Chapter 4 IInstallation and Wiring
4.3.17 T- UP Output
This output is enabled in the controller mode.
The T- UP output is used to indicate that a push-motion operation has been completed.
The T- UP output becomes active when a pushed condition is achieved inside the pushdistance range (Figure 4-27). If the pushed condition is not achieved, the cylinder
will move by the set range and the END output will become active when the movement is complete.
See 6.2, “Push-Motion Operation ”, on p. 6-5 for details on the push-motion operation.
■ Figure 4-27 T- UP Output ( pushed condition achieved )
A
START input
N.A
A
END output
N.A
4 ms or less
A
T-UP output
N.A
Push distance
Opposite the motor direction
Motor operation
Motor direction
A (active)
: ON
N.A (non-active): OFF
■ Figure 4-28 T- UP Output ( pushed condition not achieved )
A
START input
N.A
A
END output
N.A
4 ms or less
A
T-UP output
N.A
Push distance
Opposite the motor direction
Motor operation
Motor direction
A (active)
: ON
N.A (non-active): OFF
EZS/ EZC Series Controller EZMC36 USER MANUAL
4-23