Download User Manual - TR Electronic
Transcript
Parameterization and configuration 7.1 Overview Configuration Operating parameters *·Length Features PNO Class 1 Page 22 - Code sequence 16 bit IN PNO Class 1 Page 23 - Code sequence 32 bit IN - No measuring system scaling, the measuring system has the base resolution according to the nameplate - 16 byte diagnosis data - Code sequence - Code sequence PNO Class 2 Page 24 - Class 2 functionality - Scaling function 16 bit IN 16 bit OUT - Total measuring range - Code sequence PNO Class 2 Page 26 - Class 2 functionality - Scaling function - Measuring system scaling is possible - Preset adjustment via the bus - Code sequence 32 bit IN 32 bit OUT - Total measuring range - Code sequence TR-extended 32 Bit Page 28 - Class 2 functionality - Scaling function 32 bit IN 32 bit OUT - Diagnostic alarm - Measuring system scaling possible - Preset adjustment via the bus - Code sequence - Preselection of the values for the external Preset inputs, depends on the type of measuring system - Total measuring range - Preset value - Code sequence TRextended+Speed 32 Bit Page 31 - Class 2 functionality - Scaling function - Diagnostic alarm - Total measuring range - Preset value - Speed resolution 32 bit IN 16 bit IN 32 bit OUT - Measuring system scaling possible - Preset adjustment via the bus - Code sequence - Preselection of the values for the external Preset inputs, depends on the type of measuring system - Speed output * from the bus master perspective © TR-Electronic GmbH 2007, All Rights Reserved Printed in the Federal Republic of Germany 08/08/2007 TR - ELA - BA - GB - 0001 - 05 Page 21 of 50