Download User`s Manual Version 5.2
Transcript
Mediant 1000 3.3.2 Installing Mediant 1000 in a 19-inch Rack The Mediant 1000 can be installed in a standard 19-inch rack by implementing one of the following methods: Placing it on a pre-installed shelf in the rack (recommended method) Attaching it directly to the rack’s frame using the Mediant 1000 integral front mounting brackets and the user-adapted rear mounting brackets (not supplied). This method is required for racks that don't provide shelves. Rack Mount Safety Instructions (UL) When installing the chassis in a rack, be sure to implement the following Safety instructions recommended by Underwriters Laboratories: • Elevated Operating Ambient Temperature: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. • Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation on the equipment is not compromised. • Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. • Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. • Reliable Earthing: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips.) ¾ To mount the Mediant 1000 on a pre-installed shelf in the rack, take this step: Place the Mediant 1000 on a pre-installed shelf in the rack. It's recommended to attach the Mediant 1000 integral front mounting brackets to the rack's frame to prevent it from sliding off the shelf during cabling. Use standard 19-inch rack bolts (not provided) to fasten the front of the Mediant 1000 to the frame of the rack. SIP User's Manual 34 Document #: LTRT-83302
Related documents
Audiocodes Mediant 600
SIP User`s Manual
User`s Manual
User's Manual Version 5.0
AIRMATE-USB MANUAL-1.indd - D&R Broadcast Mixing Consoles
User`s Manual Version 5.0
Audiocodes Mediant 600 and 1000 SIP User Guide
Audiocodes MediaPack 114
Release Notes - NFS Professional Services
DMX - O`Boyle SRL
User`s Manual Version 5.0
User`s Manual