Download Runco Reflection VX-1000d Operating
Transcript
RS-232 Communications General Information Baud rate: 19200 (fixed) Bits: 8 No Parity All protocol in ASCII format RS-232 input connector pin numbers: TxD= Pin# 2, RxD= Pin# 3, GnD= Pin# 5 Command format (single command): command value (i.e. brightness 100). NOTE: A space (not an underscore) or comma may be used between the command and its value. Command string format: command,command value, command etc. (i.e. COMPOSITE,BRIGHTNESS 100,ANAMORPHIC,<CR>) NOTE: In between commands, a comma or space may be used NOTE: A carriage return must be used after each command or string. Other notes: • For command strings, a maximum of 255 characters can be used in a single string. • PARAMETER min/max refers to a function's minimum and maximum value range. Inputting values above or below their range may cause unpredictable (but not fatal) results. 23