We recommend the following steps after the consumption of 300 kg of pellets:
1.
Check both ash pans and the combustion chamber. Empty the ash from them and clean, if necessary.
2.
Check the burner grate. If you find ash or deposits there, clean the grate (including air holes).
3.
Check the bottom of the pellet tray. If dust has accumulated there clean it.
4.
Remove the cleanout top cover, remove the turbulators and clean them (repeat this step every month).
5.
Use only high quality wood pellets of a diameter from 6 to 10 mm and a maximum length of 30 mm.
Dataplates are located on the right side of the boiler and under the cover of the front panel, also on the right side of the burner.
Symbol
Description
Symbol
Description
PELLUX 100/20
Type of boiler
PBMAX 20.1
Type of burner
IP 21
Degree of protection
IP 21
Degree of protection
Q
Range of electric power
Q
Power Rating
PQN
Power consumption at nominal power
Pmax
Maximal electrical power
PQmin
Power consumption at minimum power
Pmin
Minimal electrical power
Tmax
The maximum operating temperature
Tmax
The maximum operating temperature
PMS
Maximum working pressure
M
Weight
V
Water storage capacity
wood pellets
The required pellet size
class (EN 303-5) Boiler class according to the EN 303-5
wood pellet
Serial number
Basic fuel
The CE marking
The CE marking
Sign electro recycling - waste
Sign electro recycling - waste
Sign indicating the need to read the
manufacturer’s information
Sign indicating the need to read the
manufacturer’s information
“The Clean Air Act 1993 and Smoke Control Areas”
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from
a furnace or from any fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area unless it is used in an
"exempt" appliance ("exempted" from the controls which generally apply in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England.
In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies
in Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been "authorised" in Regulations and that appliances used to burn
solid fuel in those areas (other than "authorised" fuels) have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act can be found here : http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements.
Pellux 100/20 and Pellux 100/30 have been recommended as suitable for use in smoke control areas when burning wood pellets.
The product is not intended for use by persons with reduced physical fitness/mental efficiency or without experience and knowledge, if they are not supervised or instructed by a person
responsible for their safety. Operation of the product by children is strictly prohibited.
We reserve the right to make product design changes and changes in the manual.