Download Manual - Kantronics
Transcript
See also: CMSG, CONNECT
CTRL {A | B} { OFF | ON | LONG | n}
(n=1-20)
immediate
This command causes the MT1200 to activate (or deactivate) the specified output line
(A or B) to the radio port as indicated. If A or B output is not specified, both outputs are
affected. For instance, to pulse the A output (CTLA on the schematic) 3 times, you
would give the command “CTRL A 3". You may optionally specify the number of times
to pulse the output (n), or to turn the output ON, or OFF. Each pulse on the output line
lasts approximately 100 ms (0.1 s). Specifying LONG results in one pulse of the output
line, lasting approximately 1.5 s. These output lines are open drain outputs and are
pulled to ground when active. For more information, see the section on “Connecting to
your Radio” in this manual.
Do not allow more than 200 mA of current in this circuit.
CWID [{EVERY | AFTER}] n
(n = 0 - 255)
default EVERY 0
Each increment specifies 1-minute intervals. A value of 0 turns the ID OFF. Setting a
value greater than 0 activates the ID under the conditions specified. If the optional
keyword “Every” is used, an ID will be sent every n minutes. If set to “After”, an ID will
be sent ONCE after the specified interval with no channel activity.
The string specified by the CWIDTEXT command will be sent in Morse Code, using
AFSK tones.
Some countries require all stations to ID in Morse code periodically.
See also: MYCALLl, CWIDTEXT
CWIDTEXT text
(0-15 characters)
default DE mycall
This command sets the text to be transmitted when the MT1200 performs an automatic
CWID. The text will be transmitted periodically as set by the CWID command.
See also: CWID
89