Chapter 4 IInstallation and Wiring
4.3.7 PAUSE Input
This input is enabled in the controller mode.
The PAUSE input is used to temporarily stop the operating slider / cylinder (operation
data is held). To resume the operation, switch the PAUSE input to the non-active
state and then activate the START input. When an operation is paused via the PAUSE
input, the READY output, MOVE output and END output will change their status as
follows:
Note
If the PAUSE input is active, operation
cannot be performed even when the
START input is activated.
Output Status During Pause
READY output: Switches from the non-active to active state
MOVE output : Switches from the active to non-active state
END output : Remains in the non-active state
■ Figure 4-17 PAUSE Input
A
START input
N.A
4 ms or more
A
PAUSE input
N.A
A
READY output
N.A
A
MOVE output
N.A
A
END output
N.A
10 ms or less
10 ms or less
Opposite the motor direction
Motor operation
Motor direction
A (active)
: ON
N.A (non-active): OFF
EZS/ EZC Series Controller EZMC36 USER MANUAL
4-15