Download LightSYS Installation and Programming Manual

Transcript
Installer Programming
Quick Keys
Parameter
Default
 
Audible Proximity Tamper No
Range
Yes/No
This parameter relates to the bus siren.
YES: A proximity anti approach violation will activate the siren.
NO: A proximity anti approach violation will not activate the siren and
will be regarded as trouble by the system.
 
Siren Auxiliary = Tamper
No
Yes/No
This parameter relates to the bus siren.
YES: A siren auxiliary trouble will be regarded as tamper alarm by the
system.
NO: A siren auxiliary trouble will be regarded as trouble by the system.
 Labels
The System Labels menu enables you to modify the labels displayed by the LCD that identify
the system and partition labels. For changing labels from the keypad refer to page 52.
System: Labels
Quick Keys
Parameter
Default
Range

System
Security System
Any 16 Characters
Edit's the global(system label)
 to

Partitions 1 through 4
Partition 1 through
Partition 4
Any 16 Characters
 Sounds
The Sounds menu contains parameters that enable you to set the sound(s) that will be
produced after the following system events.

Tamper Sound
Sets the sound(s) produced by a Tamper violation of a keypad and/or an
expansion module, as follows:
 Silent — Produces no sound
 Bell (External Siren) Only
 Buzzer (Keypad Piezo) Only
 Bell + Buzzer