Implementation
Introduction
The implementation chapter describes all the steps necessary to initialize, to configure, to
program and start-up the system to achieve the application functions as listed below.
Function
Start up and functional description
1. Ensure all motor circuit breakers and Multi9 circuit breakers are in the ON position.
2. Ensure that the main switch is in the ON position.
3. Press the "ACKN E-STOP" blue illuminated pushbutton on the main cabinet door
to acknowledge the system is energized. The blue illuminated pushbutton will turn
OFF if the system is energized.
4. Ensure that all machine interlocks are engaged (i.e. the door guard switches)
5. Press the "ACKN DOOR-READY" blue illuminated pushbutton on the main cabinet
door to acknowledge the system is ready for operation. The blue illuminated
pushbutton will turn OFF if the system is ready for operation.
6. Use Magelis HMISTU655 to control/monitor the system.
a. The “BUS”, “ALARMS”, “SAFETY” screens can be used to monitor the
network, system status and alarm messages.
b. The “ATV312” screen can be used to control/monitor Altivar 312 variable
speed drives.
c. The “LXM32” screen can be used to control/monitor Lexium 32 servo
drives.