Download LightSYS Installation and Programming Manual
Transcript
Installing Bus Devices Wiring RP128EZ01 to the Main BUS Wiring RP128EZ01 to BUS Zones Expanders Notes: When connecting RP128EZ01 to a BUS Zone Expander wire the RP128EZ01 wires to the relevant BUS zone expander's terminals marked as TO DEVICE. 3. Wire the RP128EZ01 zone wires, Black and White, to the detector's terminals according to the required termination. Notes: The Black and White wires are equivalent to zone input terminals in the LightSYS. Completing the Installation To complete the installation 1. Mount the back panel to the wall using affixing screws 2. Connect the system to the mains power Note: If no back tamper is connected set SW1-4 to ON position to avoid tamper alarm 3. Close the front cover and close the locking screw 4. Upon completion of LightSYS bus device installation, module wiring, and DIP switch and jumper setting, proceed to Chapter 4 Installer Programming and Chapter 5 Using the Installer Non-Programming Menus Page 49