Download Delta Electronics, Inc.

Transcript
Delta Electronics, Inc.
ASIA
DELTA ELECTRONICS, INC.
TAOYUAN Plant
31-1 SHIEN PAN ROAD
KUEI SAN INDUSTRIAL ZONE
333 TAOYUAN, TAIWAN R. O. C.
PHONE: 886-3-361-6301
FAX: 886-3-362-7267
NORTH/SOUTH AMERICA
DELTA PRODUCTS CORPORATION
Sales Office
P.O.BOX 12173
5101 DAVIS DRIVE
RESEARCH TRIANGLE PARK,
NORTH CAROLINA, 27709 U. S. A.
PHONE: 1-919-767-3813
FAX: 1-919-767-3969
EURPOE
DELTRONICS (Netherlands) B. V.
Sales Office
INDUSTRIEGEBIED VENLO NR. 9031
COLUMBUSWEG 20
NL-5928, LC VENLO
THE NETHERLANDS
PHONE: 31-77 324-1930
FAX: 31-77 324-1931
http://www.delta.com.tw
VFD-PU02
Digital Keypad/Display
Instruction
Instruction
DELTA ELECTRONICS, INC.
VFD-PU02
VFD-PU02
Description of the Digital keypad VFD-PU02
LED Display
Indicates frequency, voltage, current, user
defined units, read, and save, etc.
F
H
U
VFD-PU02
JOG
By pressing JOG key,
Jog frequency operation.
UP and DOWN Key
Sets the parameter
number or change the
numerical data, such as
the freq. reference.
LEFT/RIGHT Key
Selects the integer to be
changed by the UP/DOWN
keys. LEFT is to increase,
and RIGHT is to decrease
the setting value.
RUN STOP JOG FWD REV EXTPU
JOG
MODE
FWD
REV
RUN
PU
PROG
DATA
STOP
RESET
Operation Display
Indicates the operation mode of the drive, such
as RUN, STOP, JOG, FWD, REV, External
Frequency, and Operation Mode.
MODE
Changes between different display mode.
PU
Switch the operation command source.
PROG/DATA
Sets different parameters and enter information
STOP/RESET
Stops AC drive operation and reset the drive
after fault occurred.
RUN
Starts AC drive operation.
FWD/REV
Selects FWD/REV operation.
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Model Number
2
VFD-PU02
Display Message
Descriptions
The AC drive Master Frequency.
The Actual Operation Frequency present at terminals U, V, and
W.
The output current present at terminals U, V, and W.
or
By pressing
to change the mode to READ.
Press PROG/DATA for about 2 sec or until it’s flashing, then copy
the data from AC drive to the digital keypad PU02.
By pressing
or
to change the mode to SAVE. Press
PROG/DATA for about 2 sec or until it’s flashing, then copy the
data from the digital keypad PU02 to AC drive.
The specified parameter setting.
The actual value stored within the specified parameter.
External Fault
“End” displays for approximately 1 second if input has been
accepted. After a parameter value has been set, the new value is
automatically stored in memory. To modify an entry, use the
or
keys.
“Err” displays, if the input is invalid.
Communication Error. Please check with AC drive user manual
(Chapter 5 Communication Parameter) for more details.
© DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
3