Download Delta Electronics, Inc.
Transcript
Delta Electronics, Inc. ASIA DELTA ELECTRONICS, INC. TAOYUAN Plant 31-1 SHIEN PAN ROAD KUEI SAN INDUSTRIAL ZONE 333 TAOYUAN, TAIWAN R. O. C. PHONE: 886-3-361-6301 FAX: 886-3-362-7267 NORTH/SOUTH AMERICA DELTA PRODUCTS CORPORATION Sales Office P.O.BOX 12173 5101 DAVIS DRIVE RESEARCH TRIANGLE PARK, NORTH CAROLINA, 27709 U. S. A. PHONE: 1-919-767-3813 FAX: 1-919-767-3969 EURPOE DELTRONICS (Netherlands) B. V. Sales Office INDUSTRIEGEBIED VENLO NR. 9031 COLUMBUSWEG 20 NL-5928, LC VENLO THE NETHERLANDS PHONE: 31-77 324-1930 FAX: 31-77 324-1931 http://www.delta.com.tw VFD-PU02 Digital Keypad/Display Instruction Instruction DELTA ELECTRONICS, INC. VFD-PU02 VFD-PU02 Description of the Digital keypad VFD-PU02 LED Display Indicates frequency, voltage, current, user defined units, read, and save, etc. F H U VFD-PU02 JOG By pressing JOG key, Jog frequency operation. UP and DOWN Key Sets the parameter number or change the numerical data, such as the freq. reference. LEFT/RIGHT Key Selects the integer to be changed by the UP/DOWN keys. LEFT is to increase, and RIGHT is to decrease the setting value. RUN STOP JOG FWD REV EXTPU JOG MODE FWD REV RUN PU PROG DATA STOP RESET Operation Display Indicates the operation mode of the drive, such as RUN, STOP, JOG, FWD, REV, External Frequency, and Operation Mode. MODE Changes between different display mode. PU Switch the operation command source. PROG/DATA Sets different parameters and enter information STOP/RESET Stops AC drive operation and reset the drive after fault occurred. RUN Starts AC drive operation. FWD/REV Selects FWD/REV operation. © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED Model Number 2 VFD-PU02 Display Message Descriptions The AC drive Master Frequency. The Actual Operation Frequency present at terminals U, V, and W. The output current present at terminals U, V, and W. or By pressing to change the mode to READ. Press PROG/DATA for about 2 sec or until it’s flashing, then copy the data from AC drive to the digital keypad PU02. By pressing or to change the mode to SAVE. Press PROG/DATA for about 2 sec or until it’s flashing, then copy the data from the digital keypad PU02 to AC drive. The specified parameter setting. The actual value stored within the specified parameter. External Fault “End” displays for approximately 1 second if input has been accepted. After a parameter value has been set, the new value is automatically stored in memory. To modify an entry, use the or keys. “Err” displays, if the input is invalid. Communication Error. Please check with AC drive user manual (Chapter 5 Communication Parameter) for more details. © DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED 3