Stimulus Systems 8 Somatosensory stimulation 8.1 Electric stimulation There is 2-channel transcutaneous constant current electric stimulator inside the stimulator cabinet. The electrical pulse generator (LUCIUS & BAER GmbH) for the stimulators is located in a stimulus cabinet outside the magnetically shielded room (between the magnetically shielded room and the corridor wall).There is also a Neuromag stimulus I/O box identical to the one beside the stimulus computers. Connect the BNC cables from the stimulator to the corresponding output of the Neuromag stimulus I/O. Check that the triggers meant for the right and left sides are connected correctly. For example, use trigger 1 for left side (red) and trigger 2 for the right side (blue). Electrical stimulation can be generated internally with Acquisition Control software or externally with the stimulus PC. When generating the stimuli with the Acquisition software, the main computer sends the trigger directly to the Neuromag stimulus I/O box. If the sequence is generated with the stimulus PC, connect the PC trigger output to the Neuromag stimulus input with BNC cables. The Acquisition Control software generates simple stimulus sequences. To do that, select the “External Stimulus Sequence” in Settings and define the trigger channel and the inter-stimulus interval (ISI), i.e. the time difference between the previous trigger and the new one. For more complex stimulus sequences use the Presentation software (see sections 3.1 and 4.1). It is possible to adjust both the amount of the current and the duration of the electrical pulse with the knobs on the stimulator front panel (Figure 11). The stimulator generates only square wave pulses. The recommended pulse duration is 0.2 ms. The digital display shows the current intensity in mA Figure 11 The electrical pulse generator. for the left and right stimulators. Common current values for median nerve stimulation are 6-7 mA. Note that these values depend on the subject’s sensitivity as well as on the stimulated nerve (or skin). As a normal procedure, always start by stimulating at lower intensity and only then increase the value gradually. If a trigger pulse does not occur for a long time, for instance during a long break in the measurement, the current value on the display starts blinking and no current pulse is sent inside. This is a safety property of the stimulator and in this case follow the instructions: • • Start running the stimulus sequence. Turn the current to zero. 30