Download PPM ViaLite Quick Start Guide
Transcript
www.vialite.com PPM ViaLite Quick Start Guide This quick start guide is intended as an information summary, the relevant equipment handbook should always be treated as the master document. Initial Inspection Unpack and inspect the equipment as soon as possible. If there is any sign of damage or any parts missing, do not install the equipment before seeking advice from PPM or your local agent. The equipment received should match the delivery note that is shipped with the equipment. If there are any discrepancies, contact PPM or your local agent. Electrical Safety ViaLite LPS-M and LPS-R Power Supply Units are Safety Class 1 products (having metal case directly connected to earth via the power supply cable). When operating the equipment note the following precautions: • • • Hazardous voltages exist within the equipment. There are no user serviceable parts inside, and the covers should only be removed by qualified technician. The equipment does not have a mains isolating switch. Equipment must be installed within easy reach of a clearly labeled dual pole mains isolation switch. Ensure that fuses of the required rated current and of the specified type are used. Fuse information is shown on the rear of the module and in the handbook. ESD Precautions Precautions for handling electro-static sensitive devices should be observed when handling all ViaLite modules. Technicians should ensure that they use effective personal grounding (i.e. ESD wrist strap etc..) when servicing the equipment. Any equipment or tools used should be grounded to prevent static charge buildup. Good practice should be observed at all time for reference see relevant standards. EN 61340-5-1, “Protection of Electronic Devices from Electrostatic Phenomena – General Requirements Optical Safety The ViaLite RF Transmitter modules contain laser diode sources operating at 1290nm to 1613nm. These devices are rated as EN60825-1:1994 as CLASS 1 radiation emitting devices. When operating the equipment note the following precautions: • • • Never look into the end of an optical fibre directly or by reflection either with the naked eye or through an optical instrument. Never leave equipment with radiating bare fibres – always cap the connectors. Do not remove equipment external covers when operating. Optical Connectors and Fibres Ensure that all mating connectors are matched types. All PPM FC/APC equipment uses narrow key FC/APC connectors, these are not compatible with wide key FC/APC. Optical connectors MUST be cleaned before use. Most performance issues are due to dirty fibres. - Peel the plastic cover from an unused “N” cleaning pad. - Hold the connector between your thumb and forefinger Clean the connector using firm pressure by swiping in a pendulum motion through each segment of the “N” shape, following the diagram - Do not swipe over the same space twice. For more details please read the cleaning instruction which accompanies the connector cleaning kit. Details can also be found on the CD supplied with your equipment. To connect FC/APC optical connectors, remove the dustcaps and align the white ceramic centre ferrule on the cable connector with the mating receptacle. There is a key (lug) on the side of the ferrule, which must match the keyway (gap) in the receptacle shroud. When they are aligned, gently push the plug home and finger tighten the knurled collet nut onto the threaded receptacle. Disconnection is the reverse of connection; replace the dustcaps on both the receptacle and the cable plug. Only connect FC/APC cable to FC/APC modules Locate connector key Align key and keyway To connect E2000 optical connectors, gently push the plug into the E2000 adapter until a click is heard and the connector locks. To disconnect, depress the lever at the rear of the connector and withdraw the connector. The protective cover automatically engages and disengages, when inserted or removed. Minimum Bend Radius of a simplex patch cable is typically 30mm, at this radius there will be a very small increase in loss due to the bend (~0.05dB) Connecting and Disconnecting RF Connectors This product uses a range of RF connectors. Please ensure that RF connections are made with correctly matched connectors and cable impedances. Failure to do so may result in damage to the connectors and loss of performance. SMA RF connectors should only be connected with a calibrated SMA torque spanner. Lxx-QS-HB-1 Vialite Quick Start Guide Page 1 CR2724 ViaLite quick start guide www.vialite.com Installation 19 Inch Rack Installation The ViaLite 19” Rack Case is designed to fit 19” cabinets. Two options are available that occupy a height of either 1U or 3U. The Rack is provided with flanges for mounting to the cabinet. The 3U Rack Case must be used with at least one plug-in LPS Power Supply Module. The rack backplane contains 15-way D-type data connectors for each module position. This provides user access to data and voltage feed outputs from relevant modules. The pin-outs of these connectors are given in the following section. There is also a common alarm concentrator 25-way connector providing access to alarm and monitoring information from all modules. Power Supply Installation The 1U rack and outdoor cabinets are supplied with power supplies pre-installed. The 3U rack LPS-M/R plug-in modules are installed by simply sliding them into either of the two right hand positions, identified by a vertical line on the Rack Backplane PCB in position 9 or 10. Once the module is pushed fully home, tighten the corner screws, which hold the unit onto the front rails of the rack case. If the equipment is to be operated in dual redundancy mode, one Main Power Supply (LPS-M) and one Reserve Power Supply (LPS-R) will be required. The location of each is not critical. Installation of Plug-in Modules All ViaLite plug-in modules are hot-swappable, so it is not necessary to power-down the rack before inserting a module. Simply slide the module along the guides ensuring that it does not foul the adjacent units. When the module is pushed fully home, tighten the upper and lower screws on the module front panel. Connections are made at the rear of the unit, through the void at the rear of the rack case. It is advised that all unused slots be fitted with blanking panels. These are designed to fit the 7HP card slots used in either PPM’s 1U or 3U racks. They prevent accidental/unwanted access and the ingress of dust. When operating RF fibre optics links the ideal operating input power is dependent on the end users system. However in all cases there will be the desire to achieve the optimal SINAD. At low signal power this will be dominated by thermal noise and at high signal powers it will be dominated by distortion products. Typically a good quality signal can be obtained by operating the link at a composite input power 10-20dB below the fibre optics link’s P1dB specification level (see handbooks). Hot swappable modules Fixing screw top Slot 1-7 General Purpose modules Blanking panel Fixing screw bottom Slot 8 General purpose, Alarm concentrator or SNMP modules Rack summary connector Module rear connectors Slots 9-10 Power supply modules Summary alarm DIP switched Summary alarm connector PSU power connection IEC60320/C13 Module RF and optical interface ViaLite user manuals ViaLite OEM Module LRx-xM-HB All OEM modules ViaLite System User Manual Lxx-HB 19" chassis 3U and 1U version single module converter sleeve all power supply options (24V/48V/108-240V) ViaLite SatCom Links User Manual LRx-L-HB LRx-Lx (950MHz to 2150MHz) L Band LRx-Bx (10MHz to 200MHz) IF Band ViaLite Wideband Links User Manual LRx-R-HB LRx-Nx (10MHz to 1GHz) LRx-Rx (2kHz to 1.5GHz) LRx-Sx (10MHz to 3GHz) LRx-Wx(10MHz to 4.2GHz) including digital channel option Lxx-QS-HB-1 Vialite Quick Start Guide ViaLite DVB-T Link User Manual ViaLite Low Frequency Timing Module Handbook ViaLite Serial Digital Fibre Modem User Manual ViaLite Ethernet Link User Manual ViaLite SNMP Network Monitoring Module User Manual ViaLite Metro GPS User Manual ViaLite RF GPS Link User Manual ViaLite Digital GPS Link User Manual ViaLite Redundancy Switch User Manual ViaLite RF Splitter and Combiner User Manual ViaLite Alarm Concentrator User Manual ViaLite Fibre Optic Connector Cleaning Guide LRx-D-HB LRx-T-HB LSX-x2-HB LSX-E2-HB LRC-HB Metro-GPS-HB LRx-G-HB LSx-HB LRS-HB LRD-HB LAC-HB 72793-HB All manuals are available on CD Rom or from www.vialite.com Page 2 CR2724 ViaLite quick start guide www.vialite.com Rack Summary Pinout Pin Rack summary Pin Rack Summary 1 2 3 4 5 6 7 8 9 10 11 12 13 Summary Alarm PSU 2 Secondary Alarm PSU 2 Primary Alarm Module 2 Secondary Alarm Module 4 Secondary Alarm Module 6 Secondary Alarm Module 8 Secondary Alarm Module 2 Primary Alarm Module 4 Primary Alarm Module 6 Primary Alarm Module 8 Primary Alarm +12V from rack Ground 14 15 16 17 18 19 20 21 22 23 24 25 PSU 1 Secondary Alarm PSU 1 Primary Alarm Module 1 Secondary Alarm Module 3 Secondary Alarm Module 5 Secondary Alarm Module 7 Secondary Alarm Module 1 Primary Alarm Module 3 Primary Alarm Module 5 Primary Alarm Module 7 Primary Alarm +12V from rack Ground Note: Colour indicates relevant connector drawing 1 13 1 3 14 25 Summary Alarm: View looking into connector Connector Type: 3 pin, 2.54mm Molex KK Rack summary: View looking into connector D-Type connector (DB-25) Summary alarm pinout Pin Summary Alarm 1 2 3 Normally open Common Normally closed Note: Colour indicates relevant connector drawing Note: Ensure that rear DIP switches are appropriately set to “Fitted” and “Not Fitted” cards for correct summary alarm operation. RF Module Input/Outputs Levels • RF inputs and outputs should not be exposed to DC voltage levels in excess of ±36V. • Absolute maximum no damage RF input level is +13dBm (some unit will tolerate more, see handbook). • Absolute maximum no damage RF level applied to an RF output is +13dBm. Some transmitter modules are pre-configured to have a DC voltage present on the RF input connector, to drive low noise amplifiers and similar equipment. Check module handbook and description for more details. Receiver modules: All receiver modules will create a 1-2Vpeak DC transient from the RF output at start up into a 50Ω load (approximately 5V into a 1MΩ load). This may cause failure in some very sensitive spectrum analyzers or similar equipment. All modules have AC coupled inputs and/or outputs and will be sensitive to large transients (>5V) applied to either input or output. This may result in permanent damage to the units, particularly to low frequency units. Contact PPM for more details. Module Pin Outs Rack Mounted Modules Pin RF module Switch* Ethernet * Alarm Concentrator 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Not used RS422/485 Data + RS422/485 Data RS232 Data Alarm Output +12V from rack External Feed Ground Not used Not used Digital Ch Disable RTS_485 Analogue Monitor External LNA Feed Ground Control Control Control Control Alarm Output +12V from rack Not used Ground Not used Not used Not used Not used Not used Not used Ground RJ45-1 orange/white RJ45-3 green/white RJ45-5 blue/white RJ45-7 brown/white Not used Not used Not used Not used RJ45-2 orange RJ45-6 green RJ45-4 blue RJ45-8 brown Not used Not used Not used RS232 Data Output Remote 1 Alarm Remote 2 Alarm Remote 3 Alarm Alarm Output +12V from rack Remote PSU Alarm Ground RS232 Data Input Remote 4 Alarm Remote 5 Alarm Remote 6 Alarm Remote 7 Alarm Remote PSU Alarm Ground Pin Serial Digital – 2 channel Serial Digital – 3 channel SNMP / Splitter SNMP alarm extender*/** 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 RS422/485 output+ RS422/485 outputRS232 / TTL Data output Rx Optical Detect Alarm Output +12V from rack Not used Ground RS422/485 input+ RS422/485 input RS232 / TTL Data input Tx Optical Detect Alarm Output Not used Ground RS422/485 output1+ RS422/485 output1RS422/485 output2+ RS422/485 output2Alarm Output +12V from rack Not used Ground RS422/485 input1+ RS422/485 input1 RS422/485 input2+ RS422/485 input2 Alarm Output Not used Ground Not used Not used Not used Not used Alarm Output +12V from rack Not used Ground Not used Not used Not used Not used Not used Not used Ground Frame 2 Alarm 1 input Frame 2 Alarm 2 input Frame 2 Alarm 3 input Frame 2 Alarm 4 input Frame 2 Alarm 5 input Frame 2 Alarm 6 input Frame 2 Alarm 7 input Frame 2 Alarm 8 input Ground Frame 2 PSU Alarm 1 input Frame 2 PSU Alarm 2 input Not used Not used Not used Ground Connections in Blue are optional and only available on some types of module * Units supplied with custom cable for use in ViaLite system ** Optional custom cable available for use in ViaLite system Note: Colour indicates relevant connector drawing Lxx-QS-HB-1 Vialite Quick Start Guide Page 3 CR2724 ViaLite quick start guide www.vialite.com 8 1 5 1 15 9 15 11 Rack rear module: View looking into connector D-Type connector (DA-15) SNMP module alarm extender/programming: View looking into connector D-Type high density connector (DE-15) OEM modules Pin RF module TX * RF module RX * Serial Digital – 2 channel* 1 2 3 4 5 6 7 8 9 10 11 12 13 14 RS422/485 input+ Not used RS422/485 input Not used Alarm Output FSK disable +12V Power Ground Fuse voltage monitor RS232 Data input Ground LNA feed monitor External LNA Feed Analogue Monitor Not used RS422/485 output+ Not used RS422/485 outputAlarm Output FSK disable +12V Power Ground RS232 Data output RTS Ground FSK detect Not used Analogue Monitor RS422/485 input+ RS422/485 output+ RS422/485 input RS422/485 outputAlarm Output RTS RS485 +12V Power Ground RS232 / TTL Data output RS232 / TTL Data input Ground Tx Optical Detect Not used Rx Optical Detect Note: Colour indicates relevant connector drawing 2 14 1 13 Shielded Remote module: Looking into connector Connector Type: Lemo 1B 8-pole OEM module: Top view, 14 pin header Connector Type: Molex (C-Grid III), dual row Shielded remote modules Pin RF module TX RF module RX Serial Digital– 2 channel ** Serial Digital– 3 channel ** 1 2 3 4 5 6 7 8 Alarm Output RS232/422/485 input+ RS422/485 input Ground Power FSK disable LNA feed monitor Analogue Alarm Output RS232/422/485 output+ RS422/485 output Ground Power FSK disable FSK detect Analogue Monitor Alarm Output RS232/422/485 output+ RS422/485 output Ground Power RS232/422/485 input+ RS422/485 input RTS RS485 RS422/485 output2+ or RS422/485 input2+ RS422/485 output1+ RS422/485 output 1Ground Power RS422/485 input1+ RS422/485 input 1RS422/485 output2- or RS422/485 input2- Note: Colour indicates relevant connector drawing Connections in Blue are optional and only available on some types of module * Units supplied with custom cable for use in ViaLite system ** Optional custom cable available for use in ViaLite system Front Panel Indicators The following table shows the operation of the front panel LEDs: RF Transmitter, RF Receiver, Switch, Splitter and Serial digital modules Power LED (RF modules) Off Green Red Power LED (Switch, Splitter and Serial digital modules) Unit Off Unit OK NA Unit Off Unit OK Internal Fault Status LED (LRT modules) Status LED (LRR modules) Switch Position LED (LRS modules) Status LED (LSX modules) Unit Off Laser OK Laser Failed Unit Off Link OK High optical Loss RF Port Isolated RF Port Connected NA No traffic Traffic present NA Alarm concentrator and SNMP modules Off Green Red Power LED (ALL modules) Unit Off Remote LED (Alarm Concentrator) Unit is Off Unit OK Internal Fault ACM Link OK No valid ACM link Power LED Link status LED (Fibre port ) Unit Off Link established (steady) Remote fault (flashing) Remote LED (Alarm Concentrator) Unit Off OR No valid ACM link Remote Module OK Remote Module Fault Status LED (SNMP module) Configuration mode Link status LED (Copper port) Unit Off Link established RX/ACT LED (Either port) No traffic Traffic present Normal operation NA Ethernet Off Green Unit Off Unit OK Power supply modules Off Green Amber Red Fault LED PSU okay or Unit OFF NA NA Internal Fault Over Temp LED PSU okay or Unit OFF NA internal temperature >55°C NA +12V LED Internal Fault or Unit OFF PSU okay NA NA PULSE POWER AND MEASUREMENT LTD., 65 SHRIVENHAM HUNDRED BUSINESS PARK, SWINDON, SN6 8TY, UK. TEL: +44 1793 784389 FAX: +44 1793 784391 EMAIL: [email protected] W EBSITE : WWW.PPM.CO.UK Lxx-QS-HB-1 Vialite Quick Start Guide Page 4 CR2724