Stimulus Systems The virtual memory of the computer should always be off! If the computer loads stimuli from the virtual memory during an experiment, it causes delays of several hundred milliseconds. If the PC gives error messages and does not function properly you can reset the computer. First, try to restart the computer from the Start-menu or by pressing control-alt-del. If that does not work boot your computer from the front panel. Note that you have to remove the PCMCIA card located on the back panel of the PC when booting! Appendix A.1 illustrates the back panel of the stimulus PC together with the most important connections. 2.2 Stimulus Mac There is also a possibility of using a Macintosh Quadra 800 in stimulation instead of the PC. Mac’s IP address is 130.233.172.141 and its name in the network is “brain.hut.fi”. Nevertheless, it is strongly recommended to use the PC because the Mac is going out of use in the near future. This manual describes only the use of the stimulus PC. If you want to use the Mac, look for further information in the previous manual (Kimmo Uutela, 1995). 2.3 Mac/ PC AV switcher and distribution amplifier a.k.a. Mac/PC switch box The audio video switcher and distribution amplifier (Extron, SW VGA DA2 A) selects the source of image and sound as well as divides the video signal to both monitor and projector. The switch box is the flat box next to the monitor. Select the stimulus computer by pressing the corresponding button (Appendix A.2). 3 Software Presentation is the commonly used software with the stimulus PC. If you are using the stimulus Mac, use AVProbe which is based on MacProbe by Steven Hunt (see the previous manual by Kimmo Uutela, 1995). 3.1 Presentation Presentation (Neurobehavioral Systems, Inc.; http://nbs.neuro-bs.com) is a software system for stimulus delivery and experimental control. The operating system of the stimulus PC is Windows 98 because it enables Presentation to run with real-time priority during the experiments. With the 2000 or XP platforms this is not possible and problems could then appear in stimulus timing. Note that there are timing issues involved also with the hardware (see sections 4.3, 5.4, 6.5, and 7.4). In Presentation, experiments include all the information needed in stimulation (see section 3.1.2). An experiment consists of the settings made on the main control screen (Figure 1). On Experiment tab you can include scenarios in your experiment (sections 3.1.1 and 3.1.3). Scenario files are text descriptions of sequences of actions that are performed without interruption. Scenarios describe how the stimuli are presented (duration, order, interstimulus interval etc.). You can use templates and PCL files in your scenarios (sections 3.1.3 and 3.1.4). 5