Download JetNet 4008f
Transcript
Coupling Port is responsible for data backup path recovery between two separate redundant Rings, and Control Port is for communicating control signal between “Coupler” switches. Note: The Super Ring Redundant ports, Coupling port and Coupling Control port must all be assigned to different ports. Enable Couple Ring Setting Enable/ Disable Description Factory Default Select the JetNet as “Coupler” None Setting Description Factory Default Coupling Port Select any port of JetNet to be Port 3 is enabled for Couple the “Coupling Port” Ring Select any port of JetNet to be Port 4 is enabled for Couple the “Control Port” Ring Coupling Ports Control Port Network Redundancy: Dual Homing Dual Homing provides an advanced redundancy network solution by connecting switches running in different redundant protocols (e.g. IEEE 802.1w Rapid Spanning Tree Protocol and Super Ring) to extend the network redundant coverage. Technology Overview Redundancy is achieved by connecting two ports from two separate switches using Super Ring protocol with two ports of Managed Switches using RSTP protocol (please see connection in Figure-DualHoming). An active link where data is transmitted is connected with one port in the switch. The other port connected with another switch is a hot standby link. Constantly monitoring the hot standby link and will switch over in seconds once the active link is disconnected or breaks. 3-24 Korenix JetNet 4500 Series Industrial Managed Ethernet Rail Switch User’s Manual