Download "user manual"

Transcript
FX3U/FX3UC Series PLC User's Manual - Positioning Control Edition
4 Before Programming
Built-in Positioning Function
A
Setting of Creep Speed (DSZR/ZRN Instruction)
Instruction
Setting range
Operand or
16-bit
32-bit
related
operation operation
device
(Hz)
D1
=Y000
D8345
D1
=Y001
D8355
D1
=Y002
D8365
D1
=Y003*2
D8375
ZRN instruction
4.2.5
S2
Instruction format
Apx.
(Hz)
10 to 32767
Initial value: 1000
DSZR
S1•
S2•
D1•
D2•
10 to 32767
ZRN
S1•
S2•
S3•
D•
*1.
If the maximum speed is set to less than 32767 Hz, note that this value (32767 Hz) should be changed
to the maximum speed.
*2.
Devices related to Y003 (pulse output destination) are valid only if two FX3U-2HSY-ADP adapters are
connected to the FX3U PLC.
Setting of Maximum Speed
Set the maximum speed to determine the upper limit value for the output pulse frequency and the zero return
speed.
Use the devices shown in the following table to determine the maximum speed for each pulse output
destination device.
Pulse output
destination device
Maximum
speed
Y000
D8344,D8343
Y001
D8354,D8353
Y002
D8364,D8363
*1
Y003
*1.
D8374,D8373
Setting range
Initial value
Transistor output of main
unit
High-speed output special
adapter
10 to 100,000 Hz:
If the value is set to 9 Hz or
100,000Hz
less, the maximum speed will
be automatically set to 10 Hz.
10 to 200,000 Hz:
If the value is set to 9 Hz or
less, the maximum speed will
be automatically set to 10 Hz.
Devices related to Y003 (pulse output destination) are valid only if two FX3U-2HSY-ADP adapters are
connected to the FX3U PLC.
Caution:
• To use the main unit (transistor output), set the output pulse frequency (absolute value) to 100,000 Hz or less.
If more than 100,000 Hz pulse is output from the transistor output of the main unit to perform operation, it may
cause PLC failure.
• Set the output pulse frequency so that the output pulse frequency value can be less than the maximum frequency
value of the servo amplifier (driver unit).
B - 35
Example
Connection
DSZR
instruction
B
Built-in
Positioning
Function
Use the related device or the operand of the instruction to set the creep speed. The creep speed setting
range is shown in the following table.
Be sure to set the creep speed so that the relation with the other speeds can be "bias speed ≤ creep speed ≤
32767 Hz*1".
→ For operation of DSZR instruction, refer to Section 6.2.
→ For operation of ZRN instruction, refer to Section 6.3.
Common Items
4.2.4
4.2 Setting of Various Items Regarding Speeds