Download "user manual"
Transcript
FX3U/FX3UC Series PLC User's Manual - Positioning Control Edition 4 Before Programming Built-in Positioning Function A Setting of Creep Speed (DSZR/ZRN Instruction) Instruction Setting range Operand or 16-bit 32-bit related operation operation device (Hz) D1 =Y000 D8345 D1 =Y001 D8355 D1 =Y002 D8365 D1 =Y003*2 D8375 ZRN instruction 4.2.5 S2 Instruction format Apx. (Hz) 10 to 32767 Initial value: 1000 DSZR S1• S2• D1• D2• 10 to 32767 ZRN S1• S2• S3• D• *1. If the maximum speed is set to less than 32767 Hz, note that this value (32767 Hz) should be changed to the maximum speed. *2. Devices related to Y003 (pulse output destination) are valid only if two FX3U-2HSY-ADP adapters are connected to the FX3U PLC. Setting of Maximum Speed Set the maximum speed to determine the upper limit value for the output pulse frequency and the zero return speed. Use the devices shown in the following table to determine the maximum speed for each pulse output destination device. Pulse output destination device Maximum speed Y000 D8344,D8343 Y001 D8354,D8353 Y002 D8364,D8363 *1 Y003 *1. D8374,D8373 Setting range Initial value Transistor output of main unit High-speed output special adapter 10 to 100,000 Hz: If the value is set to 9 Hz or 100,000Hz less, the maximum speed will be automatically set to 10 Hz. 10 to 200,000 Hz: If the value is set to 9 Hz or less, the maximum speed will be automatically set to 10 Hz. Devices related to Y003 (pulse output destination) are valid only if two FX3U-2HSY-ADP adapters are connected to the FX3U PLC. Caution: • To use the main unit (transistor output), set the output pulse frequency (absolute value) to 100,000 Hz or less. If more than 100,000 Hz pulse is output from the transistor output of the main unit to perform operation, it may cause PLC failure. • Set the output pulse frequency so that the output pulse frequency value can be less than the maximum frequency value of the servo amplifier (driver unit). B - 35 Example Connection DSZR instruction B Built-in Positioning Function Use the related device or the operand of the instruction to set the creep speed. The creep speed setting range is shown in the following table. Be sure to set the creep speed so that the relation with the other speeds can be "bias speed ≤ creep speed ≤ 32767 Hz*1". → For operation of DSZR instruction, refer to Section 6.2. → For operation of ZRN instruction, refer to Section 6.3. Common Items 4.2.4 4.2 Setting of Various Items Regarding Speeds