Download Click here for full Annexe on system from Singulus

Transcript
SINGULUS MASTERING International GmbH
Document number: 051006 AM Direct Annex
Clean Dry Air
SCU 1101/00
When using liquids (especially chemicals) the connection (Inlet
CDA) must be connected to a ctinuous supply of CDA. This
maintains an overpressure in the drive shaft bearing to protect
against liquid ingress.
Recuired supply: 2 – 5 l/min.
Drain
SCU 1101/00
Standard “GF” connection: 1¼”/ 32mm.
The drain outlet must drain to a chemically compatible drain or
drain store.
Connections
9.7
Oven requirements
Electrical power
OVM 1101/00
230, VAC ±10%
50Hz/ 60Hz
1-Phase
Neutral
Protective earth
Power consumption: 1.400 Watt (during heating)