Download TG-300 Installation Guide
Transcript
A1.3 TERMINAL STRIP PIN ASSIGNMENTS Terminal Strip Pin 1 STC 2 STC Definition Supervisory Relay Trip output for programmable trouble conditions. (N.O.) Connects To 24-hour trip zone input on host C/C. Status LED Reference Function Enables transmission of programmed supervisory trouble code: When fault condition occurs: ♦ - AC Power LED OFF STC LED Flashes 1 time. AC Power Fail (ACFC). AC failure detected at 102 VAC. ♦ Low/Missing Battery Condition (LBC) due to: - Low Battery detected at 11.6 VDC. STC LED Flashes 2 times. ♦ Line Fault Condition (LFC) due to: - Improper Telco voltage (LFC) ≤ 18 VDC. STC LED Flashes 3 times. ♦ No Service Condition (NSC) due to: - Received Signal Strength ≤ -114 dBm. STC LED Flashes 4 times. ♦ Radio Communications Failure (RFC) due to: - RFC1- Failure to receive Link Request Ack after 3 attempts. OR RFC2- Failure to receive Link Termination Ack after 2 attempts. STC LED Flashes 5 times. ♦ Loss of Telguard Dial Tone Voltage (DTF) due to: Improper dial tone voltage. ≤ 35 VDC. 2 - BATT Telguard Battery negative terminal. 3 + BATT (12 V) Telguard Battery positive terminal. 5 BLANK 6 AC Telguard backup battery Provides 24 to 72 hour battery stand-by for Telguard depending on battery capacity provided. Not Used N/A Not Used AC power input. 16.5 VAC 40 VA. 120 VAC 60Hz unswitched circuit. 7 AC 56018803 STC LED Flashes 2 times when battery is low or missing. None Provides primary operational power to Telguard and battery charging circuit. Page 24 STC LED Flashes 6 times. AC Power LED ON when AC is normal. OR AC power LED OFF And STC LED Flashes 1 time when AC is low or missing. © 2000 Telular Corporation