4.1.3 Installation and connection operating panel Both control panels can be mounted on a standard mounting box. For this, seperate the the mounting frame from the operating panel, screw the frame into the mounting box, attach the cable as shown below and click the operating panel back on the frame. Note that the panel must be mounted in an area between 10°C and 30°C with a maximum relative humidity of 80%. You have to connect the operating panels on the unit by means of a cable 4x0,5mm² with flexible conductors. Ventilair Group Nederland can supply the right (numbered) cable (article reference 0620166). Connect the numbers of the connection on the unit with the corresponding numbers on the operating panel. Ventilair Group Nederland can also supply a protection cap for the cable on the unit (article reference 0540131). Make sure the wires are not mixed up or short-circuiting, this can cause damage! Connection on the back side of the intelligent 3position switch At the 3-position switch connector only number 1 is shown. The three connections next to it are 2, 3 and 4. To the left of the connector is a jumper which has two possibilities: holiday speed (a) and off (b). We strongly recommend not to change the setting. Moving the jumper to position b means the unit has no holiday speed, in stead it will be switched off. Connection on top of the unit 4.1.4 1. 2. Connection on the back of the digital deluxe operating panel 3. 4. 5. 12 Connection of the air ducts In a heat recovery system, always use silencers and pipes of the right diameter to keep the air resistance and noise as low as possible. For advice on the correct pipe diameter, please contact Ventilair Group Nederland. Install the pipes as shown on the sticker on top of the unit, or look in section 6.3. Install the air exhaust pipe draining towards the unit because of possible condensation in the pipe. For the connections to the outside, always use isolated pipes to avoid condensation in the pipes. Place the inlet of fresh air preferably on the shady side of the house; this way you avoid extremely hot air supply in the summer. Note also that the inlet of fresh air is placed sufficiently far from a flue, according to local standards. Also, consider compound boundary rules. And make sure that no rain or animals can enter the pipes. Ventilair Group Nederland recommends to use a straight pipe of at least 40 cm, on the side of the supply air, before using a bend. This way, the supply fan performs optimally. For the home side Ventilair Group Nederland recommends you to apply rigid