F8913D User Manual 4.4.3.9.34 Set device whether RF data output the serial port Note:This command parameter don’t save in flsah. It is used to close the RF data output the serial port. Send query command: FE 01 21 2B 21 2A SOF Length Command Data FCS FE 01 21 2B command (1 byte) 2A 21 Respone to query command: FE 03 61 2B 21 01 00 69 SOF Length Command Data FCS FE 03 61 2B command (1 byte) Respone value (2 bytes) 21 01 00 69 Data Description: ( little-endian) Respone value: 00 00 = Not output 01 00 = Output Send set command: FE 03 21 2B 21 01 00 29 SOF Length Command Data FCS FE 03 21 2B command (1 byte) parameter value (2 bytes) 21 01 00 29 Data Description: ( little-endian) Parameter value: 00 00 = Not output 01 00 = Output Default :00 00 Respone to set command:FE 01 61 2B 00 4B / FE 01 61 2B 02 49 SOF Length Command Data FCS FE 01 61 2B Command state (1 byte) 4B 00 Data Description: 00 = Success 02 = Failure Xiamen Four-Faith Communication Technology Co.,Ltd. Add: J1-J3,3rdFloor,No.44,GuanRiRoad,SoftWare Park,XiaMen .China http://www.fourfaith.com Tel: +86 592-6300326 6300325 6300324 Page 85 of 99 Fax:+86 592-5912735