on as an authorized user with Admin rights and
select Edit>User Authorizations to call up the screen shown in Figure 10.
Figure 10. User Authorizations Screen
The User Authorizations screen lists all current users along the left side and all existing
groups along the top. The Authorization Name shows the name of the user, followed by a
checkbox for each available group. A checkmark beneath a group indicates that the user is a
member of that group with access to all the features associated with the group.
Adding a User
To add a new user, click the New button at the bottom of the screen. The screen shown in
Figure 11 will be displayed.
Figure 11. New User Screen
•
•
•
•
•
•
Page 14
Enter a name for the user.
Enter a password for the user.
To confirm the password, re-enter it in the Retype Password field.
Select each of the groups in the Groups panel to which the user will belong.
Click Save to add the user.
Click Cancel to return to the User Authorizations screen without adding the user.
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Editing a User
To change a user’s password or change the groups the user belongs to, highlight the
user’s name on the list and click the Edit button at the bottom of the screen. A screen similar
to that shown in Figure 12 will be displayed.
Figure 12. Edit User Screen
•
•
•
•
•
To change the user’s password, enter a new password in the Password field.
To confirm the password, re-enter it in the Retype Password field.
Check or uncheck groups in the Groups panel to set the groups to which the user will
belong.
Click Save to save the changes.
Click Cancel to return to the User Authorizations screen without saving the changes.
Deleting a User
To delete a user, highlight the user’s name on the User Authorizations screen and click
the Delete button at the bottom of the screen. The user will be deleted immediately.
Page 15
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Configuration
When you select Configuration from the Edit menu, the main configuration screen (Figure
13) appears. This screen contains a series of tabs that provide access to the various
configuration functions.
Figure 13. Configuration Menu – Airport General Tab
•
To access a configuration category, click the appropriate tab at the top of the screen.
•
The Airport and Misc categories also provide secondary tabs that group similar
options under a common heading.
Page 16
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Airport Tab
The Airport tab (Figure 13) contains two sub-tabs: General and Runways.
General
The Airport>General tab contains several options unique to the airport location.
General
Airport Name
The name entered here will be shown at the top of the display.
ICAO Identifier
The four-letter ICAO airport identifier or three-digit airport identifier.
Magnetic Declination
The display map is oriented to True North; this option allows you to enter a
site’s magnetic declination, so that the strike locator is oriented to Magnetic
North. When a value is entered here, the strike locator will rotate on the screen
to a Magnetic North orientation. When entering a magnetic declination, you
must also specify East or West declination by selecting the East or West button.
Runways
The Airport>Runway tab (Figure 14) contains a single field for specifying the ID of the
runway where the lightning sensor is installed.
Figure 14. Airport Runway Tab
Runways
Runway
Enter the number/designation of the runway associated with the lightning sensor.
The value can consist of a 2-digit number from 1-36, or up to four text characters.
When a numeric value is entered, it can be followed by an optional auxiliary
designator (R or L, for example).
Page 17
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Map Tab
The Map tab (Figure 15) lets you specify the center point of the lightning display and set the
decay time for strikes.
Figure 15. Lightning Tab
•
•
•
Page 18
In the Center Point panel, enter the latitude and longitude of the location you
would like to set as the center of the lightning map.
In the Decay Time field, enter the number of minutes for a strike indicator to
remain on the screen. As the strike ages over this time period, it will change color.
When the decay time period has elapsed, the strike will be erased. The value
entered here will be reflected in the map key.
When done, click OK.
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Misc Tab
The Misc tab lets you specify the number of days to retain logs in the system before
deleting them, and set the system time.
General Tab
In the text box under the General tab (Figure 16), enter the number of days the system
should maintain log files before overwriting them. The value can be anywhere in the range of
4 days to 999 days.
Figure 16. Logs Tab
Page 19
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Time Tab
Use the Time tab (Figure 17) to set the GPS receiver as the time source for the software
or to manually enter the time and date. Use GPS Time should be selected in normal
operation; disable only if the GPS Receiver fails or is not installed.
•
Select Use GPS Time to obtain time and date data from the GPS Receiver.
•
To specify the time and date manually, uncheck the Use GPS Time box and enter
the date and time in the corresponding fields. To change the date, click the calendar
icon to call up a monthly calendar, then click the appropriate date. To change the
time, click within each time field and manually enter a value. This option will use
the computer’s built-in clock, which is less accurate than the GPS Receiver.
Figure 17. Time Tab
Page 20
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Port Configuration
The Port Configuration option (Figure 18) is used to specify the communication ports used
by the lightning sensor and GPS. It also provides the option of scanning a range of ports
periodically.
• In the Lightning Sensor Port field, enter the number of the port the lightning
sensor is connected to. Enter only the number; if the sensor is connected to
COM 1, for instance, enter “1”.
• In the Port field of the GPS panel, enter the number of the port the GPS is
connected to. This is a USB port, so the number is assigned automatically by the
operating system and will always be at least 1 greater than the number of physical
ports. To see the assigned port number, follow the steps below with the GPS
connected:
o Go to Start>Control Panel>Performance and Maintenance>System,
select the Hardware tab, then click Device Manager.
o On the device list, click the + sign beside the Ports (COM & LPT)
heading to expand it and show the list of serial ports.
o Note the port number for the GPS.
• The Scan Ports option initiates a periodic scan of serial ports to detect the GPS if
its port number has changed. This can happen if the GPS has been plugged into a
different USB port or if another USB device has been connected. In the Scan
Start Port field, enter the lowest USB port number (1 greater than the number of
physical ports). In the Scan End Port, enter the highest port number to scan. The
maximum is 255.
• When done, click OK to save the settings.
Figure 18. Port Configuration
Page 21
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Points of Interest
The Points of Interest option (Figure 19) on the Edit menu lets you add reference locations
to the map on the main display. Once entered, the names of the points of interest will be
shown on the main display at their specified locations.
Figure 19. Points of Interest Option
Adding a Point of Interest
To add a point of interest, click the Add button at the bottom of the Points of Interest dialog.
The screen shown in Figure 20 will be displayed.
Figure 20. Add Point of Interest Dialog
1. Enter the latitude of the desired reference point in degrees, minutes, and seconds
in the Latitude text boxes.
2. Enter the longitude of the desired reference point in degrees, minutes, and
seconds in the Longitude text boxes.
3. Enter a name for the point of interest in the Name text box. This is the name that
will appear on the main display.
4. Click OK to save the point of interest, or click Cancel to exit the dialog without
saving the point of interest.
Page 22
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Editing a Point of Interest
To edit a point of interest:
1. On the list of points of interest, highlight the name of the location you want to edit.
2. Click the Edit button at the bottom of the screen. The Add Item screen (Figure 20)
will be displayed.
3. Adjust the latitude, longitude, and name as needed.
4. Click OK to save the new values, or click Cancel to exit the dialog without saving
the changes.
Removing a Point of Interest
To remove a point of interest, highlight its name on the list and click Remove. The point of
interest will be deleted.
Logs Menu
The Lightning Display software records each strike detected, and stores the complete
data for one day in a daily strike log. If no lightning is detected, no log will be generated for
that day. The length of time that log files are maintained is set by the user via the
Edit>Configuration>Misc>Logs menu option. Log files older than the time set through that
screen are automatically deleted.
Viewing Logs
Clicking Daily on the Logs menu calls up an Open Log screen such as the one shown in
Figure 21.
Figure 21. Open Log Screen Example
Log files use the naming format: DLYStrike.yyyymmdd.log, where yyyymmdd
represents the date the data was recorded. In the example above, for instance, the file
DLYStrike..20090414.log contains strike data for April 14, 2009.
1. To open a log file, click the desired file to highlight it, then click Open.
2. You can view the file on-screen, or select Print to print the data log. When done,
click OK to close the window.
Page 23
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Data Format
The lightning sensor data format is described below.
Communications is RS232 9600 8N1
Output data format is : <STX><i d ><ddd><CR>(<id><ddd><CR>) . <cc ><ETX>
STX:
is the ASCI I Start-of-Text Character (02h )
id:
is the item designator from the table below
ddd :
is the value of the data item in the Item Format column in the table below
CR:
Carriage Return
cc :
checksum - summing all data between STX and “.”, then masking all but the
lower 8 bits.
ETX:
is the ASCII End-of-Text Character (03h )
Item
Designator
%I
Item Format
dmch
Field Width
(bytes)
4
%S
cccbbbrrr
9
%A
rrrbbb
6
Page 24
Item Description
System Status, where d is "F” = fatal fault ,”R" = recoverable fault, "P" =
O.K.
Display Mode m is transmitted as follows:
“A” Weather
“B” Noise Monitor
“C” Strike Test
“D” Demo
“E” Pilot Initiated Self-Test
Configuration data c is sent as 010:B4:B3:B2:B1:B0 where
Heading_Config
Synchro Stepper Serial
None
B4
HdgFormat1_lnput
1
0
1
0
B3
HdgFormat2_lnput
0
1
1
0
B2
Heading Flag Input Sense; 0 if a High level signal on Heading
Flag+ (pin P2-24) with respect to Heading Flag- (pin P2-25) indicates
Valid Heading
B1
Antenna. Mount 0=Bottom, 1=Top
B0
Spare
Heading Flag h is sent as 010:B4:B3:B2:BI :B0 where
B4
Heading Stabilization 1=Enabled
B3
Heading Flag Input 1=Valid
B2
Heading Valid 1=Valid
B1
Synchro Reference Flag 1=Valid
B0
Synchro Angle Flag 1=Valid
Heading Stabilization state defaults to last state when powered up.
Synchro Reference Flag and Synchro Angle Flag will he zero when
configured for Stepper or Serial heading input.
Transmitted once per message.
ccc=Range to strike ("001" - "200" NM) Cell mode (a value of 201 indicates
invalid); bbb=Bearing to strike, clockwise in degrees “000” - "359" deg).
rrr=Range to strike (“001 – “200” NM) Strike mode. This Item Designator
may appear from 0 to 40 times per message depending on thunderstorm
activity. Invalid Cell mode range indicates the strike is not displayed in Cell
mode view. In Noise Monitor Mode, ccc will always indicate 201 and rrr will
have a range of 001 – 400.
Test strike range and bearing. rrr=Range to strike ("001" - "200" NM);
bbb=Bearing to strike, degrees clockwise("000" - "359" deg). Transmitted
once per message block. Only transmitted when in Strike Test Mode.
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
%E
dd
2
%V
Xxxxxx
6
%T
ddddd
5
%B
%H
dddd
0
4
%D
14 lines
(24 columns
+CR)
350
%L
emmttbbb
variable
Fault code (“00” – “99”), more than one possible (%E for each code up to
5 codes), see table. Transmitted each message only when System
Status (%I) indicates fault or degraded operation.
X=”B”, xxxxx=S/W version string, padded on right with "spaces" if needed.
Transmitted at least 2 times per minute.
ddddd=”00000” – “99999”, number of triggers detected since power on.
Pressing "Clear" resets counter to “00000”. Used for installation verification
and troubleshooting.
Clear message indicates that the data buffers are cleared.
Aircraft heading x10 (0000 - 3599). Heading outside valid range indicates
heading not available or "flagged" (e.g., 9999). When configured for Stepper
heading, this message contains relative heading angle.
System Data Screen text requested by the host. The System data is sent in
addition to the standard communications block prefixed by its own STX and
followed by its own ETX. The System data screens may contain software
versions, environmental parameters or the fault log. One of the System Data
Screens is transmitted in response to a System Data Screen request.
BFG Logo - generally requested only once during the power up sequence
for display. The logo is a bitmap image of the BFG logo. e=Encoding type
character (always “1”), mm=Msg number, tt=Total messages, bbb=Number
of bytes of logo data in message, *=bbb bytes of logo.
A message is sent from the sensor once every two seconds. Each message includes at least
the sensor orientation and status. If strikes are detected, they are shown between the
orientation data and the status data. Up to 40 strikes may be included in a single two-second
message. If errors are detected, they will be included in the message as well.
Below is a sample of the sensor output data stream that includes a description of the data
immediately following the data.
%VB1.03
(Software Version, sent at least twice per minute)
%IPAG@
(Status = OK, Weather Mode)
------------------------ 2 seconds ---------------------------%H0000
(Sensor Orientation 0 - North)
%IPAG@
(Status = OK, Weather Mode)
------------------------ 2 seconds ---------------------------%H0000
(Sensor Orientation 0 - North)
%S026276026 (Lightning Strike = 26NM, 276 degrees)
%S026278026 (Lightning Strike = 26NM, 278 degrees)
%S027277027 (Lightning Strike = 27NM, 277 degrees)
%S025279025 (Lightning Strike = 25NM, 279 degrees)
%S027279027 (Lightning Strike = 27NM, 279 degrees)
%S201279031 (Invalid Lightning Strike = 31NM, 279 degrees; “201” indicates an invalid strike)
%IPAG@
(Status = OK, Weather Mode)
------------------------ 2 seconds ---------------------------%E16
(Error 16 – Antenna Fault)
Page 25
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Error Messages and Troubleshooting
The Model 6502 continuously runs a series of self-tests to check sensor operation and returns
error messages when a fault is detected. Any detected errors are identified by "E" and a twodigit number ("E00" during normal operation) in the sensor’s raw data output. Table 2 lists
all the possible error codes, along with the probable cause of the fault and possible corrective
action. In many cases, a persistent error will require returning the sensor to All Weather Inc.
for service.
Table 2. Model 6502 error codes
ERROR
PROBABLE CAUSE
CORRECTIVE ACTION
ERROR 01. Processor Fault.
Main processor
Continued operation is not possible.
Contact Field Service.
ERROR 05. Processor Fault.
Main processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 06. Processor Fault.
Main processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 07. Processor Fault.
Main processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 08. Processor Fault.
Main processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 09. Processor Fault.
DSP processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 10. Processor Fault.
DSP processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 11. Processor Fault.
DSP processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 12. Processor Fault.
DSP processor memory
Continued operation is not possible.
Contact Field Service.
ERROR 14. Processor Fault.
DSP processor
Continued operation is not possible.
Contact Field Service.
ERROR 15. Processor Fault.
DSP processor
Continued operation is not possible.
Contact Field Service.
ERROR 16. Antenna Fault.
Antenna or antenna wiring
Weather mapping is inhibited.
a. Check antenna wiring for opens and shorts.
b. Contact Field Service.
ERROR 17. Processor Fault.
No test strikes, antenna in
noisy location, or faulty
antenna
Weather mapping is inhibited.
a. Check antenna wiring for opens and shorts.
b. Fault will clear automatically if interference
subsides.
c. Contact Field Service.
Page 26
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Table 2. Model 6502 error codes
ERROR
PROBABLE CAUSE
CORRECTIVE ACTION
ERROR 18. Processor Fault.
Invalid test strikes, antenna in
noisy location, or faulty antenna
Weather mapping is inhibited.
a. Check antenna wiring for opens and shorts.
b. Fault will clear automatically if interference
subsides.
c. Contact Field Service.
ERROR 19. Processor Fault.
Main Processor or Antenna in
noisy location
Weather mapping is inhibited.
a. Fault will clear automatically if interference
subsides.
b. Contact Field Service.
ERROR 20. Configuration
Changed.
Antenna location (top/bottom,
determined by processor
wiring) changed since system
was last powered up.
This may occur the first time the system is powered
on in a new installation. Power the sensor off and
back on again. If the error persists, contact Field
Service.
ERROR 21. Processor Fault.
Main processor
Continued operation is not possible.
Contact Field Service.
ERROR 22. Invalid XYZ Input.
n/a
n/a
ERROR 23. Invalid Heading Ref.
n/a
n/a
ERROR 24. MIC KEY STUCK.
Mic key (inhibit line) has been
asserted for at least 60
seconds
Weather mapping is inhibited.
a. Contact Field Service.
ERROR 25 - 34. Processor
Fault.
Main processor
Continued operation is not possible.
Contact Field Service.
ERROR 35. Processor Fault.
Main or DSP processor
Continued operation is not possible.
Contact Field Service.
ERROR 36. Processor Fault.
Main or DSP processor
Continued operation is not possible.
Contact Field Service.
ERROR 40. Processor Fault.
Main processor
Continued operation is not possible.
Contact Field Service.
ERROR 41. Processor Fault.
Main or DSP processor
Continued operation is not possible.
Contact Field Service.
ERROR 42. Processor Fault.
Main processor
Continued operation is not possible.
Contact Field Service.
ERROR 43. Invalid request.
n/a
Message error will clear once processed
a. Excessive noise on communication lines,
check wiring.
b. If error occurs frequently, contact Field
Service
Page 27
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Table 2. Model 6502 error codes
ERROR
PROBABLE CAUSE
CORRECTIVE ACTION
ERROR 44 - 49. Serial
Communication.
n/a
Message error will clear once processed
a. Improper baud rate.
b. Excessive noise on communication lines,
check wiring.
c. If error occurs frequently, contact Field
Service.
ERROR 50. Illegal Serial
Heading Value.
n/a
Message error will clear once processed
a. Excessive noise on communication lines,
check wiring.
b. If error occurs frequently, contact Field
Service.
ERROR 51. Invalid Message.
n/a
Message error will clear once processed
a. Excessive noise on communication lines,
check wiring.
b. If error occurs frequently, contact Field
Service.
ERROR 52. Invalid Antenna
Change Request.
n/a
Message error will clear once processed
a. A request was received to change the
antenna mount to a location that does not
match the configuration jumpers. Request is
ignored.
b. If error occurs frequently, contact Field
Service.
ERROR 53 - 54.
Communications Buffer
Overload.
n/a
Message error will clear once processed
a. Excessive noise on communication lines,
check wiring.
b. If error occurs frequently, contact Field
Service.
Table 3 lists some common problems that may arise and the corrective action to take.
Table 3. Troubleshooting
PROBLEM
CORRECTIVE ACTION
Computer will not run
Check power cable to computer; make sure power switch is ON.
Computer runs, but no display
Check cables to display; make sure display power switch is ON
Display software does not start
automatically
Double-click AWI Lightning Display icon on desktop OR restart computer
Application runs, but no lightning data
Check all connections
Check radio status (refer to radio manual)
Check power to the lightning sensor
At lightning sensor:
Check lightning sensor status LEDs;
check radio lights inside lightning sensor cabinet
check AC power board, replace if faulty
If the problem persists, contact your local representative or AWI Customer Service.
Page 28
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Processor LEDs
The processor (housed within the enclosure) is equipped with a series of LEDs on its front
panel (see Figure 22) that can be used to monitor certain basic functions. Table 4 explains
how to interpret the LEDs.
DSP
Main
Serial
Figure 22. Processor front panel LEDs
Table 4. Processor LED functions
COMMUNICATION
LED
NORMAL OPERATION
FAILED OPERATION
DSP
1
ON
OFF
6
Toggles ON/OFF
when strike detected
Does not toggle ON/OFF
when strike detected
7
OFF
ON
8
Toggles ON/OFF
once per second
Stays ON or OFF
(does not toggle)
T
Reserved for future use
Reserved for future use
RX
Reserved for future use
Reserved for future use
TX
ON
(pulses when TX occurs) *
Stays OFF or ON
(does not pulse)
RX
ON
(pulses when RX occurs) *
Stays OFF or ON
(does not pulse)
MAIN
SERIAL
* Serial communication occurs every 2 seconds, causing LEDs to pulse rapidly. Due to transmission speed, LEDs may
appear not to change conditions during TX/RX operation.
Page 29
Thunderstorm/Lightning Sensor and Graphic Display
User's Manual
Maintenance
Periodic Maintenance
Equipment Required
Equipment required for periodic maintenance of the Model 6502 consists of:
• RTV 162 (as necessary)
Monthly Maintenance
No monthly maintenance is required with this sensor.
Triannual Maintenance
Perform the following maintenance tasks three times per year:
• Check the antenna for dents, cracks, or punctures.
• Remove all dirt and grease from surface areas using a soft cloth moistened with mild
soap and water.
• Check the sealant around the antenna base and mounting bolts, and reapply as
necessary (use RTV 162).
• Check all hardware for corrosion and ensure that all bolts and connectors are tight.
• Ensure that the cable connections are sound between the sensor and the display
station.
Annual Maintenance
Annual maintenance consists of performing the quarterly maintenance tasks.
Specifications
Measuring Range:
Internal Voltage:
Current:
Operating Temperature:
Relative Humidity:
Communication:
Mounting:
0-200 nautical miles
11-32 volts dc
0.82 A (maximum) @ 12 volts dc
0.38 A (maximum) @ 28 volts dc
-60 to +70° C
up to 100%
RS-485, 4800 baud
2½" pipe (2.875" O.D.)
Weight:
40 lbs. (18 kg)
Page 30
User's Manual
Thunderstorm/Lightning Sensor and Graphic Display
Warranty
Unless specified otherwise, All Weather Inc. (the Company) warrants its products to be free
from defects in material and workmanship under normal use and service for one year from
date of shipment, subject to the following conditions:
(a) The obligation of the Company under this warranty is limited to repairing or replacing
items or parts which have been returned to the Company and which upon examination
are disclosed, to the Company’s satisfaction, to have been defective in material or
workmanship at time of manufacture.
(b) The claimant shall pay the cost of shipping any part or instrument to the Company. If the
Company determines the part to be defective in material or workmanship, the Company
shall prepay the cost of shipping the repaired instrument to the claimant. Under no
circumstances will the Company reimburse claimant for cost incurred in removing
and/or reinstalling replacement parts.
(c) This warranty shall not apply to any Company products which have been subjected to
misuse, negligence or accident.
(d) This warranty and the Company’s obligation thereunder is in lieu of all other warranties,
express or implied, including warranties of merchantability and fitness for a particular
purpose, consequential damages and all other obligations or liabilities.
No other person or organization is authorized to give any other warranty or to assume
any additional obligation on the Company’s behalf, unless made in writing and signed by an
authorized officer of the Company.
Page 31