6. COMMAND STRUCTURE LH SYSTEM CONTROL COMMANDS LIMITS HIGH This limits high command sets the overtravel limit switches so they are active high. For instance, the overtravel occurs when the input level is high. See the AP Command on page 6-24 to preserve the LH settings as the Power up/Reset modes. MODE AX - AS AA AM AA/CD QUEUE REQUIREMENTS Min (pf) Max (pn/cn) 1 1 1 1 1 1 Not valid Not Valid Custom ramp 1 1 1 Not Valid Example: Select the limit switch high true condition for the X axis. Enter: AX LH Example: Select a high true limit condition for the Z and U axes. Enter: AA LH,,1,,1; LL LIMITS LOW The LL command specifies that overtravel occurs when the limit input signal is low (active low). This is the factory default mode. See the AP Command on page 624 to preserve the LL settings as the Power up/Reset mode. MODE AX - AS AA AM AA/CD QUEUE REQUIREMENTS Min (pf) Max (pn/cn) 1 1 1 1 1 1 Not valid Not Valid Custom ramp 1 1 1 Not Valid Example: Select the limit switch low true condition for the X axis. Enter: AX LL Example: Select a low true limit condition for the Z and U axes. Enter: AA LL,,1,,1; PC68 User’s Manual 6-17