Download Installation Manual Wireless Touch Control Unit
Transcript
Positioning Of The Rf Touch And Rf Devices Power Supply And Wiring Requirements Please note: The radio signal range of the RF installation depends on the building construction, materials and position of all devices. Before final fixing the RF Touch we suggest that a communication test is performed to each actuator from the RF Touch when it is in the proposed installation location (See menu create and programming sections) Direct 230V Termination Power Supply Adapter Transmission of radio-frequency signals through various materials Wooden structures with plasterboard 80-95 % Brick wall 60-90 % Reinforced concrete 20-60 % 12V DC plug-in adapter (supplied) Fitting Metal plates 0-10 % 230V Supply A1 - Live (Brown) A2 - Neutral (Blue) (The centre termination is not required) Standard glass 80-90 % Double Insulated Ensure the electrical circuit is isolated prior to starting any electrical installation. Any electrical installation must be undertaken by a qualified electrician in accordance with the latest IEE Wiring Regulations. 8 Previous Contents Contents Forward 9