Download Operation Manual - Bosch Security Systems
Transcript
ALLPLEX Access Easy Master Controller Panels Admin | en 135 NOTICE! When the Door Strike Timer is set to 0, and a valid card is presented at the Reader, the door i T becomes unlocked (View Activity shows Door Unlocked) until the same card or another valid card is presented at the Reader, only then the Reader will go back to locked mode (View Activity shows Door Locked). Presenting an invalid card will not change the status. View Acivity will only show Invalid Card. Door Strike For the Output device, such as Door Strike, though it is pre-defined, user can still change the default address to other available addresses within the same Reader board, should the original output relay is defective. To allocate an Output Address for Door Strike, select Output for Source, else select None. After allocating Output to Source, select an Address for it. The default Address is 1. The Address can be chosen from a selectable range. Output It defines the physical output on the Reader board. The output channels are applicable for Door Strike, Door Forced Alarm Output, Door Held Alarm Output and Invalid Card Output. Output channel assignment for devices connected in relation to the Reader is selectable within the spare Output channels of the card. User can disable the Output channel by selecting None. None This setting will disable the Output channel. NOTICE! i T 16.3.5 Address for Door Strike is selectable only to within the Card's spare Output channels. Door Forced Alarm Output, Door Held Alarm Output and Invalid Card Output is selectable only within the user programmable 32 outputs. Door Input Settings (For Entry Reader, Entry and Arm/Disarm Reader) A screen of the Door Input Settings page is shown in the section Door Output Settings. The Access Easy Controller has the capability to support a maximum of 16 wiegand card readers, 64 input (I) monitoring points, and 64 relay output (O) points.Of the 64 I/Os, only 32 Inputs and Outputs are user programmable, the other 32 I/Os are assigned to the Readers. The addresses for Input devices (Request-to-Exit device and Door Contact) connected in relation to the Reader, are pre-defined and cannot be changed. The following is the list of hardware to configure: X Request-to-Exit Device, X Door Contact, X Door Forced Open Alarm delay duration, X Pre-alarm Warning before door held open alarm. Request-to-Exit Device To allocate an Input Address for Request-to-Exit Device, select Input, else select None. The Address for Request-to-Exit Device is fixed and cannot be changed. Robert Bosch (SEA) Pte Ltd Software Manual Ver 1.0.1 | 2012.10