Download "user manual"
Transcript
System Delete ... deletes the selected file name from the assignment list Structure of the reference list (file PLCPROG.LST) It is divided into 3 areas: Number Area Degree of protection 1 ... 100 User area User 101 ... 200 Machine manufacturer Machine manufacturer 201 ... 255 Siemens Siemens The notation is carried out for each program by lines. Two columns are intended per line, which must be separated from each other by TAB, space or the ”|” character. In the first column, the PLC reference number must be specified, and in the second column, the file name. Example: Edit PLC alarm txt 1 | Welle.mpf 2 | Kegel.mpf This function can be used to insert or modify PLC user alarm texts. Select the desired alarm number using the cursor. At the same time, the text currently valid is displayed in the input line. Fig. 7-24 Editing the PLC alarm text Enter the new text in the input line. Press the Input key to complete your input and select Save to save it. For the notation of the texts, please refer to the Start-Up Guide. Data I/O 7-114 The window is divided into two columns. The left column is used to select the data group, and the right-hand column is used to select individual data for transfer. If the cursor is positioned in the left hand column, the whole data group is output when Read out is selected. If it is positioned in the right-hand column, only the selected file is transferred. You can use the TAB key to switch between the two columns. SINUMERIK 802D, 802D base line 6FC5 698-2AA00-0BP3 (11.03) (OP-T)