Download view catalog

Transcript
Order Date
Month/
Day/
Year/
Company
name
Name of the
person in charge
Monoblock Manifold F Type
Order No.
Specifications Confirmation Form
Equipment
name
●Fill in selections inside the thick-lined boxes.
Manifold model
Station 1
F
M
2 …… n
F
A B A B A B
Valve size
Valve units
10 : 10mm width 2∼20
15 : 15mm width
18 : 18mm width
stn.
F
Solenoid
Left side
Valve size
T Valve specification -
Note 1
- Note 2 -
Right side
- Note 3
Illustration shows the F10 series.
Voltage
DC24V
DC12V
AC100V
Valve output type
FJ : With different size fitting block (F10:φ4 and φ6, F15:φ6 andφ8, F18:φ8 and φ10)Note 2
FJ5 : With single size fitting block (F10:φ4, F15:φ6, F18:φ8)Note 2
FJ6 : With single size fitting block (F10:φ6, F15:φ8, F18:φ10)Note 2
FM : With female thread block (F10:M5×0.8, F15:Rc1/8, F18:Rc1/4)Note 2
Wiring specification
Blank : L type plug connector
Without connector
PN : S type plug connector
Without connector
PS : S type plug connector
Lead wire length 300mm
PL : L type plug connector
Lead wire length 300mm
PS3 : S type plug connector
Lead wire length 3000 mm
PL3 : L type plug connector
Lead wire length 3000 mm
Individual air supply and exhaust spacer Note 3
Blank : Without spacer
NPM : Individual air supply spacer (with M5 female thread for F10)
NP6 : Individual air supply spacer (with φ6 fitting for F15)
NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18)
NP0 : Individual air supply spacer (with φ10 fitting for F18)
NRM : Individual exhaust spacer (with M5 female thread for F10)
NR6 : Individual exhaust spacer (with φ6 fitting for F15)
NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18)
NR0 : Individual exhaust spacer (with φ10 fitting for F18)
CPS : Plus common pre-wiring connection
S type plug connector
Lead wire 300mm
CPL : Plus common pre-wiring connection
L type plug connector
Lead wire 300mm
CPS3 : Plus common pre-wiring connection
S type plug connector
Lead wire 3000 mm
CPL3 : Plus common pre-wiring connection
L type plug connector
Lead wire 3000 mm
※For the valve and block-off plate mounted at each station, enter ○ for each designated station below.
Mounting valve, block-off plate
Station
F□T0
2-position, single solenoid only
F□T1
2-position, single solenoid specification
F□T2
2-position, double solenoid specification
F□T3
3-position, all port block
F□T4
3-position, ABR connection
F□T5
3-position, PAB connection
F□BP
Block-off plate
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20 Quantity
Manual override (-R) Manual lever override
FJ With different size fitting block
Valve
output
type Note 2
FJ5 With single size fitting block
FJ6 With single size fitting block
FM With female thread block
NPM Individual air supply spacer (with M5 female thread for F10)
NP6
Individual air supply spacer (with φ6 fitting for F15)
NP8
Individual air supply spacer (with φ8 fitting for F15 and F18)
NP0
Individual air supply spacer (with φ10 fitting for F18)
NRM Individual exhaust spacer (with M5 female thread for F10)
NR6 Individual exhaust spacer (with φ6 fitting for F15)
NR8 Individual exhaust spacer (with φ8 fitting for F15 and F18)
NR0 Individual exhaust spacer (with φ10 fitting for F18)
Notes: 1. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table.
2. Select from FJ, FJ5, FJ6, FM in the valve type column of the above table, and enter ○ for each station.
3. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table.
Quantity
Delivery
set
623
SOLENOID VALVES F SERIES
Mounting valve models
Manual override
Blank : Manual override
R : Manual lever
overrideNote 1
(made to order)