6. PARAMETER DESCRIPTION (11) Menu N: Loop Test Setting items Menu N contains items that are relevant to loop testing. [N31: Test DIO (O)] Setting for the DIO terminal condition during testing This parameter sets the condition of the DIO terminal during loop testing. Setting is possible when “Test” has been selected for N10: Test Mode. [N10: Test Mode] Setting for loop test execution Setting Function Normal No execution of loop testing. Test Loop testing is started Setting T0641.EPS IMPORTANT Function Input mode Must be set when N32: Test DIO (I) is used to display the condition of the DIO terminal. Open (Off) DIO terminal in Open (Off) condition Closed (On) DIO terminal in Closed (On) condition T0643.EPS (1) Test output has priority over flow rate measurement signals. When carrying out flow rate measurements, be sure to always return to “Normal”. (2) Upon entry to the Test Mode, all output terminals will simultaneously adopt test condition. (3) “Normal” will be restored when the power is turned off or when 30 minutes have elapsed since entry to Test Mode. (4) In Test Mode, the warning 83: Fix Cur Wng will be displayed as a warning message. (For more details, refer to Section 6.5 Alarm Functions.) [N32: Test DIO (I)] Display for DIO terminal condition during testing This parameter is used to display the condition of the DIO terminal. Setting is possible when “Test” has been selected for N10: Test Mode. Setting Closed (On) DO terminal in Closed (On) condition Pulse Outputs pulses as were specified with Menu E.* DIO terminal in Short condition [P10: Key Code] Parameter of the display restriction This parameter restricts access to the Service Mode. NOTE Write Protect function The parameters P20 through P23 are set when using the write protect function. Specifically, this function responds to a hardware switch or the setting of a software password, and it protects parameters from being overwritten. If the hardware switch is set to “Protect”, it will not be possible to overwrite parameters; furthermore, this condition will be maintained until the switch is set to “Enable”. For more details regarding hardware switch settings, refer to Section 10.2.2: Setting of Write Protect Switch. Function DO terminal in Open (Off) condition Short (12) Menu P: Parameter Protection items Menu P contains items that are relevant to write protection and passwords. [N30: Test DO] Setting for DO terminal condition during testing This parameter sets the condition of the DO terminal during loop testing. Setting is possible when “Test” has been selected for N10: Test Mode. Setting DIO terminal in Open condition T0644.EPS [N11: Test Output Value] Setting for test output values During loop testing, current output (4 to 20mA), totalization, and pulse will be output in accordance with this parameter’s setting, and values can be set when “Test” has been selected for N10: Test Mode. With multiple ranges or when performing forward/ reverse flow measurements, setting should be done using a percentage of the maximum range. Open (Off) Function Open T0642.EPS *: If the pulse scale is 0 pps or there is a pulse setting error, the DO terminal is “Open (Off).” [P20: Write Protect] Setting of password to release the write protection function This parameter is used to indicate whether or not write protection is currently on. 6-34 IM 01E20C02-01E