Download DS-Controller-Operation Manual
Transcript
DS Controller DS 1.4.2 External I/O Specification External Input Circuit Item Specification External Power Voltage 24 V DC ± 10 % Input Current 7 mA / 24 V DC ON/OFF Voltage • ON voltage: min. 18,0 V DC • OFF voltage: max. 6,0 V DC Insulation non-insulated External Connection Device • No-voltage contact point (minimum load about 5 V DC - 1mA) • Photoelectric - proximity sensor (type PNP) • PLC Transistor output (type PNP, open collector) • PLC Contact point output (minimum load about 5 V DC - 1mA) Note: When a no-contact circuit is connected to an external circuit, make sure that the leakage current is under 1mA when the switch is OFF or, it could cause faulty operation. External Output Circuit Item Specification Load Voltage 24 V DC*) Maximum Load Voltage 100 mA / 1 point 400 mA peak*) (all current) Recommended Load Voltage 20 mA / 1 point*) Leakage Current Max. 0,1 mA Insulation No-insulated External Connection Device • Miniature relay • PLC input unit (type PNP) *) Application for TD62084 Notes: • For all of the external outputs, the flywheel diode (D) is connected on the inside. • Take care when connecting because if the load short circuits or the current exceeds the maximum load current, this will cause a failure in the output circuit. Page 1-8