Download view catalog
Transcript
Presenting our CAD drawing data catalog VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX Characteristics Product Range Table of Cylinder Operating Speed Operating Principle and Symbol Handling Instructions and Precautions Disassembly Diagram and Unit Adding Procedure Product Configurations for Serial Transmission Compatible Manifold Specifications of Serial Transmission Compatible Manifold Precautions for Use Due to Partial Specification Change Order Code Solenoid Valves F10 Series Specifications Dimensions Solenoid Valves F15 Series Specifications Dimensions Solenoid Valves F18 Series Specifications Dimensions F Series Specifications Confirmation Form 506 508 510 511 512 518 525 526 528 531 567 568 572 585 586 590 603 604 608 619 505 New Valve pursuing user friendlier operability and improving performance NEW Basic VALVE F SERIES SOLENOID VALVES 1. alve ange v Can ch on-site! n o functi Single/double dual-use valves The F Series 2-position valves’ function can be switched back and forth between single solenoid valve and double solenoid valve by using the manual override. This enables using models can be intensified against diversified application requirement. Two types in one! Note: Excluding T0 (T-Zero) type Solenoid Valves F10 Series Solenoid Valves F15 Series Solenoid Valves F18 Series ●Valve width: 10mm ●Effective area: 5mm2 ●Applicable cylinder bore sizes: φ20∼φ50 506 ●Valve width: 15mm ●Effective area: 10mm2 ●Applicable cylinder bore sizes: φ40∼φ80 ●Valve width: 18mm ●Effective area: 18mm2 ●Applicable cylinder bore sizes: φ50∼φ100 2. Uses dual-use fittings for different tube sizes. Allows tubes of different outer diameter to be connect- ed.Series F10 F15 Applicable tube sizes φ4, φ6 φ6, φ8 φ8, φ10 F18 Note: Single size fittings can also be selected. 3. More compact, and high flow rate Flow rate up by 2~3.3 times with the same valve width (compared with Koganei product). Solenoid valves 110 series 15 Solenoid valves F15 series Effective area Effective area 4.0mm 10mm 2 A B 2 15 4. Single solenoid valve T0 (T-zero) type added ●A valve for single solenoid only has been added to the F series solenoid valve range inheriting the same design concept for easier selection. Moreover, it can be combined mounting with earlier manifolds, offering good maintenance. 5. Offering user friendlier operability ●Replacing output blocks make it possible to change between base piping and direct piping. ●(Except monoblock manifold F type and PC board manifold F type) ●External pilot specification also can be selected. External pilot (positive pressure) specification allows to operate from 0 MPa as main pressure. Vacuum specification can also be selected. P2 port [] (Base piping) (Direct piping) ●Female thread block and fitting blocks can be selected. For the fitting block, a fitting for single size only has been added to the previous dual-use fitting for different size tube, offering easier selection and usage. Single size fitting block-FJ6 Single size fitting block-FJ5 Dual-use different size fitting block ● Both locking and nonlocking type manual override is standard equipment. A manual lever override can also be Manual lever selected. override (made to order) Female thread block Manual override ●Full range of wiring specifications. ●The PC board manifold has been added to the monoblock type. A flat cable connector, D sub connector and terminal block are provided for the split manifold plug-in type. In addition, serial transmission compatible manifolds to 12 types of systems are also available. ●Individual air supply and exhaust offered. ●Specially designed air supply or exhaust spacers installed between the manifold and valve allow individual air supply or exhaust. 6. Achieves power consumption of 0.9W (Current 38mA, DC24V) ※Power consumption per one valve (for DC24V specification) 507 SOLENOID VALVES F SERIES ●Shared connectors (Single valve unit can also be used as plug-in type). ]\ F Series Product Range Single Valve Unit Valves can be used as a single unit by attaching an input port block. Mounting brackets are also provided. Output port specifications With sub-base Series Female thread Rc 1/8 F10 ● F15 ● Rc 1/4 F18 With fitting block With female thread block For single valve unit or manifold use With female thread block With different size fitting block M5 Rc 1/8 Rc 1/4 φ4,φ6 φ6,φ8 φ8,φ10 φ6 ● ● ● ● ● ● ● With single size fitting block φ4 With A type sub-base ● ● ● ■With mounting bracket φ8 φ10 ● ● ● Order code p.532,533 F10series p.572 dimensions F15series p.590 dimensions F18series p.608 dimensions Monoblock Manifold A Type This base piping type manifold offers both maintenance and cost performance. Replacing the output block enables to use as a direct piping type manifold. Using a plug connector with common terminal pre-wiring greatly reduces wiring work. With fitting block With female thread block ■Common terminal prewiring plug connector Order code p.534,535 F10series p.575 dimensions F15series p.593 dimensions F18series p.611 dimensions Monoblock Manifold F Type Manifold for direct piping type offers excellent cost performance. Using a plug connector with common terminal pre-wiring greatly reduces wiring work. (Base Piping Type) With fitting block (Direct Piping Type) With female thread block ■Common terminal prewiring plug connector Order code p.536,537 F10series p.576 dimensions F15series p.594 dimensions F18series p.612 dimensions 508 PC Board Manifold A MIL type 20-pin flat cable connector is mounted on the monoblock manifold, to achieve both wiring savings and cost performance. Combined use of the Koganei PC wiring system and wiring specification -F201 allows for more effective wiring savings. Note: Not available for F18 series. A type (Base piping type) F type (Direct piping type) Order code p.538∼541 F10series p.577 dimensions F15series p.595 dimensions Split Manifold Non-Plug-in Type Enables easy addition or removal of manifold blocks. This system offers more flexibility in conforming to changes in specifications. Manifold port with fitting block Valve port with fitting block Manifold port with female thread block Valve port with female thread block Order code p.542∼545 F10series p.578 dimensions F15series p.596 dimensions F18series p.613 dimensions Split Manifold Plug-in Type Manifold port with fitting block Valve port with fitting block Manifold port with female thread block Valve port with female thread block Order code p.546∼549 F10series p.579 dimensions F15series p.597 dimensions F18series p.614 dimensions Wiring ■Flat cable connector Additional Parts ■D sub connector ■Terminal block ■Muffler Dimensions F10 : p. 583 F15 : p. 601 F18 : p. 618 Serial Transmission Compatible Manifold ●For Mitsubishi Electric MELSECNET/MINI-S3 ●For Omron SYSBUS Wire System ●For Mitsubishi Electric MELSEC I/O Link ●For Omron B7A Link Terminal ●For Mitsubishi Electric CC-Link ●For Omron CompoBus/D ●For UNI-WIRE® System ●For Omron CompoBus/S ●For KOYO Electronics Industries SA Bus ●For Fuji Electric T Link Mini ●For Sunx S-Link ●For Keyence KZ-R Order code p.550∼556 F10series p.582 dimensions F15series p.600 dimensions F18series p.617 dimensions ※For details, see p. 525∼527. 509 SOLENOID VALVES F SERIES Manifold conforms to reduced wiring work. Adding on wiring allows adding manifold units. Combined use of the Koganei PC wiring system and wiring specification -F201 offers more effective wiring savings. Table of Cylinder Operating Speed 1. Cylinder mounting direction : Vertical Cylinder series/Conditions/Cylinder bore size mm Slim Cylinder Series NEW Pen Cylinder Series Cylinder Series speed mm/s Pressure : 0.5MPa Load ratio : 50% Cylinder stroke : 150mm Piping (outer diameter × inner diameter × length) : φ6×φ4×1000mm 10 150 F10 series 300 Effective area 450 5mm2 600 16 20 F15 series 300 Effective area 450 10mm2 600 F18 series 300 Effective area 450 18mm2 600 32 40 50 ※ 63 80 100 ★ ★ ※ ※ ★ ★ ★ ★ ★ 750 150 25 Pressure : 0.5MPa Load ratio : 50% Cylinder stroke : 150mm Piping (outer diameter × inner diameter × length) : φ10×φ7.5×1000mm ※ 750 150 NEW DYNA Cylinder Series Pressure : 0.5MPa Load ratio: 50% Cylinder stroke : 150mm Piping (outer diameter × inner diameter × length) : φ6×φ4×1000mm ※ ※ ★ ★ 750 ★ : Use each cylinder type within their operating speed range. ※ : Cylinder speed is limited by the connection port orifice size. Remark : For load ratio of other than 50%, see the "Cylinder Operating Speed" in the specifications for each valve. 2. Cylinder mounting direction : Horizontal (Roller bearing: Friction coefficient μ=0.1) Cylinder series/Conditions/Cylinder bore size mm Slim Cylinder Series NEW Pen Cylinder Series Cylinder Series speed mm/s Pressure : 0.5MPa Load ratio : 50% Cylinder stroke : 150mm Piping (outer diameter × inner diameter × length) : φ6×φ4×1000mm 10 16 NEW DYNA Cylinder Series Pressure : 0.5MPa Load ratio: 50% Cylinder stroke : 150mm Piping (outer diameter × inner diameter × length) : φ6×φ4×1000mm 20 25 32 40 Pressure : 0.5MPa Load ratio : 50% Cylinder stroke : 150mm Piping (outer diameter × inner diameter × length) : φ10×φ7.5×1000mm 50 63 80 150 F10 series 300 Effective area 450 5mm2 600 ※ ※ ★ ★ 750 ★ 150 F15 series 300 Effective area 450 10mm2 600 ※ ※ ★ 750 150 ※ ※ F18 series 300 Effective area 450 18mm2 600 750 ★ ★ ★ ★ ★ ★ : Use each cylinder type within their operating speed range. ※ : Cylinder speed is limited by the connection port orifice size. Remark : For load ratio of other than 50%, see the "Cylinder Operating Speed" in the specifications for each valve. 510 ★ ★ ★ ★ ※ ★ ★ ★ 100 Operating Principle and Symbol 5-port, 2-position 14 (SA) When set as a single solenoid ( 4 A) ( 2 B) 14 (SA) When set as a double solenoid ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) F□T1□-A1 (De-energized) P2 P2 Note 1 Solenoid SolenoidA〔14(SA)〕 Solenoid cover ( 5 R1) ( 1 P) ( 3 R2) Note 1 12 (SB) B〔12(SB)〕Note 3 Column Molded solenoid Plunger Plunger spring Flapper Piston Major Parts and Materials Lip seal Parts PR P2 External pilot Note 1 Sub-base 1(P) Plunger 2(B) Column End cover 3(R2) Stem Manifold Valve body Synthetic rubber Aluminum alloy (anodized) Magnetic stainless Plastic Monoblock Aluminum alloy (anodized) Split type Plastic Block-off plate Steel (nickel plated) Notes: 1. For external pilot type 2. Not available in external pilot type 3. Not available with T0 type ※Illustration shows when setting as ※the single solenoid. Aluminum alloy Flapper Valve 4(A) End cover Stem Lip seal 5(R1) Manual override Note 3 Aluminum die-cast Seal Synthetic rubber 5-port, 3-position 〔Both 14 (SA) and 12 (SB) are de-energized〕 All port block ABR connection 14 (SA) F□T3□-A1 F□T4□-A1 ( 4 A) ( 2 B) Note 1 P2 P2 12 (SB) P2 Note 1 Note 2 5(R1) ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) Note 1 P2 12 (SB) PR Note 1 P2 PR Note 2 14 (SA) F□T5□-A1 ( 4 A) ( 2 B) ( 5 R1) ( 1 P) ( 3 R2) PAB connection 14 (SA) 5(R1) ( 5 R1) ( 1 P) ( 3 R2) Note 1 12 (SB) PR P2 Note 1 Note 2 5(R1) 4(A) 4(A) 4(A) 1(P) 1(P) 1(P) 2(B) 2(B) 2(B) 3(R2) 3(R2) 3(R2) Notes: 1. For external pilot type 2. Not available in external pilot type 511 SOLENOID VALVES F SERIES Internal pilot Note 2 Materials Body Body Manual override Pilot valve body Handling Instructions and Precautions Solenoid Single and double solenoid switching procedure Wiring instructions (When using as a single unit, non-plug-in type manifold) By switching the manual override, model F□T1(2-position valve)can be used as either a single solenoid valve or a double solenoid valve (not possible with 3-position valve). Note that the F □T1 is set to single solenoid specification at time of delivery. Switching from a single solenoid valve to a double solenoid valve 1.As shown in Fig.1, insert the Convex section Pin Claw Caution: As shown in Fig.1, be sure to insert a small screwdriver from the side of the valve cover. The cover claw may be damaged when the cover is removed from the direction of the valve stem. Never remove the cover for any reason other than the valve function switching. Lever Housing Convex section ※Illustration shows the F10 series. Plug connector Pin Contact 〔Figure 1〕 2. As shown in Fig. 2, use a Turn the manual override in a counterclockwise direction for setting double solenoid. B side manual override Single solenoid state Double solenoid state The manual override is protruding. Caution: When using as a double solenoid valve, do not attach the cover that was removed in Fig. 1. 〔Figure 2〕 Switching from a double solenoid valve to a single solenoid valve As shown in Fig. 3, use a small screwdriver, etc., to push lightly against the manual override, and then turn it by 90 degree in a clockwise direction, so that the manual override slit is vertical, and then attach the cover. Caution: The cover has directionality (F15 and F18 series only). When attaching, always align the detent on the back of the cover with the manual override button’s slit, as shown in Fig.4. Use fingers to insert the connector into the pin, push in until the lever claw catches on the convex section on the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the convex section on the housing, and pull out. Housing Cover tip (−) of a small screwdriver into the gap between the valve and the cover, and peel it off and remove the cover. small screwdriver, etc., to turn the manual override on the B side by 90 degree in a counterclockwise direction, so that the manual override slit is horizontal, as shown on the right side of the figure, then the unit can now be used as a double solenoid valve. When using as a double solenoid valve, the override is used as the manual override for the B side. 1.Attaching and removing plug connector Push lightly, then turn the manual overrride in a clockwise direction for setting single solenoid. Lead wire (White) Cautions: 1.When removing the connector, confirm that the lever claw is positively disengaged from the convex section before pulling out. The housing may be damaged if it is pulled out while engaging with the convex section. 2.The plug connector lead wires for model F□T1 (2-position valve) are set to single solenoid specification at time of delivery. (For types with plug connector) 2.When switching from a single solenoid to a double solenoid specification for use, disconnect the plug connector from the valve, check the hook directions on the lead wire (white) with contacts, and then insert the lead wire into the plug connector's B side□ hole (see illustration above). Use the same procedure to switch the manifold type single solenoid to double solenoid specification. 3.When using the plug-in type manifold, be aware that even if the valve has been switched to a double solenoid, no power will be supplied to the B side solenoid unless the valve base wiring are set to the double wiring. 2.Attaching and removing plug connector and contact ●Attaching Insert the contact with a lead wire into a plug connector □ hole until the contact hook catches and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. (See below) ●Removing To remove, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the side of the plug connector to push up on the hook of the contact, and then pull out the lead wire. When reusing the contacts, restore the hook back so that they spread outward. Plug connector Manual override Hook Contact Double solenoid state Single solenoid state The manual override is protruding. Note about wiring for above switching 〔Figure 3〕 Lead wire 3.Common terminal and short bar A short bar is attached to the plug connector to ensure that the solenoid A and B wiring are plus common. Do not remove the short bar. Cover (Back face) See the "Wiring instructions" at right. Detent End cover Manual overrride 〔Figure 4〕 512 Indication of polarity(DC) Short bar Contact(without lead wire) 4.Crimping of connecting lead wire and contact Internal circuit To crimp lead wires into contacts, strip off 4mm of the insulation from the end of the lead wire, insert into the contact, and crimp it. Be sure to avoid catching the insulation on the expose wire crimping section. Voltage specification Internal circuit (Inside of the connector) Insulation crimp tab Expose wire 4mm Expose wire crimping section (Color of lead wire: Black) A (Red) Lead wire Applicable wire AWG#24∼#30 Contact Hook Insulation (Maximum outer diameter:φ1.5) 14 (SA) DC24V DC12V (Color of lead wire: Red)+COM 12 (SB) (Green) Cautions: 1. Do not pull hard on the lead wire. 2. Always use the dedicated tool for crimping of connecting lead wire and contact. Contact: Model 706312-2MK Manufactured by Sumiko Tech, Inc. Crimping tool: Model F1 (For 706312-2MK) Manufactured by Sumiko Tech, Inc. (Color of lead wire: White) B (Inside of the connector) (Color of lead wire: Black) (Red) A 14 (SA) 5.Common connector assembly for manifold Using common connector assembly for the solenoid valve for manifold provides common wiring for all solenoid valves and greatly reduces wiring work. AC100V (Color of lead wire: Red) COM (Color of lead wire: White) Single solenoid valve B (Green) 12 (SB) Double solenoid valve Common wire(+) Common wire(+) Common wire(+) ) C type BA BA A ― A( 〔Figure 5〕 ―) ( Cautions: 1. Do not apply megger between the pins. 2. For switching wiring between a single solenoid and a double solenoid, see the "Wiring instructions" item on p. 512. 3. Common wiring set for double solenoid in DC specification is plus common specification. 4. Leakage current inside the circuit could result in failure of the solenoid valve to return to the rest position or in other erratic operation. Always use at less than the allowable leakage current shown in the solenoid specifications on p. 568, 586, and 604. If circuit conditions, etc., cause the leakage current to exceed the maximum allowable leakage current, consult us. 5. For the double solenoid specification, avoid energizing both solenoids simultaneously. 6.Common connector assembly (plus common specification) If wanting to add units after mounting to the connector assembly for manifold, order the common connector assembly shown below. A type Model:FZ-PA□※ Red Common wire (+) Black A side (−) White B side (−) (Insert when using as a double solenoid) B type Model:FZ-PB□※ C type Model:FZ-PC□※ Red Common wire (+) Black A side (−) White B side (−) (Insert when using as a double solenoid) Red Black White Red Note:FZ0-P□□ has no white wires. Common wire (+) A side (−) B side (−) (Insert when using as a double solenoid) Common wire (+) ※: Lead wire length Blank: 300mm 3: 3000mm The common connector types are determined by looking from the lead wire side, the right end one is A type, the left end one is C type, and all others are B type. (see Fig. 5) 7.Cabtire cable φ4.2 CC1.5:1500mm CC3:3000mm (32.2) Connector PC board manifold When connecting a power line to the power supply terminal on the PC board manifold, pay attention to the following points to connect. Power supply terminal Terminal screw tightening torque: 0.4N・m {0.04kgf・m} Stripped wire length: 7mm Connecting wire size: 0.13∼2.5mm2 AWG: No.26...14 If planning to use pressing terminals, use bar terminals. Recommended pressing terminals (bar terminals): Manufactured by Nichifu, Inc. Model BT1.25-9-1 (for 0.25∼1.65mm2) Wiring of terminal block Be aware of the terminal screw tightening torques. Overtightening beyond the tightening torque could result in breakage. Terminal screw tightening torque: Max. 49.0N・cm {5.0kgf・cm}. Cap Caution: Be aware that these are not dust-proof and drip-proof specifications. 513 SOLENOID VALVES F SERIES B type A type Valve function 3-port valves Manual override Manual override (both locking and non-locking type) To lock, use a small screwdriver to push down on the manual override all the way down and turn it clockwise 90 degrees. When locked, turning the manual override 90 degrees in a counterclockwise direction, releases a spring on the manual override, returns it to the original position and releases the lock. To operate the unit in the same way as the nonlocking type, leave the manual override unturned. Cautions: 1. The F series are pilot type solenoid valves. As a result, the manual override cannot switch the main valve without supplying air from the P(P2) port. 2. Always release the lock on the manual override before commencing normal operation. For details (excluding the 3-position valve), see the "Single and double solenoid switching procedure" on p. 512. 3. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. 4. Take care to avoid excessive turning of the manual override, which could damage it. 5. If operating the solenoid valve's manual override for maintenance, etc., always confirm that the solenoid valve's override button has been restored to its original state, and that the main valve is in the necessary switching position before restarting operations. When using the 5-port valve as a 3-port valve In the F10, F15, and F18 series, plug one of the output ports (A or B) enabling to use as a normally closed (NC) or normally open (NO) 3-port valve. In this case, leave the exhaust ports (R1 and R2) in the open status. This can also be applied to a double solenoid-type 3-port valve. Plug position Plug the B port Plug the A port Switching type Normally closed(NC) Normally open(NO) For single solenoid setting When using models F □T1 or F □T2 (2-position valve) as double solenoid valves, be aware that energizing the A side solenoid or pushing the manual override on the A side while in a locked state, while energizing the solenoid on the B side, or while pushing the B side manual override, cause the valve to switch over. (At this time, the valve will operate as the same state as for the single solenoid valve.) For double solenoid setting Precautions for use of the double solenoid To lock, use fingers to push down on the lever all the way down and turn it clockwise 90 degrees. When locked, turning the manual lever override 90 degrees in a counterclockwise direction, releases a spring on the manual override, returns it to the original position, and releases the lock. To operate the unit in the same way as the non-locking type, leaving the lever unturned. Caution: Model F□T1 (2-position valve) has a manual lever override on the A side and a manual override (with cover) on the B side. Model F□T2 has a manual lever override on the A side only, and a manual override on the B side. The 3-position valve has manual lever override on both the A and B sides. ( 4 A) (Plug)( 2 B) 14 (SA) (Plug)( 4 A) ( 5 R1) ( 1 P) ( 3 R2) ( 2 B) 14 (SA) ( 4 A) (Plug)( 2 B) ( 5 R1) ( 1 P) ( 3 R2) 14 (SA) ( 5 R1) ( 1 P) ( 3 R2) ( 4 A) (Plug) ( 2 B) 12 (SB) ( 5 R1) ( 1 P) ( 3 R2) 12 (SB) Manifold Manual lever override (both locking and non-locking type) (made to order) 14 (SA) Attaching and removing valves To remove the valve body from the sub-base or manifold, loosen the valve mounting screws (2 places), and lift up in the direction of the arrow (see diagram at right). For mounting, conduct the same procedure in reverse. The recommended tightening torques for the valve mounting screws are as shown below. ※Illustration shows the F10 series. (split manifold) Series Manual lever override N・cm{kgf・cm} Recommended tightening torque F10 17.6 {1.8} F15 49.0 {5.0} F18 49.0 {5.0} TURN Sub-plate (service part) A side manual override PUSH B side manual override A sub-plate is provided as a service part required for mounting new type valves on the earlier type of split manifold plug-in type, and the earlier type of serial transmission compatible manifold. For details, see "Precautions for Use of Partial Specification Changes (for Deliveries after January 30, 1997)"(p. 528∼529). Sub-plate F (sub-plate, gasket, O ring, 2 mounting screws) Z-S Valve size 10:10mm width 15:15mm width 18:18mm width ※Illustration shows the F10 series. 514 Fitting Split Piping In the split manifold, inserting splits to the P and R ports between each of the stations isolate the air path between stations equipped with splits and stations with smaller station numbers. Note, however, that a piping block must be placed on both ends. ●Splits for the P port (Mode : F□Z-SP) Can supply two different pressures. ●Splits for the R port (Model : F□Z-SR) Can isolate exhaust air . (prevents exhaust interference) ●Splits for the P and R ports (Model : F□Z-SA) Can supply two different pressures, and can isolate exhaust air. (prevents exhaust interference) 1. Procedure for replacing the base piping type and the direct piping type Base piping and direct piping re-combinations can be done by replacing the plate with a fitting block or a female thread block. (see Fig. 6). A port B port Fitting block Plate B port A port ※□ denotes valve size. Plate 〔Figure 6〕 〔F10, F15 series〕 ※Illustration shows the F10 series. SP: Split for the P port Cautions: 1. Firmly tighten the screws after completing a re-combination. 2. Conduct piping carefully in regards to the positions of each connection port (see Figs. 7, 8). 3. Be careful about losing the gaskets while conducting plate replacement. ● Direct piping type For F10, F15 series For F18 series A B A B A B A B A B A B P port A port B port A B A B A B A B R port A port Note P port B port R port Note SR: Split for the R port 〔Figure 7〕 Note: Be aware that the positions of the P and R ports are reversed from the positions in the F10 and F15 series. 〔F18 series〕 ● Base piping type Port positions for F10, F15, F18 series are as shown in Fig. 8. P port B port A port R port 〔Figure 8〕 SP: Split for the P port ※Illustration shows the F10 series. 2. Attaching fittings to female thread blocks SR: Split for the R port Caution: Mounting splits requires the disassembly and re-assembly of manifolds. See the disassembly diagram, unit adding procedure, and cautions found on p. 518∼523. Note, however, that since the F18 series serial transmission compatible manifold cannot be disassembled, splits cannot be mounted later. When attaching fittings to female thread blocks, fasten with the tightening torques shown below or less. Screw size Tightening torque N・cm {kgf・cm} Rc 1/8 686 {70} Rc 1/4 882 {90} ※For M5, attach at the torques recommended for the fittings. 3. Attaching fittings to piping blocks〔F18Z(G)-PM(P)〕 Precautions for using manifold Observe the following precautions when using the split type and serial transmission compatible manifold. (Except monoblock manifold and PC board manifold) To attach fittings to the female thread type piping block of the F18 series, remove the piping block section (the triangular-shaped block section), use a spanner to the metallic sections of both the P and R ports to fix them in place, and then screw in the fittings.The tightening torque for the mountings (two M3 screws) of the piping block section after the fittings have been attached should be 49.0 N・cm {5.0kgf・cm}. ●When using the direct piping type Avoid valve use at an operating frequency exceeding 2Hz, as such use can result in heat-related breakdowns. ●When using the base piping type When plugs have been attached either or both on the A and B ports, avoid valve using at an operating frequency exceeding 2Hz, as such use can result in heat-related breakdowns. 515 SOLENOID VALVES F SERIES ※Illustration shows the F10 series. Mounting screw Precautions for use of individual air supply and exhaust spacers Exhaust valve Gasket By mounting an independent air supply or exhaust spacer on the manifold, air supply or exhaust can be operated individually on the unit. Note that when spacers are used, the effective area is reduced by about 30%. If mounting additional spacers to an existing unit, observe the following items. Individual air supply and exhaust spacer ●Spacer mounting method (F10 series) q Loosen the valve mounting screws for the individual air supply or exhaust spacer, and remove the valve. w Install the gaskets and exhaust valve provided with the individual air supply or exhaust spacer, use the mounting screws provided to fix the valve on the manifold. (see Fig. 9) Remark: When attaching fittings to the F10 spacer, use the recommended fittings shown below. Remark: TSH4-M5M, TSH4-M5, TSH6-M5M, TS4-M50, TS4-M5M 〔Figure 9〕 Mounting screw Cover Color: Light blue F10 series (Illustration shows the split manifold plug-in type) Gasket ●Spacer mounting method (F 15, 18 series) q Loosen the valve mounting screws for the individual air supply or exhaust spacer, and remove the valve. w Open the cover of the manifold, and pull out the plug-in connector in the forward direction. (For the plug-in type) (see Fig. 10) e Insert the plug-in connector firmly into the connector attaching section of the individual air supply or exhaust spacer, and then close the cover, while watching to ensure that lead wires are not caught with the cover. (For the plug-in type) (see Fig. 11) r Attach the gasket and exhaust valve provided with the individual air supply or exhaust spacer, and use the mounting screws provided to mount the valve on the manifold. Cautions: 1. Locations where the spacers are mounted make the valve height higher by the height of the spacer. (See the dimensions below) 2. The F series split manifold plug-in type, and the serial transmission compatible manifold, have undergone partial specification changes, with the result that earlier and new types exist. A change in the shape of the connector receptacle means that it cannot be mounted on the earlier type manifold. Use the color of the cover to identify the new or earlier types (see Figs. 9 and 10). Type Item Color of cover Earlier type of manifold Ivory Exhaust valve Plug-in connector Plug-in connector Figure 11 〔Figure 10〕 Cover Color: Light blue F15,18 series (Illustration shows the split manifold plug-in type) New type of manifold Light blue ●Muffler for individual exhaust spacer Muffler for individual exhaust spacer Muffler for the independent exhaust spacer is provided. For outer dimensions, see p. 583, 601, and 618. Individual exhaust spacer ●Dimensions F10Z-N□ □ (For F10 series) Mass 7g F10Z-P□ □ (For F10 series) Mass 9g M5×0.8 58.5 95.3 10 10 M5×0.8 9 9 Valve side Manifold side F15Z-N□ □ (For F15 series) Mass 26g F15Z-P□ □ (For F15 series) Mass 29g 9.4(φ6, φ8) Fitting(φ6, φ8) 13 16 13 16 Fitting(φ6, φ8) F18Z-N□ □ (For F18 series) Mass 41g F18Z-P□ □ (For F18 series) Mass 44g 9.4(φ8) 17.5(φ10) 18.8 103.5 18.8 9.4(φ8) Fitting(φ8, φ10) 17.5(φ10) 13 18 13 18 Fitting(φ8, φ10) 516 129.5 15.8 90.5 15.8 9.4(φ6, φ8) Individual air supply and exhaust spacer 142.5 Dual-use different size fitting (With different size fitting block) The F series different size fitting blocks use dual-use fittings for different tube sizes, which can connect to tubes of two different outer diameter. (Excluding the P and R ports of the F18 Series) ●Attaching and removing tubes For tube connection, insert an appropriate size tube as far as contacting the tube stopper, and lightly pull on it to check the connection. For tube removal, push the tube against the tube stopper, then for large tube sizes, push on the release ring and at the same time pull the tube out. For small tube sizes, push on the outer ring and at the same time pull the tube out. (See Fig. 12) Release ring Tube stopper Release ring Outer ring Tube stopper 〔Figure 12〕 Large tube size Small tube size SOLENOID VALVES F SERIES Cautions: 1. Use tubes with an outer diameter tolerance within ±0.1mm of the nominal diameter, and a degree of out-of-ellipticity (difference between long diameter and short diameter) is 0.2mm or less. 2. Only use tubes without scratch is on the outer surface. If scratch is produced during repeated use, cut off the scratched section. 3. Do not bend the tube sharply near the fittings. The minimum bending radius for nylon tubes is as shown in the table below. 4. When attaching or removing tubes, always stop air supply. In addition, always confirm that air has been completely exhausted from the manifold. mm Tube size Minimum bend radius φ4 20 φ6 30 φ8 50 φ10 80 517 F10, 15 Series Disassembly Diagram of Split Manifold Non-Plug-in Type Figure 1 Fixing screw End block Disassembly example: For F10 series Piping block assembly Release lever Note: The F series has the same basic construction. Valve base assembly End block Manifold Unit Adding Procedure (F10 and F15 Series Non-Plug-in Type) ■Adding valve base unit Use the valve base assembly to add units. q Loosen the fixing screw on the end block until the end block can slide (see Fig. 1). Figure 2 First let the hook catch on this side, and then press down on the base to fit it into the DIN rail. Note: For the 15 series, loosen the fixing screws on both the left and right end blocks (three screws each). w Press the release lever on the valve base assembly where the new unit is to be added, and disconnect the link between the bases. e Mount the valve base assembly to be added on the DIN rail shown in Fig. 2. r Return the release lever of the valve base assembly disassembled in Step w to its original position, as shown in Fig. 3. In addition, set the release lever for the valve assembly being added to the same position, then press the bases together until they connect and click into place. t Press the bases together from both sides to ensure that there is no gap between them, and then tighten the end block fixing screws, and mount the units in place on the DIN rail (see Fig. 5). Tightening torque: 128N・cm {13kgf・cm} Notes: 1. Always follow the steps shown in Fig. 4 when tightening the end block fixed screws for the F15 series. 2. Confirm that the DIN rail mounting hooks are securely attached to the DIN rail. (see Fig. 5). 【Caution】 ●Always cut off the power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. ●Be careful not to be caught or lose gaskets. ●Before supplying air to the manifold, always confirm that the bases are connected, the end block fixing screws are tightened, etc. Supplying air when either of the end blocks are not securely fixed to the DIN rail could result in air leaks or in separated manifold bases. ●When there are large number of valves simultaneously supplying air to the secondary side, or when there is a large number of valve units, we recommend using two sources of air supply and exhaust (on each side). Note that adding units of the piping block assembly is conducted in the same way as adding units of the valve base assembly. Figure 3 Figure 4 ●Tightening order of screws(for F15 series only) A B A B A B 3 1 4 Pressing down lightly on the release lever will return it to its forward position. Figure 5 ●Fixing the end block in place Tighten the screw with the L-shaped hook pushed in. 5 2 6 Always tighten the middle fixing screw of each end block first. Tightening torque: 128N・cm {13kgf・cm} ●Removing the end block from the DIN rail w DIN rail Use hooks on both sides to fix the DIN rail in place. q For mounting, follow in reverse the steps taken for removal. Caution: The new end block for the F10 series does not include an L-shaped hook. To remove the end block from the DIN rail, loosen the end block fixing screws, and lift it off. (The switch to the new type will commence in October 2000) 518 F18 Series Disassembly Diagram of Split Manifold Non-Plug-in Type Figure 1 Connecting bolt End block Piping block assembly Valve base assembly End block Manifold Unit Adding Procedure (F18 Series Non-Plug-in Type) ■Adding valve base unit Use the valve base assembly and unit-adding connecting rod to add units. q Remove the connecting bolts on the end block and separate the end block from the manifold (see Fig. 1). w Install the connecting rods to be added, open up spaces where the units are being added, fit gaskets into the valve base assemblies being added, and place the units on top of the connecting rods. At this time, securely mount so that no space is left between the added valve base assemblies and the upper surface of the connecting rods. e Fit gaskets into the end blocks removed in Step q, and retighten the connecting bolts. At this time, use a hexagonal bar wrench to hold the connecting bolts on the opposite side in place so as to prevent the bolts from slipping while tightening them into place. Tightening torque: 147N・cm {15kgf・cm} 【Caution】 ●Always cut off power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. ●Be careful not to be caught or lose gaskets. ●Before supplying air to the manifold, always confirm that the bases are securely connected, the end block connecting bolts on both sides are tightened, etc. Supplying air when either of the end blocks is not securely fixed in place could result in air leaks or in separated manifold bases. ●When there are large number of valves simultaneously supplying air to the secondary side, or when there is a large number of valve units, we recommend to use two sources of air supply and exhaust (on each side). Note that adding units of the piping block assembly is conducted in the same way as adding units of the valve base assembly. 519 SOLENOID VALVES F SERIES Connecting rod F10, 15 Series Disassembly Diagram of Split Manifold Plug-in Type Fixing screw Figure 1 End block Disassembly example: For F10 series (using flat cable connector) Additional side Piping block assembly Additional position Release lever Cover Valve base assembly Note: The F series has the same basic configuration. Wiring block assembly End block Manifold Unit Adding Procedure (F10 and F15 Series Plug-in Type) ■Adding valve base unit Figure 2 Use the valve base assembly to add units. q Loosen the fixing screw on the end block until the end block can slide (see Fig. 1). First let the hook catch on this side, and then press down on the base to fit it into the DIN rail. Note: For the F15 series, loosen the fixing screws on both the left and right end blocks (three screws each). w Add units on the side shown in Fig. 1 (with the solenoid on top and the right). To split up at additional unit location, push the piping base assembly's release lever, and release the connections between bases. e Mount the valve base assembly to be added on the DIN rail shown in Fig. 2. r Return the release lever of the piping block assembly disassembled in Step w to its original position, as shown in Fig. 3. Put the release levers on the additional valve bases in the same position, and press all the bases together until they click into place, all the while watching to ensure that lead wires are not caught by the cover. t Press the bases together from both sides to ensure that there is no gap between them, and then tighten the end block fixing screws, and fix the units in place on the DIN rail (see Fig. 5). Tightening torque: 128N・cm {13kgf・cm} Notes: 1. Always follow the steps shown in Fig. 4 when tightening the end block fixing screws for the F15 series. 2. Confirm that the DIN rail mounting hooks are securely attached to the DIN rail. (see Fig. 5). Figure 3 Figure 4 ●Tightening order of screws(for F15 series only) A B A B A B 3 1 4 Pressing down lightly on the release lever will return it to its forward position. Figure 5 ●Fixing the end block in place Tighten the screw with the L-shaped hook pushed in. 5 2 6 Always tighten the middle fixing screw of each end block first. Tightening torque: 128N・cm {13kgf・cm} ●Removing the end block from the DIN rail w DIN rail Use hooks on both sides to fix the DIN rail in place. q For mounting, follow in reverse the steps taken for removal. Caution: The new end block for the F10 series does not include an L-shaped hook.To remove the end block from the DIN rail, loosen the end block fixing screws, and lift it off. (The switch to the new type will commence in October 2000) 520 q Use a minus screwdriver to open all of the covers (see Fig. 1). Loosen the mounting screws of the valves next to the valve bases to be added, remove the valves, and remove the plug-in connectors. (see Fig. 6) w End terminal lead wires (short red wires) are inserted into pin insert section (No.3) of the plug-in connectors removed in step q. (see Fig. 7) (At time of delivery, end terminal lead wire is inserted into the plugin connectors of the end unit valve.) Remove this end terminal lead wire, and insert it into the insert section (No.3) of the plug-in connector for the valve base assembly to be added. Next, insert the common wire (red) of this plug-in connector into the insert section (No.3) of the removed plug-in connector. Figure 6 Plug-in connector Pull straight out Figure 7 Note: When inserting the lead wire, confirm that the short bar of the plugin connector's common wire insert section has been inserted. e Install each of the plug-in connectors wired in step w to the valve base, and mount the valve. r Remove the wiring block mounting screws and place them in the position shown in Fig. 8, then connect the lead wire (white) of the added valve base after confirming the pin location. (For details, see the detailed diagram of the wiring block internal connections on p. 524) t Return the connector brackets to their original position, and tighten the wiring block mounting screws in place, then close the cover while watching to ensure that the lead wires are not caught by the cover. Newly added plug-in connector ※1 End terminal lead wire (red) Plug-in connector Common wire (red) Lead wire (white) Common wire (red) End terminal lead wire (red) (Short, red wire) 【Caution】 ●Always cut off the power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. ●When removing lead wires from the plug-in connector, use an item with a fine tip (such as a small screwdriver) to press lightly on the contact hook section from a window on the side of the plug-in connector, and pull out the lead wire. If re-inserting the lead wire to the connector, spread the contact hooks so that they face outward, and then insert into the plug-in connector. At this time, pull lightly on the lead wire to confirm that it is securely inserted. ●Always connect the end terminal lead wires. (see Fig. 7). ●Be careful not to be caught or lose gaskets. ●Before supplying air to the manifold, always confirm that the bases are connected, and the end block fixing screws are tightened, etc. Supplying air when either of the end blocks are not securely fixed to the DIN rail could result in air leaks or in separated manifold bases. ●Be aware that the manifold is limited in the number of valve units that can be added, by the wiring specifications and wiring connection procedures, etc. For details, see the "Table for maximum number of valve units, by wiring specification," on p. 548. ●When there are large number of valves simultaneously supplying air to the secondary side, or when there is a large number of valve units, we recommend using two sources of air supply and exhaust (on each side). ※2 Replace the end terminal lead wires Lead wire (white) ※2 ※1: Always insert end terminal lead wires. ※2: Shows when both A and B are used. Figure 8 Mounting screw Connector bracket See "Detailed Diagram of Wiring Block Internal Connections" on p.524. Note that adding units of the piping block assembly is performed in the same way as adding units of the valve base assembly. In addition, when the wiring block and piping block are side-by-side, always mount the wiring block at the outside of the piping block, for structural reasons. Valve tightening torque N・cm {kgf・cm} Series Torque F10 17.6 {1.8} F15 49.0 {5.0} 521 SOLENOID VALVES F SERIES ■Wiring Procedure F18 Series Disassembly Diagram of Split Manifold Plug-in Type Figure 1 Disassembly example: For mounted flat cable connector Connecting bolt End block Additional side Additional position Piping block assembly Cover Valve base assembly Wiring block assembly Connecting rod End block Manifold Unit Adding Procedure (F18 Series Plug-in Type) ■Adding valve base unit Use the valve base assembly to add units. q Remove the connecting bolts on the end block and separate the end block from the manifold (see Fig. 1). w Install the connecting rods to be added, open up spaces where the units are being added, fit gaskets into the valve base assemblies being added, and place the units on top of the connecting rods. At this time, securely mount so that no clearance is left between the added valve base assemblies and the upper surface of the connecting rods. e Fit gaskets into the end blocks removed in Step q, and retighten the connecting bolts. At this time, use a hexagonal bar wrench to hold the connecting bolts on the opposite side in place so as to prevent the bolts from slipping while tightening them into place. Tightening torque: 147N・cm {15kgf・cm} 522 q Use a minus screwdriver to open all of the covers (see Fig. 1). Loosen the mounting screws of the valves next to the valve bases to be added, remove the valves, and remove the plug-in connectors. (see Fig. 2). w End terminal lead wire (short red wire) is inserted into pin insert section (No.3) of the removed plug-in connectors in step q. (see Fig. 3) (At time of delivery, end terminal lead wire is inserted into the plugin connectors of the end unit valve.) Remove this end terminal lead wire, and insert it into the insert section (No.3) of the plug-in connector for the valve base assembly to be added. Next, insert the common wire (red) of this plug-in connector into the insert section (No.3) of the removed plug-in connector. Note: When inserting the lead wire, confirm that the short bar of the plugin connector's common wire insert section has been inserted. e Install each of the plug-in connectors wired in step w to the valve base, and mount the valve. r Remove the wiring block mounting screws and place them in the position shown in Fig. 4, then connect the lead wire (white) of the added valve base after confirming the pin locations. (For details, see the detailed diagram of wiring block internal connections on p. 524) t Return the connector brackets to their original position, and fix the wiring block mounting screws in place, then close the cover while observing that the lead wires are not caught by the cover. Figure 2 Plug-in connector Pull straight out Figure 3 Newly added plug-in connector ※1 End terminal lead wire (red) Plug-in connector Common wire (red) Lead wire (white) Common wire (red) End terminal lead wire (red) (Short, red wire) 【Caution】 ●Always cut off power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. ●When removing lead wires from the plug-in connector, use an item with a fine tip (such as a small screwdriver) to press lightly on the contact hook from a window on the side of the plug-in connector, and pull out the lead wire. If re-inserting the lead wire to the connector, spread the contact hooks so that they face outward, and then insert into the plug-in connector. At this time, pull lightly on the lead wire to confirm that it is securely inserted. ● Always connect the end terminal lead wires. (see Fig. 3). ●Be careful not to be caught or lose gaskets. ●Before supplying air to the manifold, always confirm that the bases are connected, the end block connecting bolts on both sides are tightened, etc. Supplying air when either of the end blocks are not securely fixed in place could result in air leaks or in separated manifold bases. ●Be aware that the manifold is limited in the number of valve units that can be added, by the wiring specifications and wiring connection procedures, etc. For details, see the "Table for maximum number of valve units, by wiring specification," on p. 548. ●When there are large number of valves simultaneously supplying air to the secondary side, or when there is a large number of valve units, we recommend to use two sources of air supply and exhaust (on each side). ※2 Replace the end terminal lead wires Lead wire (white) ※2 ※1: Always insert end terminal lead wires. ※2: Shows when both A and B are used. Figure 4 SOLENOID VALVES F SERIES ■Wiring Procedure Mounting screw Connector bracket See "Detailed Diagram of Wiring Block Internal Connections" on p. 524. Note that adding units of the piping block assembly is conducted in the same way as adding units of the valve base assembly. In addition, when the wiring block and piping block are side-by-side, always mount the wiring block at the outside of the piping block, for structural reasons. Valve tightening torque N ・cm {kgf・cm} Series torque F18 49.0 {5.0} 523 Detailed Diagram of Wiring Block Internal Connections Flat cable connector 10, 20, 26 pins ● For -F100 ● For -F101 Locations with protruding part upward. Connection to power connecting terminal’s ( ) pole Locations with protruding part upward. Unused pin NC OM 7 C M NC O 5 C 8 3 Connection to power connecting 6 1 4 terminal’s (+) pole NC NC C 2 C N N NC C NC N NC Unused pin NC NC 7 5 8 3 6 1 4 NC NC C 2 C N N NC C NC N NC Unused pin Unused pin Connection to power connecting terminal’s (+) pole To plug-in connector Insert so that protruding part is catched. For the locations shown in the above illustration, for the upper part, insert the contact facing upward , and for lower part, insert the contact facing downward. Note: As shown in the illustration above, remove the connector and then perform the wiring. ● For -F200 Locations with protruding part upward. 15 13 6 1 11 9 2 14 7 0 1 1 5 8 3 6 1 4 2 ● For -F201 Connection to power connecting terminal’s (+) pole D sub connector ● For -F260 Locations with protruding part upward. Locations with protruding part upward. 1 2 1 3 1 1 4 1 2 1 3 15 4 16 5 17 18 7 6 8 Connection to power connecting terminal’s ( ) pole To plug-in connector Insert so that protruding part is catched. For the locations shown in the above illustration, for the upper part, insert the contact facing upward , and for lower part, insert the contact facing downward. To plug-in connector Connection to power connecting terminal’s ( ) pole Connection to power connecting terminal’s (+) pole To plug-in connector C 9 N 7 1 NC 5 1 20 1 8 13 6 1 Unused 1 11 9 2 14 pin 7 0 1 5 1 8 3 6 1 4 2 ● For -D250 ● For -D251 9 7 5 6 11 13 0 8 15 2 1 NC 14 1 C N 16 NC 3 4 1 2 Unused pin Insert into the added locations Connection to power connecting terminal’s ( ) pole Connection to power connecting terminal’s (+) pole 5 6 7 18 1 8 9 2 0 19 0 1 1 NC 22 2 23 2 3 4 15 14 6 71 1 Insert into the added locations Connection to power connecting terminal’s (+) pole Connection to power connecting terminal’s ( ) pole To plug-in connector ● For -T200 Locations with protruding part upward. OM 7C 5 1 NC 3 1 18 1 6 11 4 1 1 9 7 0 12 1 5 8 3 6 1 4 2 Note: As shown in the illustration above, remove the connector and then perform the wiring. 524 Connection to power connecting terminal’s ( ) pole To plug-in connector Unused pin Terminal block Connection to power connecting terminal’s (+) pole Manifold common wire Unused pin Insert so that protruding part is catched. For the locations shown in the above illustration, for the upper part, insert the contact facing upward , and for lower part, insert the contact facing downward. To plug-in connector To plug-in connector Product Configuration for the F Series Serial Transmission Compatible Manifold In ordering the serial transmission compatible manifold, note that the product configurations vary between the F10 and F15 series, and the F18 series. ■ For F10 and F15 series A B A B A B ● The manifold body and serial transmission block are connected by a flat cable, and mounted on one DIN rail at time of delivery. 〔Figure 1〕 D D ADDRESS 1 2 4 8 16 32 64 128 G 24V 0V POWER SEND YS201L YS2□L (For stand-alone, left-side mounting)※ YS2□R (For stand-alone, right-side mounting)※ YS391 (For Omron CompoBus/D)Note MADE IN JAPAN G 24V 0V 142160 Serial transmission block (Stand-alone type) ■ For Serial Transmission Block, Single Unit Manifold type solenoid valve (Common for standard manifold of F201 type wiring specification) F18 series A B A B ※: About 100mm of a flat cable with connector is provided with the serial transmission block. Note: The transmission block uses Omron's remote I/O adapter-type DRT1OD16X, and therefore differs in shape from other transmission blocks. Illustration shows the F10 series. A B 〔Figure 2〕 ● The serial transmission block is fixed to the manifold at time of delivery. D POWER SEND D ADDRESS 1 2 4 8 16 32 64 128 G 24V 0V Serial Transmission Block, Single Unit YS201S MADE IN JAPAN G 24V 0V 142160 YS2□S (For monoblock, left-side mounting)※ YS2□T (For monoblock, right-side mounting)※ YS391 (For Omron CompoBus/D)Note ※: Cables, etc., not provided with serial transmission block. Note: The transmission block uses Omron's remote I/O adapter-type DRT1OD16X, and therefore differs in shape from other transmission blocks. Serial transmission block (Monoblock type) ■Application Examples for Serial Transmission Block, Single Products (for reference) If manifolds with flat cable connectors sold in the past have F201 wiring specifications (with plus common specifications only), the serial transmission blocks (stand-alone type) YS2□L, YS391 or YS2□R in Figure 1 can be connected to the manifold to convert it into a serial transmission-compatible manifold. ●Connectable Manifolds • FM-SOLID MANIFOLD X80M and X88M Series • Solenoid valves F series (F10 and F15 series are the same, with the exception of the above-described manifold and DIN rail.) ●Connection example between serial transmission block (stand-alone type) and earlier type of manifold D Mounting dimensions for serial transmission block, single product (Scale 1/3, Unit mm) 75 (12.5) 4 25 4 20.5 P Serial Transmission Block, Single Unit YS2□L ( For stand-alone, left-side mounting)※ YS2□R (For stand-alone, right-side mounting)※ YS391 (For Omron CompoBus/D)Note 90 82 (For mounting DIN rail) 10 Manifold type solenoid valve (F201 wiring specification for plus common specifications only) 5.5 YS201L MADE IN JAPAN G 24V 0V φ4.4 R 35 D ADDRESS 1 2 4 8 16 32 64 128 G 24V 0V POWER SEND 142160 Serial transmission block (Stand-alone type) When ordering YS2□L or YS2□R as single unit, a DIN rail is included. PR Serial transmission block 10 ※: Flat cable with connector provided with serial transmission block. Note: The transmission block uses Omron's remote I/O adapter-type DRT1OD16X, and therefore differs in shape from other transmission blocks. 16 φ4.4 (For direct mounting) 7 50 525 SOLENOID VALVES F SERIES Manifold type solenoid valve (Manifold for serial transmission only) Specifications of Serial Transmission Compatible Manifold General Specifications Voltage Note: Internal wiring for the F10 and F15 series on the manifold side is the same as the wiring specification -F201 of the split-type manifold plug-in type. (flat cable connector type) DC24V ±10% Operating temperature range 5∼50˚C Vibration resistance 49.0m/s2 {5.0G} (Conforms to JIS C 0911) Shock resistance 98.1m/s2 {10.0G} (Conforms to JIS C0912) ● For details about specifications, see the user's manual. (See below) Serial Transmission Block, Terminal Block (LED) Names ●For UNI-WIRE ® System ●For Mitsubishi Electric MELSECNET/MINI-S3 ●For Omron SYSBUS Wire System Transmission block specification: -01 (16-point output), -02 (8-point output) Transmission block specification: -11 Transmission block specification: -21 ×10 7 8 5 6 24V 0V 4 5 6 D 7 8 G SD 24V 0V RDA RD 4 G 3 9 0 1 E 2 3 2 3 D 2 3 OFF RDB 1 2 3 4 5 6 0 1 E 7 8 9 5 6 3 ON 1 T/ R RUN ERR ADDRESS ×1 PWR RUN ERR POWER SEND Dip switch for various settings OFF ON ON SDA O N Rotary switch for station number setting 4 Address setting swtich SDB TERM SG FG 24V + 0V E. C. MODE switch LED names LED names Display Description POWER •Flashes during normal transmission. •Lights up or shut off during faulty transmission. SEND Remark Description PWR •Lights up when power is turned on. RUN •Lights up for normal data communication with master station. SD •Flashes during sending data. RD •Flashes during receiving data. ERR •Lights up when data receiving error occurs. Shut off for normal communication. ® ※UNI-WIRE System is a serial parallel transmission system developed jointly by NKE and Kuroda Precision Industries. For details about UNI-WIRE System, see the NKE or Kuroda Precision Industries catalog, user's manual, etc. ● Number of output points per block 16 solenoids (transmission block specification: -01) 8 solenoids (transmission block specification: -02) ● Related materials: User's manual, document No.HV005 Remark ● Master station: MELSEC-A series AJ71PT32-S3, AJ71T32-S3, A2CCPU/A2CJCPU, A1SJ71PT32-S3, link sub-stations up to a maximum of 64 stations, and link I/O points up to a maximum of 512 points. ※For details, see Mitsubishi Electric's sequencer MELSEC-A series catalog, user's manual, etc. ● Number of output points per block Maximum of 16 solenoids ※Since the block is equivalent to two stations, if the block is entirely composed of sub-stations, the maximum becomes 32 units. ● Related FG 24V 0V End station setting switch LED names Display •Lights up when power is turned on. •Flashes during voltage drops or over current (a short circuit). − Display Description • Lights up when transmission is normal, and the PC RUN is in operations mode or monitor mode. •Flashes during normal transmission. •Lights up during standby or faulty transmission. •Shut off during faults (during watchdog timer fault). T/R ERR Remark ● Parent station unit: SYSMAC-C (CV) series C200H-RM201, C500-RM201 ※ For details, see Omron's programmable controller SYSMAC C(CV) series catalog, user's manual, etc. ● Number of output points per block Maximum of 16 solenoids ● Related materials: User's manual, document No.HV007 materials: User's manual, document No.HV006 ●For Omron B7A Link Terminal ●For Koyo Electronics Industries SA Bus ●For Sunx S-LINK Transmission block specification: -31 (standard type), -32 (high-speed type) Transmission block specification: -41 (16-point output), -42 (8-point output) Transmission block specification: -51 (16-point output), -52 (8-point output) Station number setting switch Output selecting switch in faulty operation 1 2 3 4 5 6 7 8 PWR ERR LOAD OFF ON PWR ERR POWER SEND 1 ERR SIG 0V LED names Display L+ L- SHLD L24V LED names Description Display •Lights up when power is turned on. PWR •Lights up when power is turned on. ERR •Lights up during faulty transmission. ERR •Lights up during faulty transmission or other faults. Remark ● Connection method: 1 to 1 (Transmission block specification) Standard type (-31) High speed type (-32) Max.31ms Max.5ms Transmission delay time Transmission distance Max.500m Max.100m ※For details about the B7A Link Terminal, see the Omron catalog, user's manual, etc. ● Number of output points per block Maximum of 16 solenoids ● Error output specifications Output mode: NPN open collector Rated load voltage: DC24V Output current: Sink current MAX. 40mA materials: User's manual, document No.HV008 G D 0V 2 3 24V 4 5 6 G 7 8 D 0V 24V LED names Description PWR 526 ON HOLD 24V ● Related Switch for address setting and manipulating output setting during error occurrence Display Description POWER •Lights up when power is turned on. SEND •Flashes during normal transmission. •Lights up or shut off during faulty transmission. Remark ※ For details about the SA Bus system, see the Koyo Electronics Industries catalog, user's manual, etc. ● Number of output points per block 16 solenoids (transmission block specification: -41) 8 solenoids (transmission block specification: -42) ● Related materials: User's manual, document No.HV009 Remark ※For details about the S-LINK System, see the Sunx catalog, user's manual, etc. ● Number of output points per block 16 solenoids (transmission block specification: -51) 8 solenoids (transmission block specification: -52) ● Related materials: User's manual, document No.HV010 ●For Mitsubishi Electric MELSEC I/O LINK ●For Fuji Electric T Link Mini ●For Keyence KZ-R Transmission block specification: -61 Transmission block specification: -71 Transmission block specification: -81 24V 0V S1 POWER/ERROR 3 SD FG 24V 0V S+ 7 8 9A LED names Display PW Description •Lights up when power is turned on. •Lights up when data transmitted from master unit is normal. RUN RUN Display Description PWR •Lights up when power is turned on. ALM •Lights up during faulty transmission. •Lights up during sending data to master unit. RD •Lights up during receiving data from master unit. ※ For details about the T Link Mini, see the Fuji Electric catalog, user's manual, etc. ERR. •Lights up when faulty data transmitted from master unit. ● Number Display 0V Description •Green : Lights up for normal communications status. •Orange : Lights up when communications status is poor. (Can also light up when address settings are different) •Red : Lights up during faulty operation, or when transmission is cut off. POWER/ ERROR of output points per block Maximum of 16 solenoids materials: User's manual, document No.HV012 ● 16 remote I/O unit connection stations, for a maximum of 128 control input/output points ※For details, see Mitsubishi Electric's sequencer catalog, user's manual, etc. Remark ※For details about KZ-R, see the Keyence catalog, user's manual, etc. ● Number of output points per block Maximum of 16 solenoids ● Number of output points per block Maximum of 16 solenoids ※Since the block is equivalent to four stations, if the block is entirely composed of sub-stations, a maximum of four units can connect to one master unit. ● Related materials: User's manual, document No.HV013 materials: User's manual, document No.HV011 ● For Omron CompoBus /D ● For Omron CompoBus/S ●For Mitsubishi Electric CC-Link Transmission block specification: -91 Transmission block specification: -A1 (16-point output), -A2 (8-point output) Transmission block specification: -B1 B RATE 8 ● 8 ● 8 6 1 2 3 4 5 6 ● ● RD +24V (FG) SLD DG DB DA Red PWR Shut off •No setting status Lights up COMM Shut off •Serious breakdown •Minor breakdown Shut off •No power supply Lights up ERR LED names State Display color Lights up •Normal status Shut off Green Yellow Red Description •During power supply. •When power is not supplied. •Communication fault, or standby. •Communication fault occurred. Remark Lights up •Serious communication fault. ※ For details about CompoBus/S, see the Omron catalog, user's manual, etc. Red •Minor communication fault. Shut off •No power supply. ※ For details about CompoBus/D, see the Omron catalog, user's manual, etc. The transmission block is Omron's remote adaptor-type DRT1-OD16X. For details about handling, see Omron's user's manual. ● Number of output points per block Maximum of 16 solenoids ● Number of output points per block 16 solenoids (transmission block specification: -A1) 8 solenoids (transmission block specification: -A2) ● Related •Lights up when power is turned on. L RUN materials: User's manual, document No.HV015 •Lights up when normal data is received from master station. SD •Lights up for data sending. RD •Lights up for data receiving. L ERR. •Communication connection achieved. Flashing Description PW •During normal communication, or standby. •No communication connection. Green Display •During normal communication. Flashing Remark ● 4 NS 6 Green Description Flashing Lights up ● Lights up ● HOLD/CLEAR switch LED names Display State Display color Flashing MS 24G FG 4 LED names Lights up BS− 0 ON Transmission Internal circuit power supply terminal connector Display BDL ● ● 10 ● ● BS+ BDH 1 0 2 SD ● 2 NS CLEAR ● ● MS HOLD 0 6 O N ×10 ● 2 Dip switch STATION NO. ×1 PW L RUN L ERR. ● PWR COMM ERR Transmission speed setting switch Station number setting switch 4 Dip switch for various settings •Lights up for transmission error, and shut off for time over. Lights up for station number setting error or transmission speed setting error. Remark ※For details about CC-Link, see the Mitsubishi Electric catalog, user's manual, etc. ● Number of output points per block 16 solenoids ※Since the block occupies one station, if the block is entirely composed of remote I/O stations, a maximum of 64 units can connect to one master station. ● Related materials: User's manual, document No.HV016 Related materials: User's manual, document No.HV014 ■ For details about specifications and handling, see the above-listed user's manuals (document No. HV005∼HV016). 527 SOLENOID VALVES F SERIES ● Related 24V Error holding swtich Remark ● Related FG LED names SD Remark 0 1 E S− ON/OFF switch for end terminal resistance LED names 9 ERROR MODE HOLD CLEAR OFF S2 ADDRESS 0 1 E 7 8 7 8 5 6 FG 4 DG 9 2 3 ON RD 3 7 8 0 1 E 2 3 BCDE 9 2 3 DATA 3 3456 SD PWR ALM E 2 F01 5 6 3 4 ST. NO. RUN ERR. Address setting switch 5 6 PW Station number setting switch ADDRESS ×10 ×1 4 Station number setting switch Precautions for Use Due to Partial Specification Change (Deliveries from January 30, 1997) ■Description of Changes Offering more durability and improved reliability, the coil dimensions have been changed. Therefore, to identify between the earlier and new types due to a partial change in manifold dimensions, parts of the outward color have been changed. 1.Changes in Single Valve Unit (Common to F10, F15, and F18 Series) q S Type Plug Connector Change 1 The coil is 5mm longer, and the valve total length becomes also 5mm longer. Change 2 The connector location has been moved 2.5mm to the center. Change 3 To identify between new and earlier types, the color of the manual override on the coil side has been changed from pink to light blue. Unit mm Earlier New ※Illustration shows the F10 series. Change 2 2.5 The connector location has been moved 2.5 mm to the center. Change 1 The valve total length is 5mm longer. Note F10:105 F15:125.5 F18:138.5 Manual override:Pink The coil is 5mm longer. F10:110 F15:130.5 F18:143.5 Manual override:Light blue Change 3 The color of the manual override on the coil side has been changed from pink to light blue. Note: The valve length is longer toward the coil side when mounting on the manifold. w L Type Plug Connector Change 1 The coil is 5mm longer, the valve total length becomes also 5mm longer. Change 2 The connector section now becomes 3mm longer. Change 3 To identify between new and earlier types, the color of the manual override on the coil side has been changed from pink to light blue. Unit mm Earlier New ※Illustration shows the F10 series. 43.5 Change 2 3 40.5 Change 1 The valve total length is 5mm longer.Note F10:94 F15:114.5 F18:127.5 Manual override:Pink The connector section now becomes 3mm longer. The coil is 5mm longer. F10:99 F15:119.5 F18:132.5 Manual override:Light blue Change 3 The color of the manual override on the coil side has been changed from pink to light blue. Note: The valve length is longer toward the coil side when mounting on the manifold. 2.Change in Connector Receptacle Shape of Plug-in Type Manifold (Common to F10, F15, and F18 Series) ■Target Products: Split Manifold Plug-in Type, and Serial Transmission Compatible Manifold Change 1 Connector receptacle position for valve assembly became 3mm deeper due to the change in the valve's L type plug connector. Change 2 To identify between new and earlier types, the color of the valve assembly cover has been changed from ivory to light blue. New Earlier ※Illustration shows the F10 series. Change 1 The plug-in connector location is 3mm deeper. Change 2 The color of the valve assemble cover has been changed. Cover Color: Ivory 528 Cover Color: light blue ■Precautions for Valve Replacement 1.About Combined Mountings of New and Earlier Types of Valves, and Manifolds ●For split-type manifolds plug-in type, and the serial transmission compatible manifolds, a change in the connector receptacle brings up some issues when combining earlier and new types of mounting valves and combination of the valves and manifolds on replacing the valves. For details about earlier and new combinations, see the table below. ● Since split manifolds non-plug-in type, and monoblock manifolds and PC board manifolds, do not have plug-in construction, consequently all combinations of earlier and new types are acceptable. ※Illustration shows the F10 series. Valve Earlier Manifold Color of manual override on coil side: Pink New Mounting screw Caution Sub-plate is required (Service parts) Earlier Color of cover on the valve base assembly: Ivory Earlier type Earlier type Cover Color: Ivory Cover Color: Ivory Caution: The sub-plate shown in the illustration above is required to align the heights in the connector section. Always attach a sub-plate to mount the valve. Note that the valve height is 3mm higher than the earlier type, and that the valve length on the coil side is 5mm longer. ●● Targeted products New type Manual override color: Light blue Mounting screw (3mm longer screw provided with sub-plate) Mounting screw Mounting screw New type Earlier type Manual override Color: Pink SOLENOID VALVES F SERIES Serial transmission compatible manifold Split manifold plug-in type Earlier type Manual override Color: Pink Color of manual override on coil side: Light blue Manual override Color: Light blue Caution New Color of cover on the valve base assembly: light blue New type New type Cover Color: Light blue Cover Color: Light blue The change in connector receptacle prevents the connector section from connecting firmly, resulting in poor contact. Caution: Sub-plate not required. Use of a sub-plate prevents the connector section from connecting firmly, resulting in poor contact. 2.Sub-plate (Service Parts) The sub-plate is provided as a service part, necessary to mount the new type valves on the earlier type split manifold plug-in type and on the earlier type serial transmission compatible manifold. Sub-plate (Sub-plate, gasket, O ring, 2 mounting screws) F Z-S Valve size 10 : 10mm width 15 : 15mm width 18 : 18mm width 529 530 F Series Order Code The solenoid valves F series order codes are classified into the following 8 categories. For details on order codes, see the designated pages. F T :Single valve unit Koganei solenoid valves F series p. 532 M□A:Monoblock manifold A type (base piping type) ● 10 :10mm width (Effective area 5mm2) ● 15 :15mm width (Effective area10mm2) ● 18 :18mm width (Effective area18mm2) p. 534 M□F:Monoblock manifold F type (direct piping type) p. 536 M□AP:PC board manifold A type (base piping type) p. 538 M□FP:PC board manifold F type (direct piping type) p. 540 M□N:Split manifold non-plug-in type p. 542 M□P:Split manifold plug-in type p. 546 M□S:Serial transmission compatible manifold p. 550 531 SOLENOID VALVES F SERIES Valve size Single Valve Unit Order Code ■Valve size 10mm width ■Operation method ■Valve specification 2-position single solenoid specification (for single solenoid only) 4 (A) Internal pilot type Effective area 10mm2 External pilot typeNote (for positive pressure) T0 4 (A) 5 (R1) 2 (B) 1 (P) External pilot typeNote (for vacuum)※ ※: This is a vacuum valve. Note: When using as a single unit, select -A2 (A type with sub-base) for the valve output type. Without a subbase, piping for the external pilot cannot be available. 3 ( R 2) 18mm width Effective area 18mm2 T1 2-position double solenoid specification (for both single and double solenoid types) 4 (A) 5 (R1) 2 (B) 1 (P) A type with plate T2 Manual override 4 (A) 5 (R1) 2 (B) 1 (P) A type with subbase -A2 -FJ5 Output port fitting F10:φ4 F15:φ6 F18:φ8 With output port single size fitting block Blank -FJ6 Manual lever override (made to order) Note1 3-position (ABR connection) 4 (A) 5 (R1) 2 (B) 1 (P) -R 3 ( R 2) Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 With output port female thread block With input port female thread block -F4 Output port F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 With output port single size fitting block With input port female thread block Output port fitting F10:φ6 F15:φ8 F18:φ10 Output port fitting F10:φ4 F15:φ6 F18:φ8 With output port female thread block With output port single size fitting block With input port female thread block -FM 4 (A) 5 (R1) 2 (B) 1 (P) F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 3 ( R 2) -F6 Output port fitting F10:φ6 F15:φ8 F18:φ10 T5 F10 F15 F18 Operation method Manual override Valve output type Wiring specification Blank Note2 T1 -A1 Note2 -FM Note2 -PN Blank -A2 -F3 Note3 -PS -R Note1 -FJ Note2 -F4 Note3 -PL Blank G T3 T4 Note4 T5 Note4 S type plug connector Lead wire 300mm -PS L type plug connector Lead wire 300mm -PL S type plug connector Lead wire 3000mm L type plug connector Lead wire 3000mm -PL3 T0 T2 S type plug connector Without connector -PS3 3-position (PAB connection) Valve specification Blank -F5 T4 Valve size L type plug connector Without connector -PN 3 ( R 2) T3 -F3 -A1 Output port F10:Rc1/8 F15:Rc1/8 F18:Rc1/4 3-position (all port block) Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 With output port single size fitting block ■Manual override 3 ( R 2) F18 -FJ Blank V 2-position single solenoid specification (for both single and double solenoid types) F15 ■Wiring specification G 1 (P) 3 ( R 2) 15mm width With output port different size fitting block With output port different size fitting block With input port female thread block 5 (R1) 2 (B) F10 Without input/ output block Blank Effective area 5mm2 ■Valve output type V Blank -FJ5 Note2 -F5 Note3 -PS3 Note2 -F6 Note3 -PL3 -FJ6 Voltage DC24V DC12V AC100V Notes: 1. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is available for the A side only. 2. Two manifold mounting screws are included. 3. The units with input port female thread block can be used only when the operation method is the internal pilot type valve. 4. Not available for the vacuum valve. 532 Additional Parts Order Code for Single Valve Unit ● For internal pilot F Z - Valve size 10:10mm width 15:15mm width 18:18mm width Parts content 21 : Mounting bracket (mounting bracket, 2 mounting screws) 25 : Sub-base (sub-base body, gasket, exhaust valve) Note 1 P : Plate (plate, gasket, 2 mounting screws) J : Different size fitting block (fitting block, gasket, 2 mounting screws) J5 : Single size fitting block F10: φ4, F15: φ6, F18: φ8 (fitting block, gasket, 2 mounting screws) J6 : Single size fitting block F10: φ6, F15: φ8, F18: φ10 (fitting block, gasket, 2 mounting screws) M : Female thread block (female thread block, gasket, 2 mounting screws) MP : P port female thread block (P port female thread block, gasket) Note 1 GS1 : Gasket (gasket, exhaust valve) Note 2 Notes: 1. Valve mounting screws are not included. 2. Be aware that this gasket is different from the GS2 gasket for the split-type manifolds. Sub-base for external pilot ●For external pilot F Z - Valve size 10:10mm width 15:15mm width 18:18mm width F Parts content P : Plate (plate, gasket, 2 mounting screws) J : Different size fitting block (fitting block, gasket, 2 mounting screws) J5 : Single size fitting block F10: φ4, F15: φ6, F18: φ8 (fitting block, gasket, 2 mounting screws) J6 : Single size fitting block F10: φ6, F15: φ8, F18: φ10 (fitting block, gasket, 2 mounting screws) M : Female thread block (female thread block, gasket, 2 mounting screws) GS1 : Gasket (gasket, exhaust valve) Note 2 ZG - 25 Valve size 10:10mm width 15:15mm width 18:18mm width Notes: Be aware that this gasket is different from the GS2 gasket for the split type manifolds. Connector-related order code Valve specification For T1, T2, T3, T4, T5 FZ0 Connector specification CP : Connector, lead wire length 300mm (black, red, white, for total of 3 lead wires) CP3 : Connector, lead wire length 3000mm (black, red, white, for total of 3 lead wires) CLN : Connector without lead wire (1 short bar and 3 contacts included) CC1.5 : Cabtire cable, length 1500mm ※ CC3 : Cabtire cable, length 3000mm ※ Valve specification For T0 Connector specification CP : Connector, lead wire length 300mm (black, red, for total of 2 lead wires) CP3 : Connector, lead wire length 3000mm (black, red, for total of 2 lead wires) CLN : Connector without lead wire (1 short bar, 2 contacts included) ※For details, see p. 513. Exhaust valve 25:Sub-base GS1:Gasket MP:P port female thread block P:Plate M:Female thread block J, J5, J6:Fitting block 21:Mounting bracket 533 SOLENOID VALVES F SERIES FZ - Monoblock Manifold A Type (Base Piping) Order Code ■Valve size ■Operation method F10M Blank Internal pilot typeNote4 10mm width Effective area 5mm2 F15M G 15mm width Effective area 10mm2 External pilot typeNote5 (for positive pressure) F18M 18mm width Effective area 18mm2 V ■Manifold output specification With single size fitting block (base piping type) With different size fitting block (base piping type) External pilot typeNote5 (for vacuum)※ ※: This is a vacuum valve. Note: Cannot be combined with a positive pressure valve. ■Individual air supply and exhaust spacer Plus common prewiring connection Blank : Without spacer L type plug connector S type plug connector -NPM : Individual air supply spacer (with M5 Lead wire 300mm Without connector female thread for F10) -NP6 : Individual air supply spacer (with φ6 fitting for F15) -NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) -NP0 : Individual air supply spacer (with φ10 fitting for F18) Blank -CPS -NRM : Individual exhaust spacer (with M5 female thread for F10) S type plug connector Plus common pre-NR6 : Individual exhaust spacer (with φ6 fitting wiring connection Without connector for F15) L type plug connector -NR8 : Individual exhaust spacer (with φ8 fitting Lead wire 300mm for F15 and F18) -NR0 : Individual exhaust spacer (with φ10 fitting for F18) For details, see p.516. ■Wiring specification -PN J ■Manual override L Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 Output port fitting F10:φ4 or φ6 F15:φ6 or φ8 F18:φ8 or φ10 S type plug connector Lead wire 300mm Manual override With female thread block (base piping type) -CPL Plus common prewiring connection S type plug connector Lead wire 3000mm ■Manifold fitting specification Manifold side output port single fitting -PS Blank L type plug connector Lead wire 300mm Manual lever override (made to order) Note2 M Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 -CPS3 Plus common prewiring connection L type plug connector Lead wire 3000mm -J5 Output port fitting F10:φ4 F15:φ6 F18:φ8 Manifold side output port single fitting -PL S type plug connector Lead wire 3000mm -R ■Valve specification -CPL3 T0 : 2-position, for single solenoid only T1 : 2-position, single solenoid specification T2 : 2-position, double solenoid specification T3 : 3-position, all port block T4 : 3-position, ABR connection T5 : 3-position, PAB connection -J6 ■ Valve output type Output port fitting F10:φ6 F15:φ8 F18:φ10 -PS3 With plate Note 3 (base piping type) L type plug connector Lead wire 3000mm ■Pilot specification -A1 Blank Internal pilot manifold -PL3 G External pilot manifold Note: Valves of different sizes can not be combined together for mounting. Valve size Valve units Manifold output specification Pilot specification Station Valve size Valve specification Operation Manual method override Manifold model M F15M F18M 2 ・ ・ ・ 20 Wiring specification Manifold fitting specification Individual air supply and exhaust spacer Voltage Mounting valve models J F10M Valve output type Blank G stn. 1 ・ ・ ・ stn.□ F10 F15 T0 T3 T1 T4Note6 G Note5 T2 T5Note6 V Note5 F18 Blank Note4 Blank Blank -R Note2 Note1 -A1 Note3 -PN -PS -PL -PS3 -PL3 Blank -CPS -CPL -CPS3 -CPL3 -NPM -NP6 -NP8 -NP0 -NRM -NR6 -NR8 -NR0 DC24V DC12V AC100V BP (for block-off plate) A Blank Note4 L Blank G stn. 1 ・ ・ ・ stn.□ Note1 F10 F15 T0 T3 T1 T4Note6 G Note5 T2 T5Note6 V Note5 Blank Blank -R Note2 -A1 Note3 F18 -PN -PS -PL -PS3 -PL3 -CPS -CPL -CPS3 -CPL3 Blank -J5 -J6 -NPM -NP6 -NP8 -NP0 -NRM -NR6 -NR8 -NR0 DC24V DC12V AC100V BP (for block-off plate) Notes: 1. Valve mounting location from the left, with the solenoid on top, and A and B ports front. 2. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. 3. Always enter -A1. 4. Cannot be mounted on the external pilot manifold. 534 5. Cannot be mounted on the internal pilot manifold. 6. Not available for the vacuum valve. Additional Parts Order Code for Monoblock Manifold A Type Gasket (gasket and exhaust valve) F Z - GS1 Valve size 10:10mm width 15:15mm width 18:18mm width GS1:Gasket BP:Block-off plate Block-off plate (block-off plate and 2 mounting screws) F BP Valve size 10:10mm width 15:15mm width 18:18mm width Connector-related order code FZ - Connector specification CP : Connector, lead wire length 300mm Blank : For T1, T2, CP3 : Connector, lead wire length 3000mm CLN : Connector without lead wire (short bar T3, T4, T5 and contacts included) 0 : For T0 PA : Plus common A type, lead wire length 300mm ※ PA3 : Plus common A type, lead wire length 3000mm ※ ※For details, see PB : Plus common B type, lead wire length 300mm ※ p.513. PB3 : Plus common B type, lead wire length 3000mm ※ PC : Plus common C type, lead wire length 300mm ※ PC3 : Plus common C type, lead wire length 3000mm ※ CC1.5 : Cabtire cable, length 1500mm Note ※ CC3 : Cabtire cable, length 3000mm Note ※ Note: Not available for T0. Valve specification Red Common wire (+) Black A side (–) White B side (–) (Insert when using as double solenoid) C type:FZ-PC□※ Red Common wire (+) Black A side (–) White B side (–) (Insert when using as double solenoid) Red Black White Red Common wire (+) A side (–) B side (–) (Insert when using as double solenoid) Common wire (+) ※: Lead wire length Blank: 300mm 3: 3000mm Note: White lead wire is not available for FZ0-P□ □. F Z - Note Valve size 10:10mm width 15:15mm width Note 18:18mm width Note Specification NPM : NP6 : NP8 : NP0 : NRM : NR6 : NR8 : NR0 : Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15 and F18) Individual air supply spacer (with φ10 fitting for F18) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15 and F18) Individual exhaust spacer (with φ10 fitting for F18) ※For details, see p.516. Muffler KM - J Manifold Order Code Example (6 units of F10 Series) F10M6AL stn.1∼ 2 F10T0-A1-PS-J5 DC24V stn.3∼ 5 F10T2-A1-PS-J6 DC24V stn.6 F10BP-J6 Note: This order code example has no relation to the illustration at upper right. Fitting size 6 : Outer diameter φ 6 (for individual exhaust spacer) 8 : Outer diameter φ 8 (for individual exhaust spacer) 10 : Outer diameter φ 10 (for individual exhaust spacer) (Sales unit: Set of 10 mufflers) Precautions for Order Code ●Manifold output specification Select either “with fitting block” or “with female thread block.” For repair or replacement, purchase the single valve unit additional parts, F□ Z-J (different size fitting block), F□ Z-J□ (single size fitting block), or F□ Z-M (female thread block), on p. 533. ● Orders for valves only Place orders from “Single Valve Unit Order Code” on p. 532. Note, however, that the only compatible valve type is A1. In addition, for common terminal wiring connections, order separately the common connector assemblies listed above. 535 SOLENOID VALVES F SERIES for non-plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws ) :FZ-PA□※ B type :FZ-PB□※ For external pilot Individual air supply and exhaust spacer ●Common connector assembly A type Exhaust valve Monoblock Manifold F Type (Direct Piping) Order Code ■Valve size ■Valve output type F10M With different size fitting block (direct piping type) 10mm width ■Wiring specification L type plug connector Without connector Plus common prewiring connection S type plug connector Lead wire 300mm Effective area 5mm2 F15M 15mm width -FJ Effective area 10mm2 Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 F18M 18mm width Effective area 18mm2 -CPS Blank S type plug connector Without connector Plus common prewiring connection L type plug connector Lead wire 300mm With output port single size fitting block (direct piping type) ■Valve specification -PN T0 : 2-position, for single solenoid only T1 : 2-position, single solenoid specification -FJ5 T2 : 2-position, double solenoid specification Output port fitting T3 : 3-position, all port block F10:φ4 T4 : 3-position, ABR connection F15:φ6 T5 : 3-position, PAB connection F18:φ8 With output port single size fitting block (direct piping type) ■Manual override S type plug connector Lead wire 300mm -CPL Plus common prewiring connection S type plug connector Lead wire 3000mm -PS L type plug connector Lead wire 300mm -CPS3 Plus common prewiring connection L type plug connector Lead wire 3000mm Manual override -FJ6 -PL Output port fitting F10:φ6 F15:φ8 F18:φ10 Blank S type plug connector Lead wire 3000mm -CPL3 With female thread block (direct piping type) Manual lever override (made to order) Note2 -PS3 -R L type plug connector Lead wire 3000mm -FM Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 ■Individual air supply and exhaust spacer Blank : Without spacer -NPM : Individual air supply spacer (with M5 female thread for F10) -NP6 : Individual air supply spacer (with φ6 fitting for F15) -NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) -NP0 : Individual air supply spacer (with φ10 fitting for F18) -NRM : Individual exhaust spacer (with M5 female thread for F10) -NR6 : Individual exhaust spacer (with φ6 fitting for F15) -NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) -NR0 : Individual exhaust spacer (with φ10 fitting for F18) For details, see p.516. -PL3 Note: Valves of different sizes can not be combined together for mounting. Valve size Valve units Station Valve size Valve specification Manifold model Manual override Valve output type Wiring specification F15M F18M 2 ・ ・ ・ 20 Voltage Mounting valve models Blank F10M Individual air supply and exhaust spacer F stn. 1 ・ ・ ・ stn.□ Note1 F10 F15 F18 T0 T3 T1 T4 T2 T5 -FJ Blank -FJ5 -R Note 2 -FJ6 -FM -PN -PS -PL -PS3 -PL3 Blank -CPS -CPL -CPS3 -CPL3 -NPM -NRM DC24V -NP6 -NR6 DC12V -NP8 -NR8 AC100V -NP0 -NR0 BP (for block-off plate) Notes 1: Valve mounting location from the left, with solenoid on top, and A and B ports front. 2: The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. Remark: The external pilot valve cannot be mounted on the F type manifold. 536 Additional Parts Order Code for Monoblock Manifold F Type Gasket (gasket and exhaust valve) F Z - GS1 Valve size 10:10mm width 15:15mm width 18:18mm width GS1:Gasket BP:Block-off plate Block-off plate (block-off plate and 2 mounting screws) F BP Valve size 10:10mm width 15:15mm width 18:18mm width Connector-related order code - Valve specification Blank: For T1, T2, T3, T4, T5 0: For T0 ※For details, see p.513. Connector specification CP : Connector, lead wire length 300mm CP3 : Connector, lead wire length 3000mm CLN : Connector without lead wire (short bar, contacts included) PA : Plus common A type, lead wire length 300mm ※ PA3 : Plus common A type, lead wire length 3000mm ※ PB : Plus common B type, lead wire length 300mm ※ PB3 : Plus common B type, lead wire length 3000mm ※ PC : Plus common C type, lead wire length 300mm ※ PC3 : Plus common C type, lead wire length 3000mm ※ CC1.5 : Cabtire cable, length 1500mm Note ※ CC3 : Cabtire cable, length 3000mm Note ※ Note: Not available for T0. Exhaust valve Individual air supply and exhaust spacer for non-plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws ) ●Common connector assembly A type:FZ-PA□※ Red Common wire (+) Black A side (–) White B side (–) (Insert when using as double solenoid) B type:FZ-PB□※ C type:FZ-PC□※ Red Common wire (+) Black A side (–) White B side (–) (Insert when using as double solenoid) Red Black White Red Common wire (+) A side (–) B side (–) (Insert when using as double solenoid) Common wire (+) ※: Lead wire length Blank: 300mm 3: 3000mm Note: White lead wire is not available for FZ0-P□ □. F Z - Note Note Note Valve size 10:10mm width 15:15mm width 18:18mm width Specification NPM : NP6 : NP8 : NP0 : NRM : NR6 : NR8 : NR0 : Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15 and F18) Individual air supply spacer (with φ10 fitting for F18) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15 and F18) Individual exhaust spacer (with φ10 fitting for F18) ※For details, see p. 516. Muffler KM - J Manifold Order Code Example (4 units of F10 Series) F10M4F stn.1 ∼ 2 F10T0-FJ5-PS DC24V stn.3 F10T2-FJ6-PS DC24V stn.4 F10BP Note: This order code example has no relation to the illustration at upper right. Fitting size 6 : Outer diameter φ6 (for individual exhaust spacer) 8 : Outer diameter φ8 (for individual exhaust spacer) 10 : Outer diameter φ10 (for individual exhaust spacer) (Sales unit: Set of 10 mufflers) Precautions for Order Code ● Orders for valves only Place orders from “Single Valve Unit Order Code” on p. 532. Select from valve types -FJ, -FJ5, -FJ6, or -FM. In addition, for common terminal wiring connections, order separately the common connector assemblies listed above. 537 SOLENOID VALVES F SERIES FZ PC Board Manifold A Type (Base Piping) Order Code ■ Manifold output specification With different size fitting block (base piping type) ■Pilot specification ■Wiring connection specification Blank ■Individual air supply and exhaust spacer Blank : Without spacer -NPM : Individual air supply spacer (with M5 female thread for F10) -NP6 : Individual air supply spacer (with φ6 fitting for F15) -NP8 : Individual air supply spacer (with φ8 fitting for F15 ) -NRM : Individual exhaust spacer (with M5 female thread for F10) -NR6 : Individual exhaust spacer (with φ6 fitting for F15) -NR8 : Individual exhaust spacer (with φ8 fitting for F15) For details, see p.516. -S Internal pilot manifold Single wiring: Wiring as single solenoid only. Note: This is not the same as packed wiring. G -W External pilot manifold Double wiring: Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. J Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 ■ Wiring specification (wiring block) With female thread block (base piping type) ■Operation method Flat cable connector (with socket and strain relief) ■Manual override ■Valve output type ■Manifold fitting specification Note 9 Blank With plate (base piping type) Manual override Internal pilot type Note6 Manifold side output port single size fitting G M External pilot type Note7 (for positive pressure) -F20□ Output port female thread F10:M5×0.8 F15:Rc1/8 -J5 Output port fitting F10:φ4 F15:φ6 Manual lever override (made to order) Note8 External pilot type Note7 (for vacuum)※ ※: This is a vacuum valve. With single size fitting block (base piping type) -A1 Blank V -F200:20-pin -F201:20-pin For details, see p.558. ■Wiring specification S type plug connector Lead wire for PC board Note9 Note: Cannot be combined with a valve for positive pressure. Manifold side output port single size fitting -R L -J6 -PP Output port fitting F10:φ4 or φ6 F15:φ6 or φ8 Output port fitting F10:φ6 F15:φ8 ■Valve specification T0 : 2-position, for single solenoid only T1 : 2-position, single solenoid specification T2 : 2-position, double solenoid specification T3 : 3-position, all port block T4 : 3-position, ABR connection Note 10 T5 : 3-position, PAB connection Note 10 ■Valve size F10M 10mm width, Effective area 5mm2 F15M Note: Valves of different sizes can not be combined together for mounting. 15mm width, Effective area 10mm2 Valve size Valve units Manifold output specification Pilot Wiring specification specification Wiring connection specification Station Valve size Operation Manual method override Valve specification Double wiring type Note 2 Single wiring type Note 1 Manifold model 6 8 10 12 14 16 Wiring Manifold fitting type specification specification Individual air supply and exhaust spacer Voltage Mounting valve models J Blank -F200 M G -F201 -S stn. 1 ・ ・ ・ stn.□ F10 F15 Blank T0 T1 G Note7 V Note7 Note5 Note4 Blank Note6 Blank -R Note8 -A1 -PP Note9 Note9 -NPM -NRM DC24V -NP6 -NR6 DC12V -NP8 -NR8 BPC (for block-off plate) AP L Note3 Blank -F200 G -F201 -S stn. 1 ・ ・ ・ stn.□ F10 F15 Note4 F10M F15M J M 6 8 Valve output Blank G -F200 -F201 -W stn. 1 ・ ・ ・ stn.□ BlankNote6 T0 T1 G Note7 V Note7 Note5 Blank -R Note8 Blank -A1 -PP Note9 Note9 -J5 -J6 -NPM -NRM DC24V -NP6 -NR6 DC12V -NP8 -NR8 BPC (for block-off plate) F10 F15 Note4 T0 T3 T1 T4 Note10 T2 T5 Note10 BlankNote6 G Note7 V Note7 Blank -R Note8 -A1 Note9 Blank -NPM -NRM DC24V -NP6 -NR6 DC12V -NP8 -NR8 -PP Note9 Note11 BPC (for block-off plate) AP Note3 L Blank -F200 G -F201 -W stn. 1 ・ ・ ・ stn.□ Note4 F10 F15 T0 T3 T1 T4 Note10 T2 T5 Note10 BlankNote6 G Note7 V Note7 Blank -R Note8 -A1 Note9 -PP Note9 Note11 Blank -J5 -J6 -NPM -NRM DC24V -NP6 -NR6 DC12V -NP8 -NR8 BPC (for block-off plate) Notes: 1. Wiring as single solenoid only. Note that this is not the same as packed wiring. The mounting valves are limited to single solenoid only (T0, T1 specifications). Therefore, even if the T1 specification valve is switched over to a double solenoid, no current will be applied to the B side solenoid. 2. Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. 3. Number of units in terms of the wiring connection specifications are, for single wiring, 6 ~16 (even numbers only), and for double wiring, 6 or 8. 4. Valve mounting location from the left, with solenoid on top, and A and B ports front. 5. The mounting valves are limited to T0, T1 specifications only (single solenoid specifications). In addition, even if the T1 specification valve is switched over to a double solenoid, no current will be applied to the B side solenoid. 6. Cannot be mounted on the external pilot manifold. 7. Cannot be mounted on the internal pilot manifold. 8. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. 9. Always enter -A1 or -PP. 10. Not available for the vacuum valve. 11. Lead wire on solenoid B side (white) is not available for the valve specification T0. 538 Additional Parts Order Code for PC Board Manifold A Type Gasket (gasket and exhaust valve) F Z - GS1 GS1:Gasket Valve size 10:10mm width 15:15mm width BPC:Block-off plate Block-off plate (block-off plate, 2 mounting screws and housing) F BPC Valve size 10:10mm width 15:15mm width Connector-related order code FZ - Valve specification Blank: For T1, T2, T3, T4, T5 0: For T0 Connector specification P10 : For F10 series Connector lead wire for PC board manifold P15 : For F15 series Connector lead wire for PC board manifold Exhaust valve For external pilot Red Common wire (+) Housing※ Black Side A (–) White Side B (–) ※: Use as a cover when the block-off plate is attached. Note Note: White lead wire is not available for FZ0-P□. Individual air supply and exhaust spacer for non-plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws ) F Valve size 10:10mm width 15:15mm width Z Specification NPM NP6 NP8 NRM NR6 NR8 : : : : : : Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15) ※For details, see p.516. Manifold Order Code Example (8 units of F10 Series) Muffler KM - J F10M8APL-F201-W stn.1 ∼ 4 F10T0-A1-PP-J5 DC24V stn.5 ∼ 7 F10T2-A1-PP-J6 DC24V stn.8 F10BPC-J6 Note: This order code example has no relation to the illustration at upper right. Fitting size 6 : Outer diameter φ 6 (for individual exhaust spacer) 8 : Outer diameter φ 8 (for individual exhaust spacer) 10 : Outer diameter φ 10 (for individual exhaust spacer) (Sales unit: Set of 10 mufflers) Precautions for Order Code ● Orders for valves only Use the code Valve size Valve specification Pilot specification Manual override - Valve output type - PP Voltage to order. If the lead wire for PC board is not necessary, enter -PN. ● Wiring connection specification -S (single wiring): Wiring as single solenoid only. -W (double wiring): Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. 539 SOLENOID VALVES F SERIES (Insert when using as a double solenoid) PC Board Manifold F Type (Direct Piping) Order Code ■Valve size ■Manual override ■Valve output type Manual override With different size fitting block (direct piping type) F10M 10mm width ■Wiring specification With output port single size fitting block (direct piping type) S type plug connector Lead wire for PC board Effective area 5mm2 F15M 15mm width -FJ Blank Effective area 10mm2 Manual lever override (made to order) Note6 ■ Wiring specification (wiring block) Flat cable connector (with socket and strain relief) Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 With female thread block (direct piping type) -FJ5 -PP Output port fittings F10:φ4 F15:φ6 With output port single size fitting block (direct piping type) ■Individual air supply and exhaust spacer Blank : Without spacer -NPM : Individual air supply spacer (with M5 female thread for F10) -NP6 : Individual air supply spacer (with φ6 fitting for F15) -NP8 : Individual air supply spacer (with φ8 fitting for F15) -NRM : Individual exhaust spacer (with M5 female thread for F10) -NR6 : Individual exhaust spacer (with φ6 fitting for F15) -NR8 : Individual exhaust spacer (with φ8 fitting for F15) For details, see p.516. -R -FM Output port female thread F10:M5×0.8 F15:Rc1/8 -F20□ -FJ6 Output port fitting F10:φ6 F15:φ8 -F200:20-pin -F201:20-pin For details, see p. 558. ■Wiring connection specification ■Valve specification T0 T1 T2 T3 T4 T5 -S Single wiring: Wiring as single solenoid only. Note: This is not the same as packed wiring. : : : : : : 2-position, for single solenoid only 2-position, single solenoid specification 2-position, double solenoid specification 3-position, all port block 3-position, ABR connection 3-position, PAB connection -W Double wiring: Wiring is always for the double solenoid, regardless of the mounted valve type. Note: Valves of different sizes can not be combined together for mounting. Valve size Valve units Wiring specification Wiring connection specification Station Valve size Valve specification Double wiring type Note 2 Single wiring type Note 1 Manifold model 6 8 10 12 14 16 F10M FP Manual override Valve output type -F200 -F201 -S stn. 1 ・ ・ ・ stn.□ T0 T1 F10 Blank -R Note5 F15 Note6 -FJ -FJ5 -FJ6 -FM Blank -PP Note7 -NPM -NRM -NP6 -NR6 -NP8 -NR8 DC24V DC12V Note4 BPC (for block-off plate) F15M Note3 Voltage Mounting valve models Note3 6 8 Individual air supply and Wiring exhaust spacer specification FP -F200 -F201 -W stn. 1 ・ ・ ・ stn.□ F10 F15 T0 T1 T2 T3 T4 T5 Blank -R Note6 -FJ -FJ5 -FJ6 -FM Blank -PP Note7 Note8 -NPM -NRM -NP6 -NR6 -NP8 -NR8 DC24V DC12V Note4 BPC (for block-off plate) Notes:1. Wiring as single solenoid only. Note that this is not the same as packed wiring. The mounting valves are limited to single solenoid only (T0, T1 specifications). Therefore, even if the T1 specification valve is switched over to a double solenoid, no current will be applied to the B side solenoid. 2. Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. 3. Number of units in terms of the wiring connection specifications are, for single wiring 6∼16 (even numbers only), and for double wiring, 6 or 8. 4. Valve mounting location from the left, with solenoid on top, and A and B ports front. 5. The mounting valves are limited to T0, T1 specifications only (single solenoid specifications). In addition, even if the T1 specification valve is switched over to a double solenoid, no current will be applied to the B side solenoid. 6. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. 7. Always enter -PP. 8. Lead wire on solenoid B side (white) is not available for the valve specification T0. 540 Additional Parts Order Code for PC Board Manifold F Type Gasket (gasket and exhaust valve) F Z - GS1 GS1:Gasket Valve size 10:10mm width 15:15mm width BPC:Block-off plate Block-off plate (block-off plate, 2 mounting screws and housing) F BPC Valve size 10:10mm width 15:15mm width Connector-related order code FZ - Valve specification Blank: For T1, T2, T3, T4, T5 0: For T0 Connector specification P10 : For F10 series Connector lead wire for PC board manifold P15 : For F15 series Connector lead wire for PC board manifold Exhaust valve Red Common wire (+) Housing※ Black Side A (–) White Side B (–) ※: Use as a cover when the block-off plate is attached. Note: White lead wire is not available for FZ0-P□. Individual air supply and exhaust spacer F for non-plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws ) Z - Valve size 10:10mm width 15:15mm width Specification NPM NP6 NP8 NRM NR6 NR8 : : : : : : Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15) ※For details, see p.516. Manifold Order Code Example (8 units of F10 Series) Muffler KM - J F10M8FP-F201-W stn.1∼ 4 F10T0-FJ5-PP DC24V stn.5∼ 7 F10T2-FJ6-PP DC24V stn.8 F10BPC Note: This order code example has no relation to the illustration at upper right. Fitting size 6 : Outer diameter φ6 (for individual exhaust spacer) 8 : Outer diameter φ8 (for individual exhaust spacer) 10 : Outer diameter φ10 (for individual exhaust spacer) (Sales unit: Set of 10 mufflers) Precautions for Order Code ● Orders for valves only Use the code Valve size Valve specification Manual override - Valve output type - PP Voltage to order. If the lead wire for PC board is not necessary, enter -PN. ● Wiring connection specification -S (single wiring): Wiring as single solenoid only. -W (double wiring): Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. 541 SOLENOID VALVES F SERIES (Insert when using as a double solenoid) Note Split Manifold Non-Plug-in Type Order Code ■Manifold output specification With different size fitting block (base piping type) F10M 10mm width ■Pilot specification With single size fitting block (base piping type) ■Piping block specification Different size fitting block -JR : Different size fitting, right-side mounting -JL : Different size fitting, left-side mounting -JD : Different size fitting, both-sides mounting Fitting size (P and R ports) F10, F15 : φ8, φ10 F18 : φ12 only Blank Internal pilot manifold Effective area 5mm2 G F15M External pilot manifold 15mm width J Effective area 10mm2 F18M 18mm width Effective area 18mm2 Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 With female thread block (base piping type) L Output port fitting F10:φ4 orφ6 F15:φ6 orφ8 F18:φ8 orφ10 Female thread block -MR : Female thread, right-side mounting -ML : Female thread, left-side mounting -MD : Female thread, both-side mounting Female thread size (P and R ports) F10, F15 : Rc1/4 F18 : Rc3/8 With plate (direct piping type) M ■Valve specification Single size fitting block (F18 cannot be selected) -J5R : Single size fitting, right-side mounting -J5L : Single size fitting, left-side mounting -J5D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15 : φ8 -J6R : Single size fitting, right-side mounting -J6L : Single size fitting, left-side mounting -J6D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15 : φ10 Blank Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 T0 : 2-position, for single solenoid only T1 : 2-position, single solenoid specification T2 : 2-position, double solenoid specification T3 : 3-position, all port block T4 : 3-position, ABR connection T5 : 3-position, PAB connection ■Valve output type ■Wiring specification With plate Note3 (base piping type) S type plug connector Without connector -A1 With different size fitting block (direct piping type) ■Manifold fitting specification Manifold side output port single size fitting -PN With output port single size fitting block (direct piping type) Manifold side output port single size fitting -J5 S type plug connector S type plug connector Lead wire 300mm Lead wire 3000mm ■Operation method -J6 Output port fitting F10:φ4 F15:φ6 F18:φ8 Output port fitting F10:φ6 F15:φ8 F18:φ10 Blank Internal pilot type Note5 -FJ G External pilot type Note6 (for positive pressure) ※ No vacuum valve can be mounted. ■ Manual override Manual override Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 With female thread block (base piping type) -FJ5 -PS Output port fitting F10:φ4 F15:φ6 F18:φ8 With output port single size fitting block (direct piping type) Plus common prewiring connection S type plug connector Lead wire 300mm -PS3 Plus common prewiring connection S type plug connector Lead wire 3000mm -CPS -FM Blank Manual lever override (made to order) Note2 Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 ■Split Blank : -SP : -SR : -SA : Without split For P port Note 4 For R port Note 4 For both P and R ports Note 4 -CPS3 -FJ6 Output port fitting F10:φ6 F15:φ8 F18:φ10 ■Individual air supply and exhaust spacer Blank : Without spacer -NPM : Individual air supply spacer (with M5 female thread for F10) -NP6 : Individual air supply spacer (with φ6 fitting for F15) -NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) -NP0 : Individual air supply spacer (with φ10 fitting for F18) -NRM : Individual exhaust spacer (with M5 female thread for F10) -NR6 : Individual exhaust spacer (with φ6 fitting for F15) -NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) -NR0 : Individual exhaust spacer (with φ10 fitting for F18) For details, see p.516. -R Note: Valves of different sizes can not be combined together for mounting. Valve size Manifold output specification Valve units Pilot specification Piping block specification Station Valve size Valve specification Operation method Manual override Manifold model Base piping type F10M Base piping type single size fitting F15M F18M Direct piping type 2 ・ ・ ・ 20 J Blank M G L G Blank Blank Manifold fitting Wiring specifications specification Individual air supply and exhaust spacer Split Voltage Blank DC24V DC12V AC100V Mounting valve models Blank N Valve output type G Note7 -JR -JL -JD -MR -ML -MD -J5R -J6R Note7 -J5L Note7 -J6L Note7 -J5D Note7 -J6D Note7 stn. 1 ・ ・ ・ stn.□ -JR -JL -JD -MR -ML -MD -J5R Note7 -J6R Note7 -J5L Note7 -J6L Note7 -J5D Note7 -J6D Note7 stn. 1 ・ ・ ・ stn.□ -JR -JL -JD -MR -ML -MD -J5R Note7 -J6R Note7 -J5L Note7 -J6L Note7 -J5D Note7 -J6D Note7 stn. 1 ・ ・ ・ stn.□ Note1 F10 F15 T0 T1 T2 T3 T4 T5 Blank Note5 G Note6 Blank -R Note2 -A1 Note3 F18 -PN -PS -PS3 -CPS -CPS3 Blank -NPM -NP6 -NP8 -NP0 -NRM -NR6 -NR8 -NR0 Note1 F15 T0 T1 T2 T3 T4 T5 Blank Note5 G Note6 Blank -R Note2 -A1 Note3 F18 -PN -PS -PS3 -CPS -CPS3 Blank -J5 -J6 -NPM -NP6 -NP8 -NP0 -NRM -NR6 -NR8 -NR0 Note1 F15 T0 T1 T2 T3 T4 T5 Blank Note5 G Note6 Blank -R Note2 F18 BPN (for block-off plate) Blank -SP Note4 -SR Note4 DC24V DC12V AC100V -SA Note4 BPN (for block-off plate) F10 -SR Note4 -SA Note4 BPN (for block-off plate) F10 -SP Note4 -FJ -FJ5 -FJ6 -FM -PN -PS -PS3 -CPS -CPS3 Blank -NPM -NP6 -NP8 -NP0 -NRM -NR6 -NR8 -NR0 Blank -SP Note4 -SR Note4 DC24V DC12V AC100V -SA Note4 Notes: 1. Valve mounting location is from the left, with solenoid on top, and A and B ports front. 2. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. 3. When selecting J, M, or L (base piping type) for the manifold output specification, always enter -A1 (with plate) for the valve output type. 4. Splits can be installed only when piping blocks are mounted on both sides. In addition, only 1 piece split may be mounted in one manifold for -SA, or one each split for -SP and -SR, for a total of two locations. When in delivery, the designated splits are mounted between the designated station and the station to its immediate left (the next smaller stn. No.). 5. Cannot be mounted on the external pilot manifold. 6. Cannot be mounted on the internal pilot manifold. 7. F18 cannot be selected. 542 543 SOLENOID VALVES F SERIES ■Valve size Additional Parts Order Code for Split Manifold Non-Plug-in Type Manifold parts F Piping block assembly Z - F Valve size 10:10mm width 15:15mm width 18:18mm width Parts content GS2 : Gasket (gasket and exhaust valve) SP : Split (for P port) SR : Split (for R port) SA : Split (for both P and R ports) Z Piping specification PJ: Different size fitting piping block (For F18, single size fitting φ12) PJ5: Single size fitting piping block φ8 (For F18 cannot be selected) PJ6: Single size fitting piping block φ10 (For F18 cannot be selected) PM: Female thread piping block Valve size 10:10mm width 15:15mm width 18:18mm width Block-off plate (block-off plate, 2 mounting screws and plug ※) F ※: No plug is included in F18. BP N Valve size 10:10mm width 15:15mm width 18:18mm width Pilot specification Blank : Internal pilot G : External pilot For non-plug-in End blocks (one set of left and right) F Connector-related order code FZ ※For details, see p.513. Connector specification CP : Connector, lead wire length 300mm CP3 : Connector, lead wire length 3000mm CLN : Connector without lead wire (short bar, contacts included) PA : Plus common A type, lead wire length 300mm※ PA3 : Plus common A type, lead wire length 3000mm※ PB : Plus common B type, lead wire length 300mm※ PB3 : Plus common B type, lead wire length 3000mm※ PC : Plus common C type, lead wire length 300mm※ PC3 : Plus common C type, lead wire length 3000mm※ CC1.5 : Cabtire cable, length 1500mm Note ※ CC3 : Cabtire cable, length 3000mm Note ※ Note: Not available for T0. -E Valve size Pilot specification 10:10mm width Blank : Internal pilot※ 15:15mm width G : External pilot (only for F10 and F15) 18:18mm width ※: For F18, internal pilot and external pilot use are shareable. - Valve specification Blank: For T1, T2, T3, T4, T5 0: For T0 Z Independent air supply and exhaust spacer for non-plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws ) F Z - Valve size 10:10mm width 15:15mm width 18:18mm width ●Common connector assembly Specification NPM : NP6 : NP8 : NP0 : NRM : NR6 : NR8 : NR0 : Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15 and F18) Individual air supply spacer (with φ10 fitting for F18) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15 and F18) Individual exhaust spacer (with φ10 fitting for F18) ※For details, see p.516. A Type :FZ-PA□※ Red Common wire (+) Black A side (–) White B side (–) (Insert when using as double solenoid) Note Muffler B Type:FZ-PB□※ KM - J Red Common wire (+) Black A side (–) Note White B side (–) (Insert when using as double solenoid) C Type:FZ-PC□※ Red Black White Red ※: Lead wire length Blank: 300mm 3: 3000mm Fitting size 6 : Outer diameter φ6 (for individual exhaust spacer) 8 : Outer diameter φ8 (for individual exhaust spacer) 10 : Outer diameter φ10 (for F10, F15 and for individual exhaust spacer) 12 : Outer diameter φ12 (for F18) (Sales unit: Set of 10 mufflers) Common wire (+) A side (–) Note B side (–) (Insert when using as double solenoid) Common wire (+) Note: White lead wire is not available for FZ0-P□□. Connecting rod (F18 series only) F18 Z - Valve base assembly (valve base and gasket) F Z Valve size 10:10mm width 15:15mm width 18:18mm width Piping specification VJ : Different size fitting valve base VJ5 : Single size fitting valve base F10: φ4, F15: φ6, F18: φ8 VJ6 : Single size fitting valve base F10: φ6, F15: φ8, F18: φ10 VM : Female thread valve base VP : Valve base plate Pilot specification Blank: Internal pilot※ G : External pilot (only for F10 and F15) ※ For F18, internal pilot and external pilot use are shareable. 544 Additional unit number 01~20 (01~04 for RH) ※For reduction of units, consult us. Specification RV: For valve base RH: For piping and wiring base GS2:Gasket BPN:Block-off plate Plug Piping block assembly SP:Split for the P port Note SR:Split for the R port Note End block Exhaust valve Valve base assembly SOLENOID VALVES F SERIES Note: The F18 series split looks different in its appearance. ※The illustration shows the F10 series. Manifold Order Code Example (4 units of F10 Series) F10M4NL-J5R stn.1∼ 2 stn.3 stn.4 F10T0-A1-PS-J5 DC24V F10T2-A1-PS-J6 DC24V F10BPN-J6 Note: This order code example has no relation to the illustration above. Precautions for Order Code ●Orders for valves only Place orders from “Single Valve Unit Order Code” on p. 532. However, Blank, A2, F3, F4, F5, and F6 cannot be selected for the valve output type. And for the wiring specification, Blank, PL, and PL3 cannot be selected. In addition, for common terminal wiring connections, separately order the common connector assemblies listed on the previous page. 545 Split Manifold Plug-in Type Order Code ■Manifold output specification With different size fitting block (base piping type) ■Pilot specification With single size fitting block (base piping type) ■Wiring specification (wiring block) ■Wiring connection specification Flat cable connector (with socket and strain relief) Blank Internal pilot manifold ■Valve specification T0 T1 T2 T3 T4 T5 Blank Packed wiring: Wiring is made accordance with the mounted valve specifications. G External pilot manifold J L Output port fitting F10:φ4 or φ6 F15:φ6 or φ8 F18:φ8 orφ10 With female thread block (base piping type) With plate (direct piping type) M -F100:10-pin -F101:10-pin -F200:20-pin -F201:20-pin -F260:26-pin For details, see p. 560. Terminal block (19 terminals M3 screws) D sub connector ■Piping block specification Different size fitting block -JR : Different size fitting, right-side mounting -JL : Different size fitting, left-side mounting -JD : Different size fitting, both-side mounting Fitting size (P and R ports) F10, F15 : φ8, φ10 F18 : φ12 only Blank F10M 10mm width Effective area 5mm2 F15M ■Manifold fitting specification With plate Note 4 (base piping type) Manifold side Manifold side output port single size fitting output port single size fitting -A1 ■Operation method -J5 With different size fitting block (direct piping type) Blank With output port single size fitting block (direct piping type) Internal pilot type Note8 -J6 Output port fitting F10:φ4 F15:φ6 F18:φ8 Output port fitting F10:φ6 F15:φ8 F18:φ10 G ■Wiring position (wiring block) External pilot type Note9 (for positive pressure) ※ No vacuum valve can be mounted. -FJ ■Manual override -D25□ Single size fitting block (F18 cannot be selected) -J5R : Single size fitting, right-side mounting -J5L : Single size fitting, left-side mounting -J5D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15 : φ8 -J6R : Single size fitting, right-side mounting -J6L : Single size fitting, left-side mounting -J6D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15 : φ10 ■Valve size Double wiring: Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. Blank : Left-side mounting -R : Right-side mounting Female thread block -MR : Female thread, right-side mounting -ML : Female thread, left-side mounting -MD : Female thread, both-side mounting Female thread size (P and R ports) F10, F15 : Rc1/4 F18 : Rc3/8 Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 2-position, for single solenoid only 2-position, single solenoid specification 2-position, double solenoid specification 3-position, all port block 3-position, ABR connection 3-position, PAB connection -W -F□ Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 : : : : : : ■Valve output type -T200 Manual override (Fitting stand M2.6 Also can provide screws) the terminal block -D250:25-pin with cover.Note10 -D251:25-pin For details, see p. 560. ■Individual air supply and exhaust spacer -FJ5 Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 Output port fitting F10:φ4 F15:φ6 F18:φ8 With female thread block (direct piping type) With output port single size fitting block (direct piping type) Blank : Without spacer -PPM : Individual air supply spacer (with M5 female thread for F10) -PP6 : Individual air supply spacer (with φ6 fitting for F15) -PP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) -PP0 : Individual air supply spacer (with φ10 fitting for F18) -PRM : Individual exhaust spacer (with M5 female thread for F10) -PR6 : Individual exhaust spacer (with φ6 fitting for F15) -PR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) -PR0 : Individual exhaust spacer (with φ10 fitting for F18) For details, see p.516. Blank -FM Manual lever override (made to order) Note6 -FJ6 Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 Output port fitting F10:φ6 F15:φ8 F18:φ10 ■Split Blank -SP -SR -SA : : : : -R Without split For P port Note 7 For R port Note7 For both P and R ports Note7 15mm width F18M 18mm width Effective area 18mm2 Note: Valves of different sizes can not be combined together for mounting. Valve size Valve units Manifold output specification Pilot specification Piping block specification Wiring specification Wiring connection specification Wiring position Voltage Station Valve size Valve specification Operation method Manifold model Base piping type Base piping type single size fitting Direct piping type F10M F15M F18M 2 ・ ・ ・ □ J Blank M G Blank P L G Note1 Blank Blank G Note11 Valve output Manifold fitting specification type Individual air supply and exhaust spacer Split Voltage Mounting valve models -JR -JL -JD -MR -ML -MD -J5R -J6R Note11 -J5L Note11 -J6L Note11 -J5D Note11 -J6D Note11 -F100 -D250 -F101 -D251 -F200 -T200 -F201 -F260 -JR -JL -JD -MR -ML -MD -J5R Note11 -J6R Note11 -J5L Note11 -J6L Note11 -J5D Note11 -J6D Note11 -F100 -D250 -F101 -D251 -F200 -T200 -F201 -F260 -JR -JL -JD -MR -ML -MD -J5R Note11 -J6R Note11 -J5L Note11 -J6L Note11 -J5D Note11 -J6D Note11 -F100 -D250 -F101 -D251 -F200 -T200 -F201 -F260 Blank Blank -W -R DC24V DC12V Note2 AC100V stn. 1 ・ ・ ・ stn.□ F10 F15 T0 T1 T2 Blank Blank -W -R DC24V DC12V Note2 AC100V stn. 1 ・ ・ ・ stn.□ Blank Blank -W -R stn. 1 ・ ・ ・ stn.□ Note3 Notes: 3. 4. 5. 6. 7. 8. 9. 10. 11. Blank Blank Note8 G Note9 Blank -R Note6 -A1 -PPM -PP6 -PP8 -PP0 Note4 -PRM -PR6 -PR8 -PR0 F10 F15 T0 T1 T2 T3 T4 T5 Blank Blank Note8 G Note9 Blank -R Note6 -A1 Note4 F10 F15 T0 T1 T2 T3 T4 T5 Blank Note8 G Note9 -J5 -J6 F18 BPP (for block-off plate) -PPM -PP6 -PP8 -PP0 -PRM -PR6 -PR8 -PR0 -R Note6 F18 BPP (for block-off plate) Note5 -SP Note7 -SR Note7 DC24V DC12V Note2 AC100V Blank -SP Note7 -SR Note7 DC24V DC12V Note2 AC100V -SA Note7 Note5 Blank Blank -SA Note7 BPP (for block-off plate) Note5 Note3 DC24V DC12V Note2 AC100V T3 T4 T5 F18 Note3 Notes: 1. For the maximum number of units, see the table for the maximum number of valve units, by wiring specification, on p. 548. 2. AC100V is available only for the wiring specifications -D250, -D251 (D sub connector) and -T200 (terminal block). 546 Manual override -FJ -FJ5 -FJ6 -FM Blank -PPM -PP6 -PP8 -PP0 -PRM -PR6 -PR8 -PR0 Blank -SP Note7 -SR Note7 DC24V DC12V Note2 AC100V -SA Note7 Valve mounting location is from the left, with the solenoid on top, and A and B port side in front. When selecting J, M, or L (base piping type) for the manifold output specification, always enter -A1 (with plate) for the valve output type. Be aware that the block-off plate wiring is always double wiring (allocated 2 control pins at 1 stn.) regardless of the wiring connection specification. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. Splits can be installed only when piping blocks are mounted on both sides. In addition, only 1 piece split may be mounted in one manifold for -SA, or one each split for -SP and -SR, for a total of two locations. When in delivery, the designated splits are mounted between the designated station and the station to its immediate left (the next smaller stn. No.). Cannot be mounted on the external pilot manifold. Cannot be mounted on the internal pilot manifold. The terminal block with cover (code: append -139W to the end of the manifold code) can also be provided as a made to order item. For details, contact us. F18 cannot be selected. 547 SOLENOID VALVES F SERIES Effective area 10mm2 Additional Parts Order Code for Split Manifold Plug-in Type Manifold parts F Wiring block assembly (one set) Z - F Valve size 10:10mm width 15:15mm width 18:18mm width Parts content GS2 : Gasket (gasket and exhaust valve) SP : Split (for P port) SR : Split (for R port) SA : Split (for both P and R ports) ※ For F18, internal pilot and external pilot use are shareable. For plug-in Valve base assembly (valve base, gasket, lead wire and plug-in connector) F Z - Valve size 10:10mm width 15:15mm width 18:18mm width F Z - Valve size 10:10mm width 15:15mm width 18:18mm width Piping specification VJ : Different size fitting valve base VJ5 : Single size fitting valve base F10:φ4, F15: φ6, F18: φ8 VJ6 : Single size fitting valve base F10: φ6, F15,φ8, F18: φ10 VM : Female thread valve base VP : Valve base plate Specification PPM PP6 PP8 PP0 PRM PR6 PR8 PR0 ※For details, see p. 516. Fitting size 6 :Outer diameter φ6 (for individual exhaust spacer) 8 :Outer diameter φ8 (for individual exhaust spacer) 10 :Outer diameter φ10 (for F10, F15 and for individual exhaust spacer) 12 :Outer diameter φ12 (for F18) (Sales unit: Set of 10 mufflers) Piping specification PJ : Different size fitting piping blocks (for F10 and F15) PJ5 : Single size fitting piping block φ8 (Not available for F18) PJ6 : Single size fitting piping blockφ10 (Not available for F18) PM : Female thread piping block (for F10, F15) PJP : Fitting piping block (for F18 only) PMP : Female thread piping block (for F18 only) Connecting rod (F18 series only) F18 Z - Additional unit number 01~20 (01~04 for RH) ※Example: To add two valve units, enter -02. ※For reduction of units, consult us. Pilot specification Blank : Internal pilot G : External pilot End blocks (one set of left and right) Z Specification RV: For valve base RH: For piping and wiring base - End block specification Valve size E :For F10, F15 10:10mm width EP:For F18 15:15mm width 18:18mm width Pilot specification Blank : Internal pilot※ G : External pilot (only for F10 and F15) ※: For F18, internal pilot and external pilot use are shareable. 548 Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15 and F18) Individual air supply spacer (withφ10 fitting for F18) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15 and F18) Individual exhaust spacer (with φ10 fitting for F18) KM - J - Valve size 10:10mm width 15:15mm width 18:18mm width F : : : : : : : : Muffler Piping block assembly Z for plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws ) - ※: For F18, internal pilot and external pilot use are shareable. F Piping specification F100 :Flat cable connector (DC specification) F101 :Flat cable connector (DC specification) F200 :Flat cable connector (DC specification) F201 :Flat cable connector (DC specification) F260 :Flat cable connector (DC specification) D250 :D sub connector D251 :D sub connector T200L :Terminal block for left-side mounting T200R :Terminal block for right-side mounting Individual air supply and exhaust spacer Wiring specification D: For D sub connector F: For flat cable connector, terminal block Pilot specification Blank : Internal pilot※ G : External pilot (only for F10 and F15) Voltage (Not required for T200) DC24 DC12 AC100(for D250,D251only) Pilot specification Blank : Internal pilot※ G : External pilot (Only for F10 and F15) BP P Valve size 10:10mm width 15:15mm width 18:18mm width - Valve size 10:10mm width 15:15mm width 18:18mm width Block-off plate (block-off plate, 2 mounting screws and plug) F Z ■Table for maximum number of valve units, by wiring specification Maximum number of units Wiring connection specification Wiring specification Max. control pts. F100 Flat cable (10P) 8 points F101 Flat cable (10P) 8 points F200 Flat cable (20P) 16 points F201 Flat cable (20P) 16 points F260 Flat cable (26P) 20 points D250 D sub connector (25P) 16 points D251 D sub connector (25P) 20 points T200 Terminal block (19 terminals) 18 points Packed wiring (Blank) Varies depending on the mounted number of single solenoids, double solenoids, and block-off plates. The number of controlled solenoids should be designated at the maximum number of control points or less. Double wiring (-W) 4 units 4 units 8 units 8 units 10 units 8 units 10 units 9 units GS2:Gasket Plug BPP:Block-off plate SP:Split for the P port SR:Split for the R port End block Piping block assembly Plug-in connector Valve base assembly Wiring block assembly Note: The F18 series split looks different in its appearance. ※The illustration shows the F10 series. SOLENOID VALVES F SERIES Exhaust valve Manifold Order Code Example (12 units of F10 Series) F10M12PL-J5R-F201 DC24V stn.1∼ 8 F10T0-A1-J5 DC24V stn.9∼ 11 F10T2-A1-J6 DC24V stn.12 F10BPP-J6 Note: This order code example has no relationship to the illustration above. Precautions for Order Code ●Orders for valves only Place orders from “Single Valve Unit Order Code” on p. 532. However, Blank, A2, F3, F4, F5, and F6 cannot be selected for the valve output type. For the wiring specification, Blank is the only selection. ●Wiring connection specification Blank (packed wiring) : Wiring is made accordance with the mounted valve specifications. -W (double wiring) : Wiring is always for the double solenoid, regardless of the mounted valve specifications. 549 ■Manifold output specification With different size fitting block (base piping type) ■Pilot specification With single size fitting block (base piping type) ※For the order code for Omron CompoBus/D, see p. 554. ■Transmission block specification ■Wiring connection specification ※ These are the serial transmission block specifications compatible with each system. Blank Internal pilot manifold Blank Packed wiring: Wiring is made accordance with the mounted valve specifications. F10, F15 series For details, see p. 525 ∼ 527. G External pilot manifold J T0 T1 T2 T3 T4 T5 : : : : : : ■Valve output type 2-position, for single solenoid only 2-position, single solenoid specification 2-position, double solenoid specification 3-position, all port block 3-position, ABR connection 3-position, PAB connection Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 Output port fitting F10:φ4 or φ6 F15:φ6 or φ8 F18:φ8 or φ10 With female thread block (base piping type) With plate (direct piping type) ●Delivered with mounted on the DIN rail. ■Piping block specification Different size fitting block -JR : Different size fitting, right-side mounting -JL : Different size fitting, left-side mounting -JD : Different size fitting, both-side mounting Fitting size (P and R ports) F10, F15: φ8,φ10 F18: φ12 only Blank Female thread block -MR : Female thread, right-side mounting -ML : Female thread, left-side mounting -MD Female thread, both-side mounting Female thread size (P and R ports) F10, F15: Rc1/4 F18: Rc3/8 Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 Single size fitting block (F18 cannot be selected) -J5R : Single size fitting, right-side mounting -J5L : Single size fitting, left-side mounting -J5D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15: φ8 -J6R : Single size fitting, right-side mounting -J6L : Single size fitting, left-side mounting -J6D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15: φ10 ■Valve size F10M 10mm width Effective area 5mm2 F15M 15mm width Effective area 10mm2 F18 series Manifold side output port single size fitting -A1 ■Operation method Double wiring: Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. ■ Manifold fitting specification With plate Note3 (base piping type) -W L M ■Valve specification -J5 With different size fitting block (direct piping type) Blank Manifold side output port single size fitting With output port single size fitting block (direct piping type) Internal pilot typeNote7 -J6 Output port fitting F10:φ4 F15:φ6 F18:φ8 Output port fitting F10:φ6 F15:φ8 F18:φ10 G For details, see p. 525 ∼ 527. ■Wiring position (wiring block) External pilot typeNote8 (for positive pressure) ※ No vacuum valve can be mounted. Blank : Left side mounting -R : Right side mounting -01 : For UNI-WIRE System (16-point output) -02 : For UNI-WIRE System (8-point output) -11 : For Mitsubishi Electric MELSECNET/MINI-S3 -21 : For Omron SYSBUS Wire System -31 : For Omron B7A Link Terminal (Standard) -32 : For Omron B7A Link Terminal (High speed) -41 : For Koyo Electronics Industries SA Bus (16-point output) -42 : For Koyo Electronics Industries SA Bus (8-point output) -51 : For Sunx S-LINK (16-point output) -52 : For Sunx S-LINK (8-point output) -61 : For Mitsubishi Electric MELSEC I/O LINK -71 : For Fuji Electric T Link Mini -81 : For Keyence KZ-R -A1 : For Omron CompoBus/S (16-point output) -A2 : For Omron CompoBus/S (8-point output) -B1 : For Mitsubishi Electric CC-Link -FJ ■Manual override Manual override ■Individual air supply and exhaust spacer -FJ5 Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 With female thread block (direct piping type) Output port fitting F10:φ4 F15:φ6 F18:φ8 With output port single size fitting block (direct piping type) Blank : Without spacer -PPM : Individual air supply spacer (with M5 female thread for F10) -PP6 : Individual air supply spacer (with φ6 fitting for F15) -PP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) -PP0 : Individual air supply spacer (with φ10 fitting for F18) -PRM : Individual exhaust spacer (with M5 female thread for F10) -PR6 : Individual exhaust spacer (with φ6 fitting for F15) -PR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) -PR0 : Individual exhaust spacer (with φ10 fitting for F18) For details, see p. 516. Blank -FM Manual lever override (made to order) Note5 -FJ6 Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 Output port fitting F10:φ6 F15:φ8 F18:φ10 ■Split Blank : -SP : -SR : -SA : -R Without split For P port Note6 For R port Note 6 For both P and R ports Note6 F18M 18mm width Effective area 18mm2 Note: Valves of different sizes can not be combined together for mounting. Valve size Valve units Manifold output specification Pilot specification Piping block specification Transmission block specification Wiring connection specification Wiring position Station Valve size Valve specification Operation method Manifold model Base piping type Base piping type single size fitting F10M F15M F18M 2 ・ ・ ・ □ J Blank M G Blank S L G Note1 Direct piping type Blank Blank G Valve output Manifold fitting specification type Individual air supply and exhaust spacer Split Voltage Mounting valve models Note9 -JR -JL -JD -MR -ML -MD -J5R -J6R Note9 -J5L Note9 -J6L Note9 -J5D Note9 -J6D Note9 -01 -02 -11 -21 -31 -32 -41 -42 -51 -52 -61 -71 -81 -A1 -A2 -B1 -JR -JL -JD -MR -ML -MD -J5R Note9 -J6R Note9 -J5L Note9 -J6L Note9 -J5D Note9 -J6D Note9 -01 -02 -11 -21 -31 -32 -41 -42 -51 -52 -61 -71 -81 -A1 -A2 -B1 -JR -JL -JD -MR -ML -MD -J5R Note9 -J6R Note9 -J5L Note9 -J6L Note9 -J5D Note9 -J6D Note9 -01 -02 -11 -21 -31 -32 -41 -42 -51 -52 -61 -71 -81 -A1 -A2 -B1 Blank Blank -W -R stn. 1 ・ ・ ・ stn.□ F10 F15 T0 T1 T2 Blank Blank -W -R stn. 1 ・ ・ ・ stn.□ Blank Blank -W -R Note2 Blank BlankNote7 G Note8 Blank -R Note5 -A1 -PPM -PP6 -PP8 -PP0 Note3 -PRM -PR6 -PR8 -PR0 F10 F15 T0 T1 T2 T3 T4 T5 Blank BlankNote7 G Note8 Blank -R Note5 -A1 Note3 -J5 -J6 F18 -PPM -PP6 -PP8 -PP0 -PRM -PR6 -PR8 -PR0 F15 T0 T1 T2 T3 T4 T5 BlankNote7 G Note8 Blank -R Note5 F18 BPP (for block-off plate) Note4 -SP Note6 DC24V -SR Note6 Blank -SP Note6 DC24V -SR Note6 -SA Note6 BPP (for block-off plate) Note4 F10 Blank -SA Note6 BPP (for block-off plate) Note4 Note2 stn. 1 ・ ・ ・ stn.□ T3 T4 T5 F18 Note2 Note: 1. For the maximum number of units, see the table for the maximum number of valve units, by serial transmission block specification, on p.552. 550 Manual override -FJ -FJ5 -FJ6 -FM Blank -PPM -PP6 -PP8 -PP0 -PRM -PR6 -PR8 -PR0 Blank -SP Note6 DC24V -SR Note6 -SA Note6 Notes: 2. Valve mounting location is from the left, with solenoid on top, and A and B ports side in front. 3. When selecting J, M, or L (base piping type) for the manifold output specifications, always enter -A1 (with plate) for the valve output type. 4. Be aware that the block-off plate wiring is always double wiring (allocated 2 control pins at 1 stn.) regardless of the wiring connection specification. 5. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. 6. Splits can be installed only when piping blocks are mounted on both sides. In addition, only 1 piece split may be mounted in one manifold for -SA, or one each split for -SP and -SR, for a total of two locations. When in delivery, the designated splits are mounted between the designated station and the station to its immediate left (the next smaller stn. No.). 7. Cannot be mounted on the external pilot manifold. 8. Cannot be mounted on the internal pilot manifold. 9. F18 cannot be selected. 551 SOLENOID VALVES F SERIES Serial Transmission Compatible Manifold Order Code Additional Parts Order Code for Serial Transmission Compatible Manifold Manifold parts F Individual air supply and exhaust spacer Z - F Valve size 10:10mm width 15:15mm width 18:18mm width Parts content GS2 : Gasket (gasket and exhaust valve) SP : Split (for P port) Only for F10, SR : Split (for R port) F15 series SA : Split (for both P and R ports) Z - Valve size 10:10mm width 15:15mm width 18:18mm width Block-off plate (block-off plate, 2 mounting screws and plug) F BPP Specification PPM PP6 PP8 PP0 PRM PR6 PR8 PR0 : : : : : : : : Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15 and F18) Individual air supply spacer (withφ10 fitting for F18) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15 and F18) Individual exhaust spacer (with φ10 fitting for F18) ※For details, see p. 516. Serial transmission block (single unit) Valve size 10:10mm width 15:15mm width 18:18mm width YS2 Valve base assembly※ (valve base, gasket, lead wire and plug-in connector) F for plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws ) Z - Valve size 10:10mm width 15:15mm width -F Piping specification VJ : Different size fitting valve base VJ5 : Single size fitting valve base F10:φ4, F15:φ6 VJ6 : Single size fitting valve base F10:φ6, F15,φ8 VM : Female thread valve base VP : Valve base plate Pilot specification Blank : Internal pilot G : External pilot Wiring position L: For stand-alone type, left-side mounting (for F10, F15 series)※ R: For stand-alone type, right-side mounting (for F10, F15 series)※ S: For monoblock type, left-side mounting (for F18 series) T: For monoblock type, right-side mounting (for F18 series) ※: DIN rail (length 75mm) also provided. Transmission block specification 01 : For UNI-WIRE System (16-point output) 02 : For UNI-WIRE System (8-point output) 11 : For Mitsubishi Electric MELSECNET/ MINI-S3 21 : For Omron SYSBUS Wire System 31 : For Omron B7A Link Terminal (Standard) 32 : For Omron B7A Link Terminal (High Speed) 41 : For Koyo Electronics Industries SA Bus (16-point output) 42 : For Koyo Electronics Industries SA Bus (8-point output) 51 : For Sunx S-LINK (16-point output) 52 : For Sunx S-LINK (8-point output) 61 : For Mitsubishi Electric MELSEC I/O LINK 71 : For Fuji Electric T Link Mini 81 : For Keyence KZ-R A1 : For Omron CompoBus/S (16-point output) A2 : For Omron CompoBus/S (8-point output) B1 : For Mitsubishi Electric CC-Link ※: Except the F18 series Piping block assembly※ F Z - Muffler Cable for S-LINK YS151-K B 2 KM - J (Cable length 2000mm) Valve size 10:10mm width 15:15mm width Piping specification PJ : Different size fitting piping block (for F10 and F15) PJ5 : Single size fitting piping block φ8 (not available for F18) PJ6 : Single size fitting piping block φ10 (not available for F18) PM : Female thread piping block (for F10 and F15) ※: Except the F18 series Pilot specification Blank : Internal pilot G : External pilot Fitting size 6 : Outer diameter φ6 (for individual exhaust spacer) 8 : Outer diameter φ8 (for individual exhaust spacer) 10 : Outer diameter φ10 (for F10, F15 and for individual exhaust spacer) 12 : Outer diameter φ12 (for F18) (Sales unit: Set of 10 mufflers) ■ Table for maximum number of valve units, by transmission block specification End blocks ※ F (one set of left and right) Z - E Wiring specifications Valve size Pilot specification 10:10mm width Blank : Internal pilot 15:15mm width G : External pilot ※: Except the F18 series ※ Wiring block assembly F Z - F201 - DC24 Valve size Pilot specification 10:10mm width Blank : Internal pilot 15:15mm width G : External pilot ※: Except the F18 series Maximum number of units Wiring connection specification 16 points 8 units -02 : For UNI-WIRE System (8-point output) 8 points 4 units -11 : For Mitsubishi Electric MELSECNET/MINI-S3 16 points -21 : For Omron SYSBUS Wire System 16 points -31 : For Omron B7A Link Terminal (Standard) 16 points -32 : For Omron B7A Link Terminal (High Speed) 16 points -41 : For Koyo Electronics Industries SA Bus (16-point output) 16 points -42 : For Koyo Electronics Industries SA Bus (8-point output) 8 points -51 : For Sunx S-LINK (16-point output) 16 points -52 : For Sunx S-LINK (8-point output) 8 points 8 units Varies depending on the mounted number of single solenoids, double solenoids, and block-off plates. The number of controlled solenoids should be designated at the maximum number of control points or less. 8 units 8 units 8 units 8 units 4 units 8 units 4 units -61 : For Mitsubishi Electric MELSEC I/O LINK 16 points -71 : For Fuji Electric T Link Mini 16 points -81 : For Keyence KZ-R 16 points 8 units -A1: For Omron CompoBus/S (16-point output) 16 points 8 units -A2: For Omron CompoBus/S (8-point output) 8 points 4 units 16 points 8 units -B1: For Mitsubishi Electric CC-Link 552 Max. control pts. Packed wiring (Blank) Double wiring (-W) -01 : For UNI-WIRE System (16-point output) 8 units 8 units GS2:Gasket BPP:Block-off plate Plug SP:Split for the P port SR:Split for the R port End block Piping block assembly Plug-in connector Valve base assembly Exhaust valve Wiring block assembly SOLENOID VALVES F SERIES ※The illustration shows the F10 series. Manifold Order Code Example (8 units of F10 Series) F10M8SL-J5R-21-W stn.1∼ 5 stn.6∼ 7 stn.8 F10T0-A1-J5 DC24V F10T2-A1-J6 DC24V F10BPP-J6 Note: This order code example has no relationship to the illustration above. Precautions for Order Code ● Order for valves only Use the code Valve size Valve specification Operation method Manual override Valve output type Voltage to order. ● Wiring connection specification Blank (packed wiring) : Wiring is made accordance with the mounted valve specifications. -W (double wiring) : Wiring is always for the double solenoid, regardless of the mounted valve specifications. Caution: Be aware that the block-off plate wiring connections are always double wiring (allocated 2 control points to 1 unit) regardless of the wiring connection specification. 553 Serial Transmission Compatible Manifold for OMRON Corporation CompoBus/D Order Code With different size fitting block (base piping type) ■Pilot specification With single size fitting block (base piping type) ■Transmission block specification ■Wiring connection specification -91: For Omron CompoBus/D Note Note: The transmission block is for leftside mounting only. Blank Internal pilot manifold F10, F15 series G ■Valve specification T0 T1 T2 T3 T4 T5 Blank Packed wiring: Wiring is made accordance with the mounted valve specifications. External pilot manifold J Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 With female thread block (base piping type) 2-position, for single solenoid only 2-position, single solenoid specification 2-position, double solenoid specification 3-position, all port block 3-position, ABR connection 3-position, PAB connection Output port fitting F10:φ4 or φ6 F15:φ6 or φ8 F18:φ8 or φ10 ■Piping block specification Different size fitting block -JR : Different size fitting, right-side mounting -JL : Different size fitting, left-side mounting -JD : Different size fitting, both-side mounting Fitting size (P and R ports) F10, F15: φ8, φ10 F18: φ12 only With plate (direct piping type) Blank ●Delivered with mounted on the DIN rail. Double wiring: Wiring is always for the double solenoid, regardless of the specifications of the mounted valve. F10M 10mm width Effective area 5mm2 F15M 15mm width Effective area 10mm2 With output port single size fitting block (direct piping type) Internal pilot type Note7 F18 series Manifold side output port single size fitting -J5 With different size fitting block (direct piping type) Blank -J6 Output port fitting F10:φ4 F15:φ6 F18:φ8 Output port fitting F10:φ6 F15:φ8 F18:φ10 G ■Individual air supply and exhaust spacer External pilot type Note8 (for positive pressure) ※ No vacuum valve can be mounted. -FJ ■Manual override Manual override Blank : Without spacer -PPM : Individual air supply spacer (with M5 female thread for F10) -PP6 : Individual air supply spacer (with φ6 fitting for F15) -PP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) -PP0 : Individual air supply spacer (with φ10 fitting for F18) -PRM : Individual exhaust spacer (with M5 female thread for F10) -PR6 : Individual exhaust spacer (with φ6 fitting for F15) -PR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) -PR0 : Individual exhaust spacer (with φ10 fitting for F18) For details, see p.516. -FJ5 Output port fitting F10:φ4 ,φ6 F15:φ6 ,φ8 F18:φ8 ,φ10 Output port fitting F10:φ4 F15:φ6 F18:φ8 With female thread block (direct piping type) With output port single size fitting block (direct piping type) Blank Single size fitting block (F18 cannot be selected) -J5R : Single size fitting, right-side mounting -J5L : Single size fitting, left-side mounting -J5D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15: φ8 -J6R : Single size fitting, right-side mounting -J6L : Single size fitting, left-side mounting -J6D : Single size fitting, both-side mounting Fitting size (P and R ports) F10 and F15: φ10 ■Valve size Manifold side output port single size fitting -A1 ■Operation method Female thread block -MR : Female thread, right-side mounting -ML : Female thread, left-side mounting -MD Female thread, both-side mounting Female thread size (P and R ports) F10, F15: Rc1/4 F18: Rc3/8 Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 ■Manifold fitting specification With plate Note3 (base piping type) -W L M : : : : : : ■Valve output type -FM Manual lever override (made to order) Note5 -FJ6 Output port female thread F10:M5×0.8 F15:Rc1/8 F18:Rc1/4 Output port fitting F10:φ6 F15:φ8 F18:φ10 ■Split Blank : -SP : -SR : -SA : -R Without split For P port Note6 For R port Note6 For both P and R ports Note6 F18M 18mm width Effective area 18mm2 Note: Valves of different sizes can not be combined together for mounting. Valve size Valve units Manifold output specification Pilot specification Piping block specification Transmission block specification Wiring connection specification Station Valve size Valve specification Operation method Manifold model Base piping type Base piping type single size fitting Direct piping type F10M F15M F18M 2 ・ ・ ・ □ J Blank M G Blank S L G Note1 Blank Blank G Valve output Manifold fitting specification type Individual air supply and exhaust spacer Split Voltage Mounting valve models Note9 -JR -JL -JD -MR -ML -MD -J5R -J6R Note9 -J5L Note9 -J6L Note9 -J5D Note9 -J6D Note9 -JR -JL -JD -MR -ML -MD -J5R Note9 -J6R Note9 -J5L Note9 -J6L Note9 -J5D Note9 -J6D Note9 -JR -JL -JD -MR -ML -MD -J5R Note9 -J6R Note9 -J5L Note9 -J6L Note9 -J5D Note9 -J6D Note9 Note: 1. For the maximum number of units, see the table for maximum number of valve units on p. 556. 554 Manual override Blank -91 -W stn. 1 ・ ・ ・ stn.□ F10 F15 T0 T1 T2 Blank -91 -W Blank -91 -W Note2 G Note8 Blank -R Note5 -A1 -PPM -PP6 -PP8 -PP0 Note3 -PRM -PR6 -PR8 -PR0 F10 F15 T0 T1 T2 T3 T4 T5 Blank Blank Note7 G Note8 Blank -R Note5 -A1 Note3 -J5 -J6 F18 -PPM -PP6 -PP8 -PP0 -PRM -PR6 -PR8 -PR0 F15 T0 T1 T2 T3 T4 T5 Blank Note7 G Note8 Blank -R Note5 F18 BPP (for block-off plate) Note4 -SP Note6 DC24V -SR Note6 Blank -SP Note6 DC24V -SR Note6 -SA Note6 BPP (for block-off plate) Note4 F10 Blank -SA Note6 BPP (for block-off plate) Note4 Note2 stn. 1 ・ ・ ・ stn.□ Blank Blank Note7 F18 Note2 stn. 1 ・ ・ ・ stn.□ T3 T4 T5 -FJ -FJ5 -FJ6 -FM Blank -PPM -PP6 -PP8 -PP0 -PRM -PR6 -PR8 -PR0 Blank -SP Note6 DC24V -SR Note6 -SA Note6 Notes: 2. 3. 4. 5. 6. Valve mounting location is from the left, with solenoid on top, and A and B ports side in front. When selecting J, M, or L (base piping type) for the manifold output specification, always enter -A1 (with plate) for the valve output type. Be aware that the block-off plate wiring is always double wiring (allocated 2 control pins to 1 unit) regardless of the wiring connection specifications. The manual lever override is made to order. Contact us for the delivery. When the valve specifications are T1 or T2, the manual lever override is placed on the A side only. Splits can be mounted only when piping blocks are mounted on both sides. In addition, 1 piece split may be mounted in one manifold for -SA, or one each split for -SP and -SR, for a total of two locations. When in delivery, the designated splits are mounted between the designated station and the station to its immediate left (the next smaller stn. No.). 7. Cannot be mounted on the external pilot manifold. 8. Cannot be mounted on the internal pilot manifold. 9. F18 cannot be selected. 555 SOLENOID VALVES F SERIES ■Manifold output specification Additional Parts Order Code for Serial Transmission Compatible Manifold Individual air supply and exhaust spacer Manifold parts F Z - Valve size 10:10mm width 15:15mm width 18:18mm width F Parts content GS2 : Gasket (gasket and exhaust valve) SP : Split (for P port) SR : Split (for R port) SA : Split (for both P and R ports) F Z Individual air supply spacer (with M5 female thread for F10) Individual air supply spacer (with φ6 fitting for F15) Individual air supply spacer (with φ8 fitting for F15 and F18) Individual air supply spacer (with φ10 fitting for F18) Individual exhaust spacer (with M5 female thread for F10) Individual exhaust spacer (with φ6 fitting for F15) Individual exhaust spacer (with φ8 fitting for F15 and F18) Individual exhaust spacer (with φ10 fitting for F18) Serial transmission block (single unit) Valve size 10:10mm width 15:15mm width 18:18mm width F Specification PPM : PP6 : PP8 : PP0 : PRM : PR6 : PR8 : PR0 : ※For details, see p. 516. BPP Valve base Z - Valve size 10:10mm width 15:15mm width 18:18mm width Block-off plate (block-off Plate, 2 mounting screws and plug) for plug-in type, gasket, ( Spacer exhaust valve and 2 mounting screws) YS3 91 Transmission block assembly (valve base, gasket, lead wire and plug-in connector) specification 91:For Omron CompoBus/D - Valve size 10:10mm width 15:15mm width 18:18mm width Pilot specification Blank : Internal pilot G : External pilot -F Piping specification VJ : Different size fitting valve base VJ5 : Single size fitting valve base F10: φ4, F15: φ6, F18: φ8 VJ6 : Single size fitting valve base F10: φ6, F15: φ8, F18: φ10 VM : Female thread valve base VP : Valve base plate Muffler KM - J Fitting size 6 : Outer diameter φ6 (for individual exhaust spacer) 8 : Outer diameter φ8 (for individual exhaust spacer) 10 : Outer diameter φ10 (for F10, F15 and for individual exhaust spacer) 12 : Outer diameter φ12 (for F18) (Sales unit: Set of 10 mufflers) GS2:Gasket Piping block assembly F Z BPP:Block-off plate Plug - Valve size 10:10mm width 15:15mm width 18:18mm width Piping specification PJ : Different size fitting piping block (for F10, F15) PJ5 : Single size fitting piping block φ8 (Not available for F18) PJ6 : Single size fitting piping block φ10 (Not available for F18) PM : Female thread piping block (for F10, F15) SP:Split for the P port SR:Split for the R port End block Pilot specification Blank: Internal pilot G : External pilot End blocks (one set of left and right) F Z Piping block assembly - E Plug-in connector Valve base assembly ※The illustration Exhaust valve shows the F10 series. Valve size Pilot specification 10:10mm width Blank: Internal pilot 15:15mm width G : External pilot 18:18mm width Wiring block assembly ■ Table for maximum number of valve units Maximum number of units Wiring block assembly Wiring connection specification Wiring specification F Z Max. control pts. Packed wiring (Blank) Double wiring (-W) - F201 - DC24 -91: For Omron Valve size Pilot specification 10:10mm width Blank: Internal pilot 15:15mm width G : External pilot 18:18mm width 16 points CompoBus/D Varies depending on the mounted number of single solenoids, double solenoids, and block-off plates. The number of controlled solenoids should be designated at the maximum number of control points or less. 8 units Precautions for Order Code Manifold Order Code Example (8 units of F10 Series) F10M8SL-J5R-91-W stn.1∼ 5 stn.6∼ 7 stn.8 F10T0-A1-J5 DC24V F10T2-A1-J6 DC24V F10BPP-J6 Note: This order code example has no relation to the illustration at upper right. 556 ● Order for valves only Use the code Valve size Valve specification Operation method Manual override Valve output type Voltage to order. ● Wiring connection specification Blank (packed wiring) : Wiring is made accordance with the mounted valve specifications. -W (double wiring) : Wiring is always for the double solenoid, regardless of the mounted valve specifications. Caution: Be aware that the block-off plate wiring is always double wiring (allocated 2 control points to 1 unit) regardless of the wiring connection specification. 557 SOLENOID VALVES F SERIES PC Board Manifold, Pin Locations by Wiring Specification (TOP VIEW) Flat cable connector (20-pin) ●-F200 (Maximum control point 16 points) ●-F201 (Maximum control point 16 points) Triangle mark Triangle mark 19 17 15 13 9 7 5 3 1 11 12 13 14 15 16 17 18 19 20 20 18 16 14 12 10 11 8 6 4 2 1 2 1∼16 : Control pin 17, 18 : Minus pin (Short-circuited inside) 19, 20 : Plus pin (Short-circuited inside) 111∼8 11∼18 9, 19 10, 20 Note 3 4 5 6 7 8 9 10 : : : : : Control pin Control pin Minus pin (Short-circuited inside) Plus pin (Short-circuited inside) Connector pin No. are allocated for convenience. Use the ▽ mark as the standard. Remark : The -F201 corresponds Koganei's pin locations for the PC wiring system (wire-saving unit). For details, see the PC wiring system on p. 981. Remark: Socket and strain relief for flat cable included at time of delivery. ※ For the relationship between the pin No. (terminal No.) and the corresponding solenoid, see p. 559. Detailed Diagram of Wiring System ●Plus common -F200 : 19,20 -F201 : 10,20 Power supply connection terminal Note Solenoid 1 -F200 : 1∼16 -F201 : 1∼8, 11∼18 Solenoid n -F200 : 17,18 -F201 : 9,19 Note: For connecting a power line to the PC board manifold power connection terminal, see the "PC Board Manifold" precautions on p.513. 558 ● Various dedicated cable assemblies are available. See p. 1033 for details. Pin No. and Corresponding Solenoid (For PC Board Manifold A and F Type) The examples below show the relationship between the PC board manifold pin No. and the corresponding solenoid. The mounting example shows the maximum number of control points in use. Flat cable connector (20-pin) ●Wiring specification -F200 (Maximum control point 16 points) (TOP VIEW) Example 1 Station 1 2 3 4 5 6 7 8 F10M16APJ-F200-S stn.1∼15 F10T1-A1-PP DC24V stn.16 F10BPC 9 F10M16APJ-F200-S 10 11 12 13 14 15 16 Triangle mark 19 17 15 13 9 7 5 3 1 20 18 16 14 12 10 11 8 6 4 2 19 17 15 13 11 9 A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B Left side Right side Number of units : 16 units Wiring specification : -F200 Wiring connection -S (single wiring) specification : Pin No. Valve No. Single solenoid 1 3 4 5 6 7 8 A B A B A B A B A B A B A B Left side 3 1 8 6 4 2 − 16A 14A 12A 10A 8A 6A 4A 2A Block-off plate (TOP VIEW) 2 5 F10M8APJ-F200-W stn.1∼4 F10T1-A1-PP DC24V F10M8APJ-F200-W stn.5∼7 F10T2-A1-PP DC24V F10M8APJ-F200-W stn.8 F10BPC Triangle mark 19 17 15 13 9 7 5 3 1 20 18 16 14 12 10 11 8 6 4 2 19 17 15 13 11 9 Right side Number of units : 8 units Wiring specification : -F200 Wiring connection -W (double wiring) specification : Pin No. Valve No. Valve No. Single solenoid + + 5 3 1 − 8A 7A 6A 5A 4A 3A 2A 1A 20 18 16 14 12 10 Pin No. 7 8 6 4 2 − 8B 7B 6B 5B 4B 3B 2B 1B Block-off plate Double solenoid Flat cable connector (20-pin) ●Wiring specification -F201 (Maximum control point 16 points) (TOP VIEW) Example 1 Station 1 2 3 4 5 6 7 8 F10M16APJ-F201-S stn.1∼15 F10T1-A1-PP DC24V F10M16APJ-F201-S stn.16 F10BPC 9 10 11 12 13 14 15 16 Triangle mark 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B Left side Right side Number of units : 16 units Wiring specification : -F201 Wiring connection -S (single wiring) specification : Pin No. 11 12 13 14 15 16 17 18 19 20 Valve No. 9A 10A 11A 12A 13A 14A 15A 16A − + 9 10 Valve No. 1A 2A 3A 4A 5A 6A 7A 8A − + Pin No. Single solenoid Example 2 Station 1 2 3 4 5 6 7 8 Block-off plate 1 2 3 5 4 (TOP VIEW) F10M8APJ-F201-W stn.1∼4 F10T1-A1-PP DC24V F10M8APJ-F201-W stn.5∼7 F10T2-A1-PP DC24V F10M8APJ-F201-W stn.8 F10BPC 6 8 Triangle mark 11 12 13 14 15 16 17 18 19 20 1 2 3 7 4 5 6 7 8 9 10 A B A B A B A B A B A B A B Left side Right side Number of units : 8 units Wiring specification : -F201 Wiring connection -W (double wiring) specification : Pin No. Valve No. 5A 5B 6A 6B 7A 7B 8A 8B − + 9 10 Valve No. 1A 1B 2A 2B 3A 3B 4A 4B − + Pin No. Single solenoid Block-off plate Double solenoid 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 Caution: Connector pin No. are allocated for convenience. Caution: Use the ▽ mark as a reference. Notes: 1. The valve No.1A, 1B, 2A, 2B… numbers show the stn. numbers in order, while the letters A and B show the A and B sides of the solenoid. 2. The stn. No. are counted from the left, 1, 2…, with the solenoid on top and the valve in front. 559 SOLENOID VALVES F SERIES Station + 7 − 15A 13A 11A 9A 7A 5A 3A 1A 20 18 16 14 12 10 Pin No. Valve No. Example 2 + Split Manifold Plug-In Type, Pin (Terminal) Locations by Wiring Specification (TOP VIEW) Flat cable connector (10-pin) Flat cable connector (20-pin) D sub connector (25-pin) ●-F100 (Maximum control point 8 points) ●-F200 (Maximum control point 16 points) ●-D250 (Maximum control point 16 points) Triangle mark Triangle mark 9 7 5 3 1 19 17 15 13 9 7 5 3 1 10 8 6 4 2 20 18 16 14 12 10 11 8 6 4 2 1 Triangle mark 9 7 5 3 1 11 12 13 14 15 16 17 18 19 20 10 8 6 4 2 1 2 3 4 5 6 7 8 9 10 9 8 11 10 13 12 15 14 17 16 19 18 21 20 23 22 25 24 ●-D251 Pin locations based on JIS (Maximum control point 20 points) 1∼8 : 11∼18 : 9, 19: 10, 20 : Note : Control pin Control pin Minus pin (Short-circuited within the wiring block) Plus pin (Short-circuited within the wiring block) Connector pin No. are allocated for convenience. Use the ▽ mark as the standard. ● Various dedicated cable assemblies are available. Remark : The -F201 corresponds Koganei's pin See p. 1033 for details. locations for the PC wiring system (wiresaving unit). For details, see the PC wiring system on p. 981. 1∼8 : Control pin 9 : Minus pin 10 : Plus pin 7 6 Caution: The above pin No. are conveniently allocated based on the solenoid valve wiring sequence. Caution: Differs from the pin locations and pin No. (marked) regulated (JIS-X5101) for the data circuit end (DCE) device. ●-F201 (Maximum control point 16 points) Triangle mark 5 4 1∼16 : Control pin 20, 21, 22 : Minus pin (Short-circuited within the wiring block) 23, 24, 25 : Plus pin (Short-circuited within the wiring block) 1∼8 : Control pin 1∼16 : Control pin 9, 10 : Common pin (Short-circuited within the wiring block) 17, 18 : Minus pin (Short-circuited within the wiring block) 19, 20 : Plus pin (Short-circuited within the wiring block) ●-F101 (Maximum control point 8 points) 3 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1∼10, 14∼23 : Control pin 12, 13 : Minus pin (Short-circuited within the wiring block) 24, 25 : Plus pin (Short-circuited within the wiring block) Flat cable connector (26-pin) Terminal block type (19 terminals, M3 thread) ●-F260 (Maximum control point 20 points) ●-T200 (Maximum control point 18 points) Triangle mark 3 1 25 23 21 19 17 15 13 11 9 7 5 3 1 26 24 22 20 18 16 14 12 10 8 6 4 2 2 5 4 7 6 9 8 11 10 12 13 17 COM 15 14 16 18 1∼18 : Control terminal COM : Common terminal 1∼20 : Control pin Caution: Set the tightening torque for terminal screw 23, 24 : Minus pin (Short-circuited within the wiring block) (M3) to 49.0N・cm{5.0kgf・cm} or less. 25, 26 : Plus pin (Short-circuited within the wiring block) ※ For the relationship between the pin No.(terminal No.) and the corresponding solenoid, see p.561∼565. Detailed Diagram of Wiring System Flat cable connector and D sub connector (DC12, 24V) -F100 : 9,10 -F101 : 10 -F200 : 19,20 -F201 : 10,20 -F260 : 25,26 -D250 : 23,24,25 -D251 : 24,25 ●Plus common Power supply connection terminal LED for power supply Solenoid 1 Solenoid n Wrong polarity prevention diode Terminal block (For DC12, 24V specification) -F100 : 1∼8 -F101 : 1∼8 -F200 : 1∼16 -F201 : 1∼8, 11∼18 -F260 : 1∼20 -D250 : 1∼16 -D251 : 1∼10, 14∼23 -F100 : None -F101 : 9 -F200 : 17,18 -F201 : 9,19 -F260 : 23,24 -D250 : 20,21,22 -D251 : 12,13 D sub connector (For AC100V specification) -D250 : 23,24,25 -D251 : 24,25 1 Power supply connection terminal AC100V Solenoid -D250 : 1∼16 -D251 : 1∼10, 14∼23 n Not available AC200V Solenoid -D250 : 20,21,22 -D251 : 12,13 Terminal block (For AC100V specification) COM (19) ●Plus common Solenoid Solenoid COM plus terminal (19) Solenoid 1 560 18 Solenoid 1 18 Pin No. (Terminal No.) and Corresponding Solenoid (For Split Manifold Plug-in Type) The examples below show the relationship between the split manifold pin No. and the corresponding solenoid. The mounting example shows the maximum number of control points in use. Flat cable connector (10-pin) ●Wiring specification -F100 (Maximum control point 8 points) Example 1 1st unit F10M5PJ-JR-F100 DC24V stn.1∼2 F10T1-A1 DC24V stn F10M5PJ-JR-F100 DC24V stn.3∼4 F10T2-A1 DC24V 1 2 3 4 5 F10M5PJ-JR-F100 DC24V stn.5 F10BPP A B A B A B A B Left side (TOP VIEW) Triangle mark 9 7 5 3 1 10 8 6 4 2 Right side Number of units : 5 units Wiring specification : -F100 Wiring connection specification : Blank (packed wiring) Pin No. 9 Pin No. Cover 1st unit 10 5 3 1 8 6 4 2 + 5B 4B 3B 2A Valve No. Block-off plate Double solenoid Single solenoid Example 2 7 + 5A 4A 3A 1A Valve No. F10M4PJ-JR-F100-W DC24V stn.1∼2 F10T1-A1 DC24V stn F10M5PJ-JR-F100-W DC24V stn.3∼4 F10T2-A1 DC24V 1 2 3 4 A B A B A B A B Left side (TOP VIEW) Triangle mark 9 7 5 3 1 10 8 6 4 2 Right side Number of units : 4 units Wiring specification : -F100 Wiring connection specification : -W (double wiring) Pin No. 9 10 3 1 8 6 4 2 + 4B 3B 2B 1B Valve No. Single solenoid 5 + 4A 3A 2A 1A Valve No. Pin No. Cover 7 Double solenoid Example 1 1st unit F10M5PJ-JR-F101 DC24V stn.1∼2 F10T1-A1 DC24V F10M5PJ-JR-F101 DC24V stn.3∼4 F10T2-A1 DC24V stn 1 2 3 4 5 F10M5PJ-JR-F101 DC24V stn.5 F10BPP A B A B A B A B Left side (TOP VIEW) SOLENOID VALVES F SERIES Flat cable connector (10-pin) ●Wiring specification -F101 (Maximum control point 8 points) Triangle mark 9 7 5 3 1 10 8 6 4 2 Right side Number of units : 5 units Wiring specification : -F101 Wiring connection specification : Blank (packed wiring) Pin No. 9 1st unit 10 1 8 6 4 2 + 5B 4B 3B 2A Valve No. F10M4PJ-JR-F101-W DC24V stn.1∼2 F10T1-A1 DC24V F10M5PJ-JR-F101-W DC24V stn.3∼4 F10T2-A1 DC24V stn 1 3 Block-off plate Double solenoid Single solenoid Example 2 5 − 5A 4A 3A 1A Valve No. Pin No. Cover 7 2 3 4 A B A B A B A B Left side (TOP VIEW) Triangle mark 9 7 5 3 1 10 8 6 4 2 Right side Number of units : 4 units Wiring specification : -F101 Wiring connection specification : -W (double wiring) Pin No. Valve No. Pin No. Valve No. Cover Single solenoid 9 7 5 3 1 − 4A 3A 2A 1A 10 8 6 4 2 + 4B 3B 2B 1B Double solenoid Notes: 1. The valve No.1A, 1B, 2A, 2B… numbers show the stn. numbers in order, while the letters A and B show the A and B sides of the solenoid. 2. The stn. No. are counted from the left, 1, 2…, with the solenoid on top and the valve in front. 3. If selecting wiring connection specification -W, all wiring becomes double wiring, regardless of valve specifications. 4. Be aware that the block-off plate is always double wiring (allocated 2 control pins to 1 unit), regardless of the wiring connection specifications. 5. Connector pin No. are allocated for convenience. Use the ▽mark as the standard. 561 Pin No. (Terminal No.) and Corresponding Solenoid (For Split Manifold Plug-in Type) The examples below show the relationship between the PC board manifold pin No. and the corresponding solenoid. The mounting example shows the maximum number of control points in use. Flat cable connector (20-pin) ●Wiring specification -F200 (Maximum control point 16 points) (TOP VIEW) Example 1 1st unit stn 1 2 F10M10PJ-JR-F200 DC24V stn.1∼4 F10T1-A1 DC24V F10M10PJ-JR-F200 DC24V stn.5∼9 F10T2-A1 DC24V 3 4 5 6 7 8 9 10 F10M10PJ-JR-F200 DC24V stn.10 F10BPP A B A B A B A B A B A B A B A B A B Left side Triangle mark 19 17 15 13 9 7 5 3 1 20 18 16 14 12 10 11 8 6 4 2 Right side Number of units : 10 units Wiring specification : -F200 Wiring connection specification : Blank (packed wiring) Pin No. 19 17 15 13 11 Valve No. Pin No. Cover + 9 20 18 16 14 12 10 Valve No. + 7 5 3 1 − 10A 9A 8A 7A 6A 5A 3A 1A 8 6 4 2 − 10B 9B 8B 7B 6B 5B 4A 2A Block-off plate Single solenoid (TOP VIEW) Example 2 1st unit Double solenoid stn 1 2 F10M8PJ-JR-F200-W DC24V stn.1∼4 F10T1-A1 DC24V F10M8PJ-JR-F200-W DC24V stn.5∼7 F10T2-A1 DC24V 3 4 5 6 7 8 F10M8PJ-JR-F200-W DC24V stn.8 F10BPP A B A B A B A B A B A B A B Left side Triangle mark 19 17 15 13 9 7 5 3 1 20 18 16 14 12 10 11 8 6 4 2 Right side Number of units : 8 units Wiring specification : -F200 Wiring connection specification : -W (double wiring) Pin No. 19 17 15 13 11 Valve No. Valve No. + 7 5 3 1 − 8A 7A 6A 5A 4A 3A 2A 1A 20 18 16 14 12 10 Pin No. Cover + 9 8 6 4 2 − 8B 7B 6B 5B 4B 3B 2B 1B Block-off plate Single solenoid Double solenoid Flat cable connector(20-pin) ●Wiring specification -F201 (Maximum control point 16 points) (TOP VIEW) Example 1 1st unit stn 1 2 F10M10PJ-JR-F201 DC24V stn.1∼4 F10T1-A1 DC24V F10M10PJ-JR-F201 DC24V stn.5∼9 F10T2-A1 DC24V 3 4 5 6 7 8 9 10 F10M10PJ-JR-F201 DC24V stn.10 F10BPP A B A B A B A B A B A B A B A B A B Left side Triangle mark 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 Right side Number of units : 10 units Wiring specification : -F201 Wiring connection specification : Blank (packed wiring) Pin No. 11 12 13 14 15 16 17 18 19 20 Valve No. 7A 7B 8A 8B 9A 9B 10A 10B − + 9 10 Valve No. 1A 2A 3A 4A 5A 5B 6A 6B − + Pin No. Cover 1 2 3 5 4 6 7 8 Block-off plate Single solenoid Double solenoid (TOP VIEW) Example 2 1st unit stn 1 2 F10M8PJ-JR-F201-W DC24V stn.1∼4 F10T1-A1 DC24V F10M8PJ-JR-F201-W DC24V stn.5∼7 F10T2-A1 DC24V 3 4 5 6 7 8 F10M8PJ-JR-F201-W DC24V stn.8 F10BPP A B A B A B A B A B A B A B Left side Triangle mark 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 Right side Number of units : 8 units Wiring specification : -F201 Wiring connection specification : -W (double wiring) Pin No. Valve No. 5A 5B 6A 6B 7A 7B 8A 8B − + 9 10 Valve No. 1A 1B 2A 2B 3A 3B 4A 4B − + Pin No. Cover Block-off plate Single solenoid Double solenoid 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 Note: Connector pin No. are allocated for convenience. Note: Use the ▽ mark as the standard. Notes: 1. The valve No.1A, 1B, 2A, 2B… numbers show the stn. numbers in order, while the letters A and B show the A and B sides of the solenoid. 2. The stn. No. are counted from the left, 1, 2…, with the solenoid on top and the valve in front. 3. If selecting wiring connection specification -W, all wiring becomes double wiring, regardless of valve specifications. 4. Be aware that the block-off plate is always double wiring (allocated 2 control pins to 1 unit), regardless of the wiring connection specifications. 5. Connector pin No. are allocated for convenience. Use the ▽ mark as the standard. 562 8 Pin No. (Terminal No.) and Corresponding Solenoid (For Split Manifold Plug-in Type) The examples below show the relationship between the split manifold pin No. and the corresponding solenoid. The mounting example shows the maximum number of control points in use. Flat cable connector (26-pin) ●Wiring specification -F260 (Maximum control point 20 points) Example 1 1st unit stn 1 2 (TOP VIEW) F10M12PJ-JR-F260 DC24V stn.1∼4 F10T1-A1 DC24V F10M12PJ-JR-F260 DC24V stn.5∼11 F10T2-A1 DC24V 3 4 5 6 7 8 9 10 11 12 F10M12PJ-JR-F260 DC24V stn.12 F10BPP 25 23 21 19 17 15 13 11 A B A B A B A B A B A B A B A B A B A B A B Left side Triangle mark 9 7 5 3 1 26 24 22 20 18 16 14 12 10 8 6 4 2 Right side Number of units : 12 units Wiring specification : -F260 Wiring connection specification : Blank (packed wiring) Pin No. Valve No. Pin No. Cover Valve No. 25 23 21 19 17 15 13 11 + − 9 7 26 24 22 20 18 16 14 12 10 + − 5 3 1 12A 11A 10A 9A 8A 7A 6A 5A 3A 1A 8 6 4 2 12B 11B 10B 9B 8B 7B 6B 5B 4A 2A Block-off plate Single solenoid Example 2 1st unit stn 1 2 Double solenoid (TOP VIEW) F10M10PJ-JR-F260-W DC24V stn.1∼6 F10T1-A1 DC24V F10M10PJ-JR-F260-W DC24V stn.7∼9 F10T2-A1 DC24V 3 4 5 6 7 8 9 10 F10M10PJ-JR-F260-W DC24V stn.10 F10BPP 25 23 21 19 17 15 13 11 A B A B A B A B A B A B A B A B A B Left side Triangle mark 9 7 5 3 1 26 24 22 20 18 16 14 12 10 8 6 4 2 Right side Number of units : 10 units Wiring specification : -F260 Wiring connection specification : -W (double wiring) Pin No. Valve No. Pin No. Cover Valve No. Single solenoid 25 23 21 19 17 15 13 11 + − 9 26 24 22 20 18 16 14 12 10 + − 7 5 3 1 10A 9A 8A 7A 6A 5A 4A 3A 2A 1A 8 6 4 2 10B 9B 8B 7B 6B 5B 4B 3B 2B 1B Block-off plate Double solenoid SOLENOID VALVES F SERIES Notes: 1. The valve No.1A, 1B, 2A, 2B… numbers show the stn. numbers in order, while the letters A and B show the A and B sides of the solenoid. 2. The stn. No. are counted from the left, 1, 2…, with the solenoid on top and the valve in front. 3. If selecting wiring connection specification -W, all wiring becomes double wiring, regardless of valve specifications. 4. Be aware that the block-off plate is always double wiring (allocated 2 control pins to 1 unit), regardless of the wiring connection specifications. 5. Connector pin No. are allocated for convenience. Use the ▽ mark as the standard. 563 Pin No. (Terminal No.) and Corresponding Solenoid (For Split Manifold Plug-in Type) The examples below show the relationship between the split manifold pin No. and the corresponding solenoid. The mounting example shows the maximum number of control points in use. D sub connector (25-pin) ●Wiring specification -D250 (Maximum control point 16 points) Example 1 1st unit F10M10PJ-JR-D250 DC24V stn.1∼4 F10T1-A1 DC24V F10M10PJ-JR-D250 DC24V stn.5∼9 F10T2-A1 DC24V 3 4 5 6 7 8 9 10 F10M10PJ-JR-D250 DC24V stn.10 F10BPP Caution: The connector pin No. are conveniently allocated based on the solenoid valve wiring sequence. Differs from the pin locations and pin No. (printed) regulated (JIS-X5101) for the data circuit end (DCE) device. (TOP VIEW) stn 1 2 A B A B A B A B A B A B A B A B A B Left side 1 Right side 3 2 Number of units : 10 units Wiring specification : -D250 Wiring connection specification : Blank (packed wiring) Pin No. 5 4 1 7 6 9 8 3 11 10 5 13 12 7 15 14 9 17 16 19 18 21 20 23 22 25 24 11 13 15 17 19 21 23 25 − Valve No. 1A 3A 5A 6A 7A 8A 9A 10A + + Cover 2 Pin No. Block-off plate Single solenoid Example 2 1st unit Double solenoid F10M8PJ-JR-D250-W DC24V stn.1∼4 F10T1-A1 DC24V F10M8PJ-JR-D250-W DC24V stn.5∼7 F10T2-A1 DC24V 3 4 5 6 7 8 F10M8PJ-JR-D250-W DC24V stn.8 F10BPP 4 6 8 10 12 14 16 18 20 22 24 − 2A 4A 5B 6B 7B 8B 9B 10B Valve No. − + (TOP VIEW) stn 1 2 A B A B A B A B A B A B A B Left side 1 Right side 3 2 Number of units : 8 units Wiring specification : -D250 Wiring connection specification : -W (double wiring) Pin No. 5 4 1 7 6 3 9 8 11 10 5 13 12 7 15 14 9 17 16 19 18 21 20 23 22 25 24 11 13 15 17 19 21 23 25 − Valve No. 1A 2A 3A 4A 5A 6A 7A 8A Cover 2 Pin No. Single solenoid 4 6 8 + 10 12 14 16 18 20 22 24 − 1B 2B 3B 4B 5B 6B 7B 8B Valve No. Block-off plate Double solenoid + − + D sub connector (25-pin) ●Wiring specification -D251 pin locations based on JIS (Maximum control point 20 points) Example 1 1st unit stn 1 2 F10M12PJ-JR-D251 DC24V stn.1∼4 F10T1-A1 DC24V F10M12PJ-JR-D251 DC24V stn.5∼11 F10T2-A1 DC24V 3 4 5 6 7 8 9 10 11 12 F10M12PJ-JR-D251 DC24V stn.12 F10BPP (TOP VIEW) A B A B A B A B A B A B A B A B A B A B A B Left side 1 Right side Number of units : 12 units Wiring specification : -D251 Wiring connection specification : Blank (packed wiring) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 Valve No. 1A 2A 3A 4A 5A 5B 6A 6B 7A 7B Cover Example 2 1st unit stn 1 (TOP VIEW) 1 A B A B A B A B A B A B A B A B A B Left side Number of units : 10 units Wiring specification : -D251 Wiring connection specification : -W (double wiring) Pin No. Block-off plate Double solenoid 3 4 5 6 7 8 9 10 11 12 13 1 2 3 4 5 6 7 8 9 10 11 12 13 Valve No. 1A 1B 2A 2B 3A 3B 4A 4B 5A 5B Pin No. Cover 2 14 15 16 17 18 19 20 21 22 23 24 25 Right side Valve No. − − 14 15 16 17 18 19 20 21 22 23 24 25 6A 6B 7A 7B 8A 8B 9A 9B 10A 10B + Notes: 1. The valve No.1A, 1B, 2A, 2B… numbers show the stn. numbers in order, while the letters A and B show the A and B sides of the solenoid. 2. The stn. No. are counted from the left, 1, 2…, with the solenoid on top and the valve in front. 3. If selecting wiring connection specification -W, all wiring becomes double wiring, regardless of valve specifications. 4. Be aware that the block-off plate is always double wiring (allocated 2 control pins to 1 unit), regardless of the wiring connection specifications. 564 + Double solenoid F10M10PJ-JR-D251-W DC24V stn.1∼6 F10T1-A1 DC24V F10M10PJ-JR-D251-W DC24V stn.7∼9 F10T2-A1 DC24V 2 3 4 5 6 7 8 9 10 F10M10PJ-JR-D251-W DC24V stn.10 F10BPP Single solenoid 8A 8B 9A 9B 10A 10B 11A 11B 12A 12B + Valve No. Block-off plate − 14 15 16 17 18 19 20 21 22 23 24 25 Pin No. Single solenoid − + Pin No. (Terminal No.) and Corresponding Solenoid (For Split Manifold Plug-in Type) The examples below show the relationship between the split manifold terminal No. and the corresponding solenoid. The mounting example shows the maximum number of control points in use. Terminal block type (19 terminals, M3 thread) ●Wiring specification -T200 (Maximum control point18 points) Example 1 1st unit stn 1 2 3 F10M12PJ-JR-T200 DC24V stn.1∼6 F10T1-A1 DC24V F10M12PJ-JR-T200 DC24V stn.7∼11 F10T2-A1 DC24V 4 5 6 7 8 9 10 11 12 F10M12PJ-JR-T200 DC24V stn.12 F10BPP (TOP VIEW) 5 4 2 7 6 9 8 11 13 10 12 3 5 15 14 17 COM 16 18 Right side 1 3 5 7 9 11 13 15 17 COM 2 4 6 8 10 12 14 16 18 Left side 3 1 A B A B A B A B A B A B A B A B A B A B A B Number of units : 12 units Wiring specification : -T200 Wiring connection specification : Blank (packed wiring) Terminal No. 1 Valve No. 7 9 11 13 15 17 COM 1A 3A 5A 7A 8A 9A 10A 11A 12A + 2 Terminal No. 4 6 8 10 12 14 16 18 Cover 2A 4A 6A 7B 8B 9B 10B 11B 12B Valve No. Block-off plate Single solenoid Example 2 1st unit stn 1 2 3 Double solenoid F10M9PJ-JR-T200-W DC24V stn.1∼6 F10T1-A1 DC24V F10M9PJ-JR-T200-W DC24V stn.7∼8 F10T2-A1 DC24V 4 5 6 7 8 9 F10M9PJ-JR-T200-W DC24V stn.9 F10BPP A B A B A B A B A B A B A B A B 3 1 2 5 4 7 6 9 8 11 13 10 12 3 5 15 14 17 COM 16 18 Right side 1 3 5 7 9 11 13 15 17 COM 2 4 6 8 10 12 14 16 18 Left side (TOP VIEW) Number of units : 9 units Wiring specification : -T200 Wiring connection specification : -W (double wiring) Terminal No. 1 Terminal No. Cover 7 9 11 13 15 17 COM Valve No. 1A 2A 3A 4A 5A 6A 7A 8A 9A + Valve No. 2 4 6 8 10 12 14 16 18 1B 2B 3B 4B 5B 6B 7B 8B 9B Block-off plate Single solenoid Double solenoid SOLENOID VALVES F SERIES Notes: 1. The valve No.1A, 1B, 2A, 2B… numbers show the stn. numbers in order, while the letters A and B show the A and B sides of the solenoid. 2. The stn. No. are counted from the left, 1, 2…, with the solenoid on top and the valve in front. 3. If selecting wiring connection specification -W, all wiring becomes double wiring, regardless of valve specifications. 4. Be aware that the block-off plate is always double wiring (allocated 2 control terminals to 1 unit), regardless of the wiring connection specifications. 565 566 SOLENOID VALVES SERIES INDEX 568 Dimensions of Single Valve Unit 572 Dimensions of Monoblock Manifold 575 Dimensions of PC Board Manifold 577 Dimensions of Split Manifold Non-Plug-in Type 578 Dimensions of Split Manifold Plug-in Type 579 Dimensions of Serial Transmission Compatible Manifold 582 SOLENOID VALVES F SERIES Specifications 567 F10 SERIES SPECIFICATIONS Specifications Basic Models and Functions Basic model Item F10T3 F10T4 F10T5 F10T1 F10T0 F10T2 Number of positions 2 positions 3 positions Number of ports 5 Valve function For single solenoid only For both single and double solenoid All port block, ABR connection, PAB connection Remark: For the optional specifications and order code, see p.532~556. Specifications Basic model Item F10T0 F10T1 F10T2 F10T3 F10T4 F10T5 F10T0G F10T1G F10T2G F10T3G F10T4G F10T5G Media F10T0V F10T1V F10T2V F10T3V Air Operation method Internal pilot type Effective area〔CV〕Note1 mm2 5〔0.28〕 External pilot type (for positive pressure) 4.5〔0.25〕 Port size Note2 5〔0.28〕 External pilot type (for vacuum) 4.5〔0.25〕 5〔0.28〕 4.5〔0.25〕 M5× 0.8, fittings for φ4 andφ6, Rc1/8 Lubrication Not required 0.2∼0.7MPa{2∼7.1kgf/cm2} Main valve Operating pressure range External pilot 0∼0.7MPa{0∼7.1kgf/cm2}Note3 0.15MPa∼−100kPa{1.5kgf/cm2∼−750.1mmHg} 0.2∼0.7MPa{2∼7.1kgf/cm2}Note3 0.2∼0.7MPa{2∼7.1kgf/cm2} MPa {kgf/cm2} Proof pressure Response time Note4 ms ON/OFF time 1.05{10.7} DC12V, DC24V Max. 15/20 Max. 15/25 Max. 15/20 Max. 15/25 Max. 15/20 Max. 15/25 AC100V Max. 15/20 Max. 15/25 Max. 15/20 Max. 15/25 Max. 15/20 Max. 15/25 Maximum operating frequency Hz Minimum time to energize for self holding Note5 ms 5 50 50 Operating temperature range (atmosphere and media) ℃ 2 m/s{G} Shock resistance 50 5∼50 1373 {140.0} 294.2 {30.0} (Axial direction 294.2 {30.0}) 1373 {140.0} 294.2 {30.0} (Axial direction 294.2 {30.0}) Mounting direction 1373 {140.0} 294.2 {30.0} (Axial direction 294.2 {30.0}) Any Notes: 1. 2. 3. 4. For details, see the effective area on p.569. For details, see the port size on p.569. When the main valve pressure is 0.2~0.7MPa, set the external pilot pressure to the main valve pressure or higher, and 0.7MPa or less. Values when air pressure is 0.5MPa. For switching phase timing, add a maximum of 5 ms to the response time of AC specification. The values for 2-position valves are when used as a single solenoid, and the values for 3-position valves are those switching from the neutral state of all port block. 5. When used as a double solenoid valve. Excludes T0. Remark: Conversion to psi., 1MPa=145psi., 1kgf/cm2=14.2psi., e.g. 0.2MPa=29psi. Solenoid Specifications Rated voltage Item Voltage range V Rated frequency Current DC24V DC12V 10.8∼13.2 21.6∼26.4 90∼110 (12±10%) (24±10%) (100±10%) Hz mA(r.m.s) Starting (When rated voltage is applied) Power consumption Allowable leakage current LED indicator color Note3 Surge suppression (as standard) 60 10Note1 10Note1 10Note1 76 38 W 0.9 0.9 1.0VA mA 4.0 2.0 2.0 Type B Min. 100 MΩ SA:Red, SB:Green SA:Red, SB:Green Flywheel diode Notes: 1. Since the AC types have built-in bridge diodes, the starting current and energizing current value are virtually the same. 2. Value at DC500V megger. 3. The indicator color for T0 is red only. 568 50 10Note1 Energizing Type of insulation Insulation resistance Note 2 AC100V SA:Red, SB:Green Bridge diode Cylinder Operating Speed Flow Rate How to obtain the cylinder speed Maximum operating speed Cylinder stops Cushion impact Cylinder starts Time 1000 800 φ20 φ25 φ32 φ40 φ50 600 400 200 0 Delay time 0.3 0.2 0.1 0 0.1 100 200 300 400 500 How to read the graph If supply pressure is 0.5MPa and flow rate is 240R/min (ANR), the valve output pressure becomes 0.4MPa. Delay time 0.5MPa 0.4 Flow rate R/min (ANR) % Measuring conditions s 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0.7 0.6 0.5 0.4 0.3 0.2 0.5 10 20 30 40 50 60 70 Load ratio ●Air pressure:0.5MPa{5.1kgf/cm2} ●Piping (outer diameter×inner diameter× length):φ6×φ4×1000mm ●Fitting:Quick fitting TS6-01 Load ●Load ratio= (%) Cylinder theoretical thrust Load ●Cylinder stroke:150mm MPa 0.6 Valve output pressure t3 t2 Maximum operating speed Cylinder stroke Solenoid valve energized t1 Supply pressure MPa 0.7 mm/s 1200 φ50 φ32 ,φ40 φ25 φ20 10 20 30 40 50 60 70 % Load ratio Note:Delay time may vary according to the cylinder stroke. Port Size Description/piping specification PR P2 A, B P, R With sub-base M5×0.8 M5×0.8 Rc1/8 Rc1/8 With female thread block ― ― M5×0.8 M5×0.8 With different size fitting block ― ― For both φ4 andφ6 M5×0.8 ― ― φ4 or φ6 M5×0.8 Monoblock type with female thread block, or PC board type with female thread block M5×0.8 M5×0.8 M5×0.8 Rc1/8 Monoblock type with fitting block, or PC board type with fitting block M5×0.8 M5×0.8 For both φ4 and φ6 Rc1/8 Monoblock type with single size fitting block, or PC board type with single size fitting block M5×0.8 M5×0.8 φ4 or φ6 Rc1/8 Split type with female thread block, or serial transmission type with female thread block ― M5×0.8 M5×0.8 Rc1/4 Split type with fitting block, or serial transmission type with fitting block ― M5×0.8 For both φ4 and φ6 For both φ8 and φ10 Split type with single size fitting block, or serial transmission type with single size fitting block ― M5×0.8 φ4 or φ6 φ8, φ10 With single size fitting block Effective Area〔Cv〕 ●When using as a single unit Basic model F10T0□-F5 F10T1□-F5 F10T2□-F5 F10T3□-F5 F10T4□-F5 F10T5□-F5 F10T0□-F6 F10T1□-F6 F10T2□-F6 F10T3□-F6 F10T4□-F6 F10T5□-F6 mm2 ●When mounted on a manifold Manifold model Effective area〔Cv〕 Valve model 3.5〔0.19〕 F10T0□ F10T1□ F10T2□ F10T3□ F10T4□ F10T5□ 3.5〔0.19〕 F10T0□ F10T1□ F10T2□ F10T3□ F10T4□ F10T5□ Output port fitting for both φ4 and φ6 Output port female thread Output port φ4 fitting φ6 fitting mm2 F10M□F F10M□A F10M□N 4.5〔0.25〕 4.0〔0.22〕 5.0〔0.28〕 4.5〔0.25〕 4.0〔0.22〕 4.5〔0.25〕 3.5〔0.19〕 3.3〔0.18〕 4.3〔0.24〕 3.5〔0.19〕 3.3〔0.18〕 3.8〔0.21〕 Caution: When you use the individual air supply spacer or the individual air exhaust spacer, effective area decreases about 30%. 569 SOLENOID VALVES F SERIES Manifold Single unit ●F10 Series Mass Single Valve Unit Mass g F10T□□-FJ F10T□□ F10T□□-A1 F10T□□-A2 Output section Output section Output section Output section Output section Output section None With plate With plate With different size fitting block With φ4 fitting block With φ6 fitting block Input section Input section Input section Input section Input section Input section None None With A type sub-base None None None 50 53 113 61 63 66 F10T□□-FM F10T□□-F3 F10T□□-F4 F10T□□-F5 F10T□□-F6 Output section Output section Input section F10T□□-FJ6 F10T□□-FJ5 g With female thread block With different size fitting block With female thread block Output section Output section With φ4 fitting block With φ6 fitting block Input section Input section Input section Input section Input section None With female thread block With female thread block With female thread block With female thread block 57 69 65 71 74 Basic Type F10T0 is 9g less than the mass shown above. Monoblock Manifold Mass (included single valve unit) g Mass calculation of each unit A, B port output specifications Monoblock manifold Female thread Different size fitting block φ4 fitting block φ6 fitting block A type (97×n)+70 (101×n)+70 (103×n)+70 (106×n)+70 F type (76×n)+70 (80×n)+70 (82×n)+70 (85×n)+70 Calculation example : F10M8AM stn.1∼stn.8 F10T1-A1-PS DC24V (97×8)+70=846g When mounting a block-off plate, calculate the female thread specifications at 45g less than the above calculation results per unit, while the different size fitting specifications are 50g, the φ4 fitting specifications 52g, and the φ6 fitting specifications 55g less. When mounting the F10T0 specifications, subtract 9g per unit from the above calculation results. PC Board Manifold Mass (included single valves unit) g Mass calculation of each unit Circuit board and A, B port output specifications PC board manifold Female thread Different size fitting block φ4 fitting block φ6 fitting block A type (101×n)+70 (105×n)+70 (107×n)+70 (110×n)+70 F type (76×n)+70 (80×n)+70 (82×n)+70 (85×n)+70 Calculation example : connector section (2×n)+15 F10M8APM-F201-W stn.1∼stn.8 F10T1-A1-PP DC24V (101×8)+70+(2×8)+15=909g When mounting a block-off plate, calculate the female thread specifications at 45g less than the above calculation results per unit, while the different size fitting specifications are 50g, the φ4 fitting specifications 52g, and the φ6 fitting specifications 55g less. When mounting the F10T0 specifications, subtract 9g per unit from the above calculation results. 570 Mass Mass of Split Type Manifold and Serial Transmission Compatible Type The split manifold has the same mass as that for the combination of valve output and manifold output specifications. The mass can only change with selection of the type of input/output block. Mass of Split Manifold Non-Plug-in Type (included single valve unit) g Mass calculation of each unit Non-plug-in type A, B port output specifications Female thread Different size fitting block φ4 fitting block φ6 fitting block (70×n)+156 (74×n)+156 (76×n)+156 (79×n)+156 g Additional mass Piping block specification Female thread Different size fitting block φ8 fitting block φ10 fitting block 141 151 176 185 Calculation example : F10M8N-MR stn.1∼stn.8 F10T1-A1-PS DC24V (70×8)+156+141=857g When mounting a block-off plate, calculate the female thread specifications at 45g less than the above calculation results per unit, while the different size fitting specifications are 50g, the φ4 fitting specifications 52g, and the φ6 fitting specifications 55g less. When mounting the F10T0 specifications, subtract 9g per unit from the above calculation results. Mass of Split Manifold Plug-in Type/Serial Transmission Compatible Type (included single valve unit) g Mass calculation of each unit Plug-in type Serial transmission compatible type A, B port output specifications Female thread Different size fitting block φ4 fitting block φ6 fitting block (72×n)+156 (76×n)+156 (78×n)+156 (81×n)+156 g Additional mass Female thread Different size fitting block φ8 fitting block φ10 fitting block 141 151 176 185 g Additional mass Wiring block specification -F100, -F101 -F200, -F201, -F260 -D250, -D251 -T200 44 46 50 90 g Transmission block mass Serial transmission blockNote YS□□ YS391 160 110 Calculation example : F10M8PM-MR-F201 DC24V stn.1∼stn.8 F10T1-A1 DC24V (72×8)+156+141+46=919g When mounting a block-off plate, calculate the female thread specifications at 45g less than the above calculation results per unit, while the different size fitting specifications are 50g, the φ4 fitting specifications 52g, and the φ6 fitting specifications 55g less. When mounting the F10T0 specifications, subtract 9g per unit from the above calculation results. Note : For the serial transmission compatible manifold, add to the calculation the wiring block -F201(46g). 571 SOLENOID VALVES F SERIES Piping block specification F10 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F10T F10T Valve specification -F3-PS With output port different size fitting block With input port female thread block S type plug connector ※For T0 type dimensions, see p.573. (49) 40.5 12 10 27 5 A B Manual override ( 4 A)port 2-φ3.2 (Mounting hole) Quick fitting (φ4, φ6) 1.6 1.6 11 10 11.5 25.5 33 ( 2 B)port 2 (R2) 3 14.5 31 (P) 1 10 10 (R1 5 ) 62.7 110 3-M5×0.8 Mounting bracket(F10Z-21)Note 20 5 φ9.8 10 12 1.2 2-φ3.2 (Mounting hole) Note : The mounting bracket is additional part (sold separately). F10T Valve specification -F4-PS With output port female thread block With input port female thread block S type plug connector ※For T0 type dimensions, see p.573. 12 (35.5) 10 27 5 A B Manual override 4 (A)port 2-φ3.2 (Mounting hole) 110 3-M5×0.8 2-M5×0.8 1.6 62.7 10 11.5 25.1 11.8 33 14.5 2 (B)port 2 1.6 31 (P) 1 (R2) 3 10 10 ( 5 R1) Mounting bracket(F10Z-21)Note 20 10 5 12 1.2 2-φ3.2 (Mounting hole) Note :The mounting bracket is additional part (sold separately). 572 F10 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F10T0-F□-PS -F5: (46.1) -F6: (48.1) 12 -F5:37.6 -F6:39.6 (300) With output port single size fitting block With input port female thread block S type plug connector 10 27 Manual override (PR) 5 PUSH 17.1 11.8 10 LOCK 10 11.5 33 23 10 10 2-φ3.2 (Mounting hole) 2 (B)port 54.7 3-M5×0.8 3 (R2)port 6.5 1 (P)port 102 5 (R1)port 4 (A)port Single size fitting -F5:φ4 -F6:φ6 1.6 20 10 5 1.2 2-φ3.2 (Mounting hole) 12 Note :The mounting bracket is additional part (sold separately). SOLENOID VALVES F SERIES 1.6 573 F10 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F10T F10T Valve specification Operation method -A2-PS With A type sub-base S type plug connector ●Internal pilot specification A B Manual override M5×0.8 2-φ3.2 (Mounting hole) 3-Rc1/8 19.5 11 11 B side manual override 6 11 ( 3 R2) 2 (B) 3 ●For double solenoid ●or 3-position valve 25 PR (P) 1 62.7 50 44 18.8 12.4 4 (A) ( 5 R1) 110 2-Rc1/8 24 7.5 14.5 25 24 27 3 8 7.5 10 16.5 19 25 (51.5) Note : The T0 type is 8mm shorter for the total valve length (the end cover protrusion is 8mm shorter). ●External pilot specification A B Manual override 19.5 11 11 B side manual override 6 11 3 R2) ( 2 (B) 3 ●For double solenoid ●or 3-position valve 25 PR 1 (P) 62.7 50 44 18.8 10.9 4 (A) 5 R1) ( 110 3-Rc1/8 P2 9.7 M5×0.8 2-φ3.2 (Mounting hole) M5×0.8 6 (External pilot) 2-Rc1/8 24 7.5 16.5 25 24 27 3 8 7.5 10 16.5 19 25 (51.5) Note : The T0 type is 8mm shorter for the total valve length (the end cover protrusion is 8mm shorter). Options Made to Order ●L type plug connector : -PL ●Manual lever override (Scale 2/3, Unit mm) 43.5 A B 3 ( 2 B) Note : The T0 type is 8mm shorter for the total valve length (the end cover protrusion is 8mm shorter). 574 36.3 (R1 5 ) (R2) 3 (P) 1 ( 4 A) PR P2 99 A B F10 Series Dimensions of Monoblock Manifold A Type (Scale 1/3, Unit mm) F10M J AM Number of units F10MA Pilot specification (base piping type) Monoblock manifold A type With manifold output port different size fitting block S type plug connector L 14 10.510.5 14 (pitch) Unit dimensions Manual override L P 2 38.5 30.5 3 49.0 41.0 4 59.5 51.5 5 70.0 62.0 6 80.5 72.5 7 91.0 83.0 8 101.5 93.5 9 112.0 104.0 10 122.5 114.5 11 133.0 125.0 12 143.5 135.5 13 154.0 146.0 14 164.5 156.5 15 175.0 167.0 16 185.5 177.5 17 196.0 188.0 18 206.5 198.5 19 217.0 209.0 20 227.5 219.5 Number of units 26 A B A B A B 16 6 4-φ4.5 21.5 11 16.5 16 62.7 6-Rc1/8 (Both sides) 4 P stn.1 stn.2 stn.3 stn.4 10 4 Block-off plate 27 Quick fitting(φ4, φ6) 〔Can also select M5×0.8 female thread〕 10.5 11 32 (59.5) 2 B)port ( 4 A)port ( AL Number of units Pilot specification (base piping type) Monoblock manifold A type With manifold output port single size fitting block S type plug connector L 10.5 (pitch) 10.5 14 Manual override 26 2-M5 (PR) (Both sides) Unit dimensions 16 A A LOCK LOCK 54.7 LOCK PUSH LOCK B LOCK PUSH B 6-Rc1/8 (Both sides) 4 P -J5:18.6 -J6:20.6 2.5 11 PUSH 4-φ4.5 (Mounting hole) 56 102 62.7 110 A LOCK PUSH PUSH PUSH 8 24.5 (4) stn.1 stn.2 stn.3 stn.4 stn.5 10 P 38.5 30.5 3 49.0 41.0 4 59.5 51.5 5 70.0 62.0 6 80.5 72.5 7 91.0 83.0 8 101.5 93.5 9 112.0 104.0 10 122.5 114.5 11 133.0 125.0 12 143.5 135.5 13 154.0 146.0 14 164.5 156.5 15 175.0 167.0 16 185.5 177.5 17 196.0 188.0 18 206.5 198.5 19 217.0 209.0 20 227.5 219.5 32 11.8 27 Single size fitting -J5:φ4 -J6:φ6 (59.5) 50 -J5:126.1 -J6:128.1 3 (R2)port 16.5 16 1(P)port 41 L 2 Number of units 5 (R1)port 2 (B)port 10.1 F10M 56 129 2.5 24.5 8 41 PR ( ( 5 R1)(P) 1 3 R2) 50 P2 110 2-M5×0.8(Both sides) (For external pilot specification) 4 (A)port 575 SOLENOID VALVES F SERIES 2-M5×0.8(Both sides) F10 Series Dimensions of Monoblock Manifold F Type (Scale 1/3, Unit mm) F10M Number of units F10MF F (direct piping type) Monoblock manifold F type With valve output port different size fitting block S type plug connector L 19 Unit dimensions 10.5 10.5 19 (pitch) A B A B A B 4-φ4.5 9 9 9 18 P 9 stn.1 stn.2 stn.3 stn.4 Quick fitting(φ4, φ6) 10 〔Can also select M5×0.8 female thread〕 〔Can also select single size fitting〕 Block-off plate 26 40.5 21 (67) 49 15 14 11 25.5 11 110 2 B)port ( 62.7 14 14 22 (R2) 3 (P) 1 6-Rc1/8 (Both sides) 4 A)port ( PR (R1 5 ) 21.5 2-M5×0.8 (Both sides) Note : The T0 type is 8mm shorter for the total valve length (the end cover protrusion is 8mm shorter). 576 L P 2 48.5 30.5 3 59.0 41.0 4 69.5 51.5 5 80.0 62.0 6 90.5 72.5 7 101.0 83.0 8 111.5 93.5 9 122.0 104.0 10 132.5 114.5 11 143.0 125.0 12 153.5 135.5 13 164.0 146.0 14 174.5 156.5 15 185.0 167.0 16 195.5 177.5 17 206.0 188.0 18 216.5 198.5 19 227.0 209.0 20 237.5 219.5 Number of units Manual override F10 Series Dimensions of PC Board Manifold A Type, F Type (Scale 1/3, Unit mm) F10M J AP M Number of units F10MAPJ Pilot specification (base piping type) PC board manifold A type With manifold output port different size fitting block Note: The mounted valve example has -W wiring connection specification. Note: In wiring connection specification -S, the mounted valves are T0 or T1 type. Applicable connector:20-pinNote 〔MIL-C-83503 conformity〕 47 32 Note: The position of the groove preventing wrong insertions of -F200 is reversed to that of -F201. Illustration shows the -F201 case. 27 (59.5) Power supply connection terminal 10 stn.1 stn.2 stn.3 stn.4 stn.5 stn.6 L 26 14 10.5 10.5 14 16 2-M5×0.8(Both sides) (pitch) 6 Manual override 2-M5×0.8(Both sides) (For external pilot specification) 4-φ4.5 Unit dimensions L P 6 80.5 72.5 11 16.5 16 62.7 21.5 6-Rc1/8 (Both sides) 10.5 11 2 port (B) 4 P 4 Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 4 port (A) F10M Number of units 56 110 129 2.5 8 41 24.5 PR (R1) 5 (P) 1 (R2) 3 91 P2 50 10 Number of units 8 101.5 93.5 10 122.5 114.5 12 143.5 135.5 14 164.5 156.5 16 185.5 177.5 Note: Wiring connection specification For -S 6, 8,10,12,14,16 units For -W 6, 8 units FP (direct piping type) F10MFP PC board manifold F type With valve output port different size fitting block Power supply connection terminal Applicable connector:20-pinNote 〔MIL-C-83503 conformity〕 52 Note: The position of the groove preventing wrong insertions of -F200 is reversed to that of -F201. Illustration shows the -F201 case. (67) 40.5 26 Note: The mounted valve example has -W wiring connection specification. Note: In wiring connection specification -S, the mounted valves are T0 or T1 type. SOLENOID VALVES F SERIES A B A B A B A B A B 10 stn.1 stn.2 stn.3 stn.4 stn.5 stn.6 L 19 10.5 10.5 19 (pitch) Manual override Unit dimensions 2-M5×0.8 (Both sides) A B A B A B A B A B Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 〔Can also select single size fitting〕 4-φ4.5 6-Rc1/8 (Both sides) 9 9 18 21 10 49 14 15 9 25.5 11 62.7 11 2 port (B) 110 14 14 21.5 22 PR (R2) 3 (R1 5 ) (P) 1 84 4 A)port ( P 9 Note : The T0 type is 8mm shorter for the total valve length (the end cover protrusion is 8mm shorter). L P 6 90.5 72.5 Number of units 8 111.5 93.5 10 132.5 114.5 12 153.5 135.5 14 174.5 156.5 16 195.5 177.5 Note: Wiring connection specification For -S 6, 8,10,12,14,16 units For -W 6, 8 units 577 F10 Series Dimensions of Split Manifold Non-Plug-in Type (Scale 1/3, Unit mm) F10M Number of units N J M F10MNJ Pilot specification (base piping type) With manifold output port different size fitting block S type plug connector L1(L2) 28.5 4 Manual override Unit dimensions M5×0.8(P2 port) (For external pilot specification) 78.0 DIN rail length 125 3 88.5 125 107.5 150 4 99.0 125 118.0 150 5 109.5 150 128.5 175 6 120.0 150 139.0 175 7 130.5 175 149.5 175 30.5 (pitch) 8 141.0 175 160.0 200 9 151.5 200 170.5 200 16.5 10.5 10.5 14.8 10 162.0 200 181.0 225 11 172.5 200 191.5 225 12 183.0 225 202.0 250 13 193.5 225 212.5 250 14 204.0 250 223.0 250 15 214.5 250 233.5 275 16 225.0 275 244.0 275 17 235.5 275 254.5 300 18 246.0 275 265.0 300 19 256.5 300 275.5 325 20 267.0 300 286.0 325 Number of units 2 35 26 2 11 62.7 93 110 22 A B A B A B stn.1 stn.2 stn.3 stn.4 Block-off plate Quick fitting(φ4, φ6) 〔Can also select M5×0.8 female thread〕 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 (12.5) Number of units N 35 58 19 (B) 2 port (A) 4 port 20 13.5 11 (7.5) 1 34 62 F10M 25 5.5 27 10 20.5 (P) 1 port 3・( 5 R)port Dimensions of DIN rail mounting hole L1 DIN rail length Note 97.0 125 L2 Note Note: When using two piping blocks. F10MN Pilot specification (direct piping type) With valve output port different size fitting block S type plug connector L1(L2) 10.5 10.5 14.8 Manual override (pitch) A B A B A B 4 27 M5×0.8(P2 port) (For external pilot specification) 34 1 19 30 30.5 35 2 11 11 25.5 62.7 93 110 (A) 4 port (B) 2 port stn.1 stn.2 stn.3 stn.4 10 19 3・( 5 R)port (P) 1 port (7.5) 75.5 Block-off plate (12.5) 35 5.5 25 20.5 Dimensions of DIN rail mounting hole Note : The T0 type is 8mm shorter for the total valve length (the end cover protrusion is 8mm shorter). 578 Unit dimensions 78.0 DIN rail length 125 3 88.5 125 107.5 150 4 99.0 125 118.0 150 5 109.5 150 128.5 175 6 120.0 150 139.0 175 7 130.5 175 149.5 175 8 141.0 175 160.0 200 9 151.5 200 170.5 200 10 162.0 200 181.0 225 11 172.5 200 191.5 225 12 183.0 225 202.0 250 13 193.5 225 212.5 250 14 204.0 250 223.0 250 15 214.5 250 233.5 275 16 225.0 275 244.0 275 17 235.5 275 254.5 300 18 246.0 275 265.0 300 19 256.5 300 275.5 325 20 267.0 300 286.0 325 Number of units 2 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 22 Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 〔Can also select single size fitting〕 84 28.5 L1 DIN rail length Note 97.0 125 L2 Note Note: When using two piping blocks. F10 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) Combination of F10MPJ and F10-CONT F10M Number of units P J M Pilot specification (base piping type) Female thread specification (Scale1/4, Unit mm) With manifold output port different size fitting block Flat cable connector 10-pin specification M5×0.8(P2 port) (For external pilot specification) L1(L2) B 22 A 10.510.514.8 28.5 19 Manual override (pitch) 21 4 M5×0.8(P2 port) (For external pilot specification) 2-M5×0.8 3・5 (R)port stn.1 stn.2 stn.3 stn.4 Block-off plate Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 10 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 58 19 1 Dimensions of DIN rail mounting hole (7.5) 20.5 20 13.5 11 34 35 (63.5) 5.5 27 25 20 19 13.1 30.5 (12.5) ( 1 P)port 26 16.5 11 2 Applicable connector:10-pin 〔MIL-C-83503 conformity〕 2-Rc1/4 11.8 35 62.7 93 99 7 22 A B A B A B (P) 1 port 3・( 5 R)port ( 2 B)port ( 4 A)port Unit dimensions Number of units 2 99.0 DIN rail length 125 3 109.5 150 128.5 175 4 120.0 150 139.0 175 5 130.5 175 149.5 175 6 141.0 175 160.0 200 7 151.5 200 170.5 200 8 162.0 200 181.0 225 L1 DIN rail length Note 118.0 150 L2 Note F10M Number of units P J M SOLENOID VALVES F SERIES Note: When using two piping blocks. Pilot specification (base piping type) With manifold output port different size fitting block Flat cable connector 20-pin specification L1(L2) 10.510.514.8 28.5 19 Manual override (pitch) 21 4 M5×0.8(P2 port) (For external pilot specification) 22 A B A B A B 3 109.5 150 128.5 175 30.5 4 120.0 150 139.0 175 5 130.5 175 149.5 175 6 141.0 175 160.0 200 7 151.5 200 170.5 200 8 162.0 200 181.0 225 9 172.5 200 191.5 225 10 183.0 225 202.0 250 11 193.5 225 212.5 250 12 204.0 250 223.0 250 13 214.5 250 233.5 275 14 225.0 275 244.0 275 15 235.5 275 254.5 300 16 246.0 275 265.0 300 Number of units 2 35 Applicable connector:20-pin 〔MIL-C-83503 conformity〕 (12.5) stn.1 stn.2 stn.3 stn.4 Block-off plate Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 10 19 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 Dimensions of DIN rail mounting hole (P) 1 port 3・( 5 R)port 58 19 ( 2 B)port ( 4 A)port 20 13.5 11 34 1 20.5 (7.5) 35 (63.5) 5.5 27 25 26 2 11 62.7 93 99 99.0 DIN rail length 125 16.5 Unit dimensions L1 DIN rail length Note 118.0 150 L2 Note Note: When using two piping blocks. 579 F10 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) Combination of F10MPJ and F10-CONT F10M Number of units P J Pilot specification (base piping type) M With manifold output port different size fitting block Flat cable connector 26-pin specification L1(L2) 10.510.514.8 Manual override 19 (pitch) 21 Unit dimensions 28.5 4 M5×0.8(P2 port) (For external pilot specification) 16.5 2 Applicable connector:26-pin 〔MIL-C-83503 conformity〕 (12.5) stn.1 stn.2 stn.3 stn.4 Block-off plate Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 10 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 F10M Number of units P ( 2 B)port ( 4 A)port 58 19 1 Dimensions of DIN rail mounting hole (7.5) 20.5 20 13.5 11 34 35 (63.5) 5.5 27 25 26 11 30.5 35 62.7 93 99 22 A B A B A B Number of units 12 99.0 DIN rail length 125 13 109.5 150 128.5 175 14 120.0 150 139.0 175 15 130.5 175 149.5 175 16 141.0 175 160.0 200 17 151.5 200 170.5 200 18 162.0 200 181.0 225 19 172.5 200 191.5 225 10 183.0 225 202.0 250 11 193.5 225 212.5 250 12 204.0 250 223.0 250 13 214.5 250 233.5 275 14 225.0 275 244.0 275 15 235.5 275 254.5 300 16 246.0 275 265.0 300 17 256.5 300 275.5 325 18 267.0 300 286.0 325 19 277.5 325 296.5 325 20 288.0 325 307.0 350 L1 DIN rail length Note 118.0 150 L2 Note Note: When using two piping blocks. (P) 1 port 3・( 5 R)port J Pilot specification (base piping type) M With manifold output port different size fitting block D sub connector 25-pin specification L1(L2) Unit dimensions 10.510.514.8 28.5 (pitch) 21 4 M5×0.8(P2 port) (For external pilot specification) Number of units 12 99.0 DIN rail length 125 13 109.5 150 128.5 175 14 120.0 150 139.0 175 15 130.5 175 149.5 175 16 141.0 175 160.0 200 17 151.5 200 170.5 200 30.5 19 18 162.0 200 181.0 225 9 172.5 200 191.5 225 16.5 Manual override 10 183.0 225 202.0 250 11 193.5 225 212.5 250 12 204.0 250 223.0 250 13 214.5 250 233.5 275 14 225.0 275 244.0 275 15 235.5 275 254.5 300 16 246.0 275 265.0 300 17 256.5 300 275.5 325 18 267.0 300 286.0 325 19 277.5 325 296.5 325 20 288.0 325 307.0 350 35 D sub connector 〔MIL-C-24308 conformity〕 2-M2.6 (12.5) stn.1 stn.2 stn.3 stn.4 Block-off plate Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 19 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 13.5 11 (7.5) ( 2 B)port ( 4 A)port (P) 1 port 3・( 5 R)port 58 19 52 62 34 1 Dimensions of DIN rail mounting hole 20 5.5 35 20.5 580 10 27 25 26 2 11 62.7 99 93 22 A B A B A B L1 DIN rail length Note 118.0 150 L2 Note Note: When using two piping blocks. F10 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) F10M Combination of F10MPJ and F10-CONT J Pilot specification (base piping type) M P Number of units With manifold output port different size fitting block Terminal block type L1(L2) 10.510.514.8 28.5 19 (pitch) 42 M5×0.8(P2 port) (For external pilot specification) 4 Manual override 93 26 2 16.5 30.5 35 11 62.7 99 1 3 5 7 9 11 13 15 17 COM 2 4 6 8 10 12 14 16 18 22 A B A B A B M3 screw stn.1 stn.2 stn.3 stn.4 Block-off plate (12.5) Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 PL (P) 1 port 3・( 5 R)port 10.5 PUSH PUSH A LOCK PUSH A 14.8 58 175 149.5 175 141.0 175 160.0 200 5 151.5 200 170.5 200 6 162.0 200 181.0 225 7 172.5 200 191.5 225 8 183.0 225 202.0 250 9 193.5 225 212.5 250 10 204.0 250 223.0 250 11 214.5 250 233.5 275 12 225.0 275 244.0 275 13 235.5 275 254.5 300 14 246.0 275 265.0 300 15 256.5 300 275.5 325 16 267.0 300 286.0 325 17 277.5 325 296.5 325 18 288.0 325 307.0 350 28.5 PUSH A LOCK LOCK 93 91 LOCK LOCK B B PUSH 2 11 PUSH -J5:13.6 -J6:15.6 -J5□:23 -J6□:29 Applicable connector:20-pin 〔MIL-C-83503 conformity〕 stn.1 stn.2 stn.3 stn.4 stn.5 10 19 Single size fitting -J5:φ4 -J6:φ6 Single size fitting -J5□:φ8 -J6□:φ10 1 20.5 2(B)port 1(P)port 4(A)port 3・5(R)port 58 19 20 13.5 7.5 62 34 (63.5) 11.8 27 25 Unit dimensions 99.0 DIN rail length 125 3 109.5 150 128.5 175 4 120.0 150 139.0 175 5 130.5 175 149.5 175 6 141.0 175 160.0 200 7 151.5 200 170.5 200 8 162.0 200 181.0 225 9 172.5 200 191.5 225 10 183.0 225 202.0 250 11 193.5 225 212.5 250 12 204.0 250 223.0 250 13 214.5 250 233.5 275 14 225.0 275 244.0 275 15 235.5 275 254.5 300 16 246.0 275 265.0 300 Number of units 2 54.7 62.7 99 LOCK 5.5 130.5 4 10.5(pitch) 21 Manual override 35 3 Note L1(L2) 19 Dimensions of DIN rail mounting hole DIN rail length Note 139.0 175 L2 Pilot specification (base piping type) With manifold output port single size fitting block Flat cable connector 20-pin specification (12.5) 120.0 DIN rail length 150 L1 SOLENOID VALVES F SERIES Number of units ( 2 B)port ( 4 A)port Number of units 2 Note: When using two piping blocks. 30.5 F10M 1 Dimensions of DIN rail mounting hole (7.5) 20.5 20 13.5 11 34 19 69 35 27 5.5 25 10 Unit dimensions L1 DIN rail length Note 118.0 150 L2 Note Note: When using two piping blocks. 581 F10 Series Dimensions of Serial Transmission Compatible Manifold (Scale 1/3, Unit mm) ※For dimensions of the Manifold for Omron CompoBus / D, see p. 583. F10M Number of units S J Pilot specification (base piping type) M F10MSJ L1(L2) 10.510.514.8 28.5 (pitch) 4 With manifold output port different size fitting block 19 Manual override 21 M5×0.8(P2 port) (For external pilot specification) 22 A B A B A B 93 30.5 16.5 26 35 2 YS201L MADE IN JAPAN G 24V 0V 11 62.7 99 90 D ADDRESS 1 2 4 8 16 32 64128 G 24V 0V POWER SEND D 142160 Serial transmission block Note: Panel design differs depending on the transmission block specifications stn.1 stn.2 stn.3 stn.4 5 (12.5) 10 25 19 F10M Number of units S ( 2 B)port ( 4 A)port 58 19 1 (7.5) 20.5 Dimensions of DIN rail mounting hole 20 13.5 11 (63.5) 34 35 74.3 27 5.5 Quick fitting(φ4, φ6) 〔Can also select M5×0.8 female thread〕 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 Block-off plate 50 (P) 1 port 3・( 5 R)port F10MS Pilot specification (direct piping type) L1(L2) With valve output port different size fitting block 10.510.514.8 28.5 Manual override 19 21 (pitch) 4 M5×0.8(P2 port) (For external pilot specification) 3・( 5 R)port 22 A B A B A B (P) 1 Port Number of units 2 99.0 DIN rail length 200 3 109.5 200 128.5 225 4 120.0 225 139.0 225 5 130.5 225 149.5 250 6 141.0 225 160.0 250 7 151.5 250 170.5 275 8 162.0 250 181.0 275 9 172.5 275 191.5 275 10 183.0 275 202.0 300 11 193.5 300 212.5 300 12 204.0 300 223.0 325 13 214.5 300 233.5 325 14 225.0 325 244.0 350 15 235.5 325 254.5 350 16 246.0 350 265.0 350 Note Note: When using two piping blocks. 582 50 93 19 2 30 11 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 stn.1 stn.2 stn.3 stn.4 〔Can also select single size fitting〕 19 Block-off plate 10 84 (7.5) (63.5) 34 1 75.5 5 30.5 35 DIN rail length Note 118.0 200 L2 74.3 L1 ( 2 B)port Serial transmission block Note: Panel design differs depending on the transmission block specifications Unit dimensions 23.5 YS201L MADE IN JAPAN G 24V 0V 11 90 62.7 99 D ADDRESS 1 2 4 8 16 32 64128 G 24V 0V POWER SEND D 142160 ( 4 A)port F10 Series Dimensions of OMRON Corporation CompoBus/D Serial Transmission Compatible Manifold (Scale 1/3, Unit mm) F10M Number of units S J Pilot specification (base piping type) M L1(L2) With manifold output port different size fitting block 10.510.514.8 28.5 Manual override 19 (pitch) 21 M5×0.8(P2 port) (For external pilot specification) 4 A B A B A B 22 85 NS 30.5 35 62.7 50 MS 62 93 99 DRT1-OD16X REMOTE ADAPTER 24VDC 16.5 2 Serial transmission block Omron remote adaptor Model DRT1-OD16X stn.1 stn.2 stn.3 stn.4 Block-off plate 10 (12.5) 19 Quick fitting(φ4,φ6) 〔Can also select M5×0.8 female thread〕 Quick fitting(φ8,φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 58 19 20 13.5 11 (7.5) 1 Dimensions of DIN rail mounting hole 44.5 (63.5) 5.5 35 20.5 34 27 25 26 11 OUT (P) 1 port 3・( 5 R)port ( 2 B)port ( 4 A)port Number of units 2 99.0 DIN rail length 225 3 109.5 225 128.5 250 4 120.0 250 139.0 250 5 130.5 250 149.5 275 6 141.0 275 160.0 275 7 151.5 275 170.5 300 8 162.0 275 181.0 300 9 172.5 300 191.5 325 10 183.0 300 202.0 325 11 193.5 325 212.5 350 12 204.0 325 223.0 350 13 214.5 325 233.5 350 14 225.0 350 244.0 375 15 235.5 350 254.5 375 16 246.0 380 265.0 375 DIN rail length Note 118.0 250 L2 Note Additional Parts (Sold Separately) ●Muffler : KM-J10 [For both plug-in and non-plug-in type] ●(Scale 2/3, Unit mm) 73 A B A B 30 119 (58) φ18 Note:When using two piping blocks. φ10 L1 SOLENOID VALVES F SERIES Unit dimensions 583 584 SOLENOID VALVES SERIES INDEX 586 Dimensions of Single Valve Unit 590 Dimensions of Monoblock Manifold 593 Dimensions of PC Board Manifold 595 Dimensions of Split Manifold Non-Plug-in Type 596 Dimensions of Split Manifold Plug-in Type 597 Dimensions of Serial Transmission Compatible Manifold 600 SOLENOID VALVES F SERIES Specifications 585 F15 SERIES SPECIFICATIONS Specifications Basic Models and Functions Basic model Item F15T3 F15T4 F15T5 F15T1 F15T0 F15T2 Number of positions 3 positions 2 positions Number of ports For single solenoid only Valve function 5 For both single and double solenoid All port block, ABR connection, PAB connection Remark: For the optional specifications and order code, see p.532 ~ 556. Specifications Basic model Item F15T3 F15T4 F15T5 F15T0 F15T1 F15T2 F15T3G F15T4G F15T5G F15T0G F15T1G F15T2G External pilot type (for positive pressure) Internal pilot type Operation method mm2 Effective area〔CV〕Note1 Port size Note2 External pilot type (for vacuum) 10〔0.56〕 M5×0.8, Fitting for bothφ6 andφ8, Rc1/8 Fitting for bothφ6 andφ8, Rc1/8 Not required Lubrication 0.15∼0.7MPa{1.5∼7.1kgf/cm2} Main valve External pilot 0∼0.7MPa{0∼7.1kgf/cm2}Note3 0.15MPa∼−100kPa{1.5kgf/cm2∼−750.1mmHg} 0.2∼0.7MPa{2∼7.1kgf/cm2}Note3 0.2∼0.7MPa{2∼7.1kgf/cm2} MPa {kgf/cm2} Proof pressure Response time Note4 ms ON/OFF time F15T3V Air Media Operating pressure range F15T0V F15T1V F15T2V 1.05{10.7} DC12V, DC24V Max.20/30 Max.15/50 Max.20/30 Max.15/50 Max.20/30 Max.15/50 AC100V Max.20/30 Max.15/50 Max.20/30 Max.15/50 Max.20/30 Max.15/50 Hz Maximum operating frequency Minimum time to energize for self holding Note5 ms 5 50 50 2 m/s{G} Shock resistance 50 5∼50 Operating temperature range (atmosphere and media) ℃ 1373 {140.0} (Axial direction 294.2 {30.0}) 294.2 {30.0} 1373 {140.0} (Axial direction 294.2 {30.0}) 294.2 {30.0} 1373 {140.0} (Axial direction 294.2 {30.0}) 294.2 {30.0} Any Mounting direction Notes: 1. 2. 3. 4. For details, see the effective area on p.587. For details, see the port size on p.587. When the main valve pressure is 0.2~0.7MPa, set the external pilot pressure to the main valve pressure or higher, and to 0.7MPa or less. Values when air pressure is 0.5MPa. For switching phase timing, add a maximum of 5 ms to the response time of AC specification. The values for 2-position valves are when used as a single solenoid, and the values for 3-position valves are those switching from the neutral state of all port block. 5. When used as a double solenoid valve. Excludes T0. Remark: Conversion to psi., 1Mpa=145psi., 1kgf/cm2=14.2psi., e.g. 0.15Mpa=21.8psi. Solenoid Specifications Rated voltage Item Voltage range V Rated frequency Current DC24V DC12V 10.8∼13.2 21.6∼26.4 90∼110 (12±10%) (24±10%) (100±10%) Hz mA(r.m.s) Starting (When rated voltage is applied) Power consumption Allowable leakage current Color of LED indicator Note3 Surge suppression (as standard) 60 10Note 1 10Note 1 10Note 1 76 38 W 0.9 0.9 1.0VA mA 4.0 2.0 2.0 Type B Min. 100 MΩ SA:Red, SB:Green SA:Red, SB:Green Flywheel diode Notes: 1. Since the AC types have built-in bridge diodes, the starting current and energizing current value are virtually the same. 2. Value at DC500V megger. 3. The indicator color for T0 is red only. 586 50 10Note 1 Energizing Type of insulation Insulation resistance Note 2 AC100V SA:Red, SB:Green Bridge diode Cylinder Operating Speed Flow Rate How to obtain the cylinder speed Maximum operating speed Cylinder stops Cushion impact Cylinder starts Time 1000 800 φ40 φ50 600 400 φ63 φ80 200 0 0.4 0.3 0.2 0.1 0 0.7 0.6 0.5 0.4 0.3 0.2 0.1 200 400 600 800 1000 Flow rate R/min (ANR) How to read the graph If supply pressure is 0.5MPa and flow rate is 500R/min (ANR), the valve output pressure becomes 0.4MPa. Delay time Delay time 0.5 MPa % Measuring conditions 0.5MPa 0.6 10 20 30 40 50 60 70 Load ratio ●Air pressure:0.5MPa{5.1kgf/cm2} ●Piping (outer diameter×inner diameter× length):φ8×φ6×1000mm ●Fitting:Quick fitting TS8-01 Load ●Load ratio= (%) Cylinder theoretical thrust ●Cylinder stroke:150mm Load Valve output pressure t3 t2 Maximum operating speed Cylinder stroke Solenoid valve energized t1 Supply pressure MPa 0.7 mm/s 1200 s 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 φ80 φ63 φ50 φ40 10 20 30 40 50 60 70 % Load ratio Note: Delay time may vary according to the cylinder stroke. Port Size Description/Piping specification PR P2 A, B P, R With sub-base M5×0.8 M5×0.8 Rc1/8 Rc1/8 With female thread block ― ― Rc1/8 Rc1/8 With different size fitting block ― ― For both φ6 andφ8 Rc1/8 With single size fitting block ― ― φ6 or φ8 Rc1/8 Monoblock type with female thread block, or PC board type with female thread block M5×0.8 M5×0.8 Rc1/8 Rc1/4 Monoblock type with fitting block, or PC board type with fitting block M5×0.8 M5×0.8 For both φ6 and φ8 Rc1/4 Monoblock type with single size fitting block, or PC board type with single size fitting block M5×0.8 M5×0.8 φ6 or φ8 Rc1/4 Split type with female thread block, or serial transmission type with female thread block ― M5×0.8 Rc1/8 Rc1/4 Split type with fitting block, or serial transmission type with fitting block ― M5×0.8 For both φ6 and φ8 For both φ8 and φ10 Split type with single size fitting block, or serial transmission type with single size fitting block ― M5×0.8 φ6 or φ8 φ8, φ10 Effective Area 〔Cv〕 ●When using as a single unit Basic model F15T0□-F5 F15T1□-F5 F15T2□-F5 F15T3□-F5 F15T4□-F5 F15T5□-F5 F15T0□-F6 F15T1□-F6 F15T2□-F6 F15T3□-F6 F15T4□-F6 F15T5□-F6 mm2 ●When mounted on a manifold Manifold model Effective area 〔Cv〕 Valve Type 8.0〔0.44〕 8.5〔0.47〕 F15T0□ F15T1□ F15T2□ F15T3□ F15T4□ F15T5□ Output port Fitting for both φ6 andφ8 Female thread Output port φ6 fitting Output port φ8 fitting mm2 F15M□F F15M□A F15M□N 9.2〔0.51〕 8.5〔0.47〕 10.0〔0.56〕 7.7〔0.43〕 7.2〔0.40〕 8.7〔0.48〕 8.2〔0.45〕 8.0〔0.44〕 9.7〔0.54〕 Caution: When you use the individual air supply spacer or the individual air exhaust spacer, effective area decreases about 30%. 587 SOLENOID VALVES F SERIES Manifold Single unit ●F15 Series Mass Single Valve Unit Mass g F15T□□-FJ F15T□□ F15T□□-A1 F15T□□-A2 Output section Output section Output section Output section Output section Output section None With plate With plate With different size fitting block With φ6 fitting block With φ8 fitting block Input section Input section Input section Input section Input section Input section None None With A type sub-base None None None 87 106 216 117 123 133 F15T□□-FM F15T□□-F3 F15T□□-F4 F15T□□-F5 F15T□□-F6 Output section Output section F15T□□-FJ6 F15T□□-FJ5 g Output section With female thread block With different size fitting block With female thread block Output section Output section With φ6 fitting block With φ8 fitting block Input section Input section Input section Input section Input section None With female thread block With female thread block With female thread block With female thread block 108 132 123 138 148 Basic Type F15T0 is 12g less than the mass shown above. Monoblock Manifold Mass (included single valve unit) g Mass calculation of each unit Monoblock manifold A, B port output specifications Female thread Different size fitting block φ6 fitting block φ8 fitting block A type (224×n)+100 (234×n)+100 (240×n)+100 (250×n)+100 F type (155×n)+105 (165×n)+105 (171×n)+105 (181×n)+105 Calculation example : F15M8AM stn.1∼stn.8 F15T1-A1-PS DC24V (224×8)+100=1892g When mounting a block-off plate, calculate the female thread specifications at 90g less than the above calculation results per unit, while the differing size fitting specifications are 100g, φ6 fitting specifications 106g, and the φ8 fitting specifications 116g less. When mounting the F15T0 specifications, subtract 12g per unit from the above calculation results. PC Board Manifold Mass (included single valve unit) g Mass calculation of each unit A, B port output specifications PC board manifold Circuit board and Female thread Different size fitting block φ6 fitting block φ8 fitting block A type (224×n)+100 (234×n)+100 (240×n)+100 (250×n)+100 F type (155×n)+105 (165×n)+105 (171×n)+105 (181×n)+105 connector section (2×n)+15 Calculation example : F15M8APM-F201-W stn.1∼stn.8 F15T1-A1-PP DC24V (224×8)+100+(2×8)+15=1923g When mounting a block-off plate, calculate the female thread specifications at 90g less than the above calculation results per unit, while the differing size fitting specifications are 100g, φ6 fitting specifications 106g, and the φ8 fitting specifications 116g less. When mounting the F15T0 specifications, subtract 12g per unit from the above calculation results. 588 Mass Mass of Split Manifold and Serial Transmission Compatible Type The split manifold has the same mass as that for the combination of valve output and manifold output specifications. The mass can only change with selection of the type of input/output block. Mass of Split Manifold Non-Plug-in Type (included single valve unit) g Mass calculation of each unit Non-plug-in type A, B port output specifications Female thread Different size fitting block φ6 fitting block φ8 fitting block (166×n)+254 (176×n)+254 (182×n)+254 (192×n)+254 g Additional mass Piping block specification Female thread Different size fitting block φ8 fitting block φ10 fitting block 150 160 185 194 Calculation example : F15M8N-MR stn.1∼stn.8 F15T1-A1-PS DC24V (166×8)+254+150=1732g When mounting a block-off plate, calculate the female thread specifications at 90g less than the above calculation results per unit, while the differing size fitting specifications are 100g, φ6 fitting specifications 106g, and the φ8 fitting specifications 116g less. When mounting the F15T0 specifications, subtract 12g per unit from the above calculation results. Mass of Split Manifold Plug-in Type/ Serial Transmission Compatible Type(included single valve unit) g Mass calculation of each unit Plug-in type Serial transmission compatible type A, B port output specifications Female thread Different size fitting block φ6 fitting block φ8 fitting block (168×n)+254 (176×n)+254 (182×n)+254 (192×n)+254 g Additional mass Different size fitting block φ8 fitting block φ10 fitting block 150 160 185 194 g Additional mass Wiring block specification -F100, -F101 -F200, -F201, -F260 -D250, -D251 -T200 68 70 70 150 g Transmission block mass Serial transmission blockNote YS□□ YS391 160 110 Calculation example : F15M8PM-MR-F201 DC24V stn.1∼stn.8 F15T1-A1 DC24V (168×8)+254+150+70=1818g When mounting a block-off plate, calculate the female thread specifications at 90g less than the above calculation results per unit, while the differing size fitting specifications are 100g, φ6 fitting specifications 106g, and the φ8 fitting specifications 116g less. When mounting the F15T0 specifications, subtract 12g per unit from the above calculation results. Note : For the serial transmission compatible manifold, add to the calculation the wiring block -F201(70g). 589 SOLENOID VALVES F SERIES Piping block specification Female thread F15 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F15T F15T Valve specification -F3-PS With output port different size fitting block With input port female thread block S type plug connector ※For T0 type dimensions, see p.591. (66.5) 16 57 27 10 6 A B Manual override ( 4 A)port 15.5 19 (R2) 3 Quick fitting (φ6,φ8) 34.3 46 75.5 42 (P) 1 14.5 14.5 ( 5 R1) 15.5 15 130.5 2-φ3.4 (Mounting hole) 83.2 3-Rc1/8 2 ( 2 B)port 30 1 Mounting bracket(F15Z-21)Note 2-φ3.4 (Mounting hole) Note: The mounting bracket is additional part (sold separately). 3 16 10 φ15 1.6 1 6 11 F15T Valve specification -F4-PS With output port female thread block With input port female thread block S type plug connector ※For T0 type dimensions, see p.591. (46.5) 16 37 10 27 6 A B Manual override (A)port 4 3-Rc1/8 2-Rc1/8 83.2 15.5 19 34.3 46 75.5 42 (P) 1 ( 3 R2) 14.5 14.5 ( 5 R1) 15.5 15 130.5 2-φ3.4 (Mounting hole) 2 2 (B)port 30 1 Mounting bracket(F15Z-21)Note 2-φ3.4 (Mounting hole) 16 3 10 1.6 1 Note: The mounting bracket is additional part (sold separately). 6 11 590 F15 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F15T0-F□-PS -F5: (59) -F6: (66.5) With output port single size fitting block With input port female thread block S type plug connector -F5:49.5 -F6:57 (300) 16 10 27 15 6 Manual override (PR) 5 (R1)port 3-Rc1/8 PUSH LOCK 73.2 9 12 1 Single size fitting -F5:φ6 -F6:φ8 30 10 6 11 Note: The mounting bracket is additional part (sold separately). SOLENOID VALVES F SERIES 16 1.6 2-φ3.4 (Mounting hole) 3 1 4 (A)port 2 (B)port 24.3 15.5 46 65.5 32 14.5 14.5 3 (R2)port 2-φ3.4 (Mounting hole) 15.5 15 120.5 1 (P)port 591 F15 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F15T F15T Valve specification Operation method -A2-PS With A type sub-base S type plug connector 10 27 A B Manual override M5×0.8 2-φ3.4 (Mounting hole) 15 26 15 PR 5 (R1) ●For double solenoid ●or 3-position valve B side manual override 13 11 6 (R2) 3 83.2 75.5 50 9 62 23.5 15 12 2 (B) 4 (A) 2-Rc1/8 (P) 1 P2 130.5 3-Rc1/8 31 M5×0.8 7.5 (For external pilot specification) 30 17 25 15 9 3.5 32 (57.5) 17 30 20 Note : The T0 type is 10mm shorter for the total valve length (the end cover protrusion is 10mm shorter). Option Made to Order ●L type plug connector : -PL ●Manual lever override (Scale 2/3, Unit mm) 43.5 3 A B 3 (R2) 2 (B) Note : The T0 type is 10mm shorter for the total valve length (the end cover protrusion is 10mm shorter). 592 36.3 (R1) 5 ( 1 P) 4 (A) PR P2 119.5 A B F15 Series Dimensions of Monoblock Manifold A Type (Scale 1/3, Unit mm) F15M J AM Number of units F15MA Pilot specification (base piping type) L Monoblock manifold A type With manifold output port different size fitting block S type plug connector 16 16 16 16 (pitch) Manual override ●Internal pilot specification 2-M5×0.8(Both sides) A B A B A B 38 4-φ4.5 130.5 P 48 40 3 64 56 4 80 72 5 96 88 6 112 104 7 128 120 8 144 136 9 160 152 10 176 168 11 192 184 Brock-off plate 12 208 200 Quick fitting (φ6, φ8) 〔Can also select Rc1/8 female thread〕 13 224 216 14 240 232 15 256 248 16 272 264 17 288 280 18 304 296 19 320 312 20 336 328 64 30 13 10.5 20 20 83.2 20 54.5 10 L 2 6-Rc1/4(Both sides) 4 ●External pilot specification P 2-M5×0.8(Both sides) 15.3 15.5 32 (78.5) 46 20 20 10 P2 PR (R1) 5 (P) 1 (R2) 3 54.5 2 B)port ( 9 3.5 2-M5×0.8(Both sides) 4 stn.1 stn.2 stn.3 stn.4 15 38 23 Unit dimensions Number of units (R2) 3 20 PR (R1) 5 (P) 1 150 23 4 A)port ( F15M AL Number of units Pilot specification (base piping type) Monoblock manifold A type With manifold output port single size fitting block S type plug connector 2-M5 (PR) (Both sides) L 16(pitch) 38 16 16 Manual override 23 Unit dimensions 5 (R1)port 3 (R2)port PUSH PUSH A 4-φ4.5 (Mounting hole) PUSH A LOCK LOCK 4 2 (B)port 4 (A)port 64 B PUSH P stn.1 stn.2 stn.3 stn.4 stn.5 (4) -J5:22.5 -J6:30 6-Rc1/4 (Both sides) LOCK B 10.5 13 LOCK PUSH 20 20 73.2 P 48 40 3 64 56 4 80 72 5 96 88 6 112 104 7 128 120 8 144 136 9 160 152 10 176 168 11 192 184 12 208 200 13 224 216 14 240 232 15 256 (78.5) 46 32 15 248 16 272 264 17 288 Single size fitting -J5:φ6 -J6:φ8 280 18 304 296 19 320 312 20 336 328 15.3 15.5 83.2 120.5 LOCK PUSH A 130.5 -J5:142.5 -J6:150 10 54.5 20 LOCK 20 L 2 Number of units 1 (P)port 593 SOLENOID VALVES F SERIES 6-Rc1/4(Both sides) F15 Series Dimensions of Monoblock Manifold F Type (Scale 1/3, Unit mm) F15M F15MF F (direct piping type) Number of units Monoblock manifold F type With valve output port different size fitting block S type plug connector L 23 16 16 23 (pitch) Manual override Unit dimensions A B 4-φ4.5 61 19 18 15.5 14 34.3 13 130.5 83.2 18 11 24 P 11 Block-off plate 30 (87.5) stn.1 stn.2 stn.3 stn.4 15 Quick fitting(φ6, φ8) 〔Can also select Rc1/8 female thread〕 〔Can also select single size fitting〕 57 18 28 (R2) 3 (P) 1 20 Note : The T0 type is 10mm shorter for the total valve length (the end cover protrusion is 10mm shorter). 594 L P 2 62 40 3 78 56 4 94 72 5 110 88 6 126 104 7 142 120 8 158 136 9 174 152 10 190 168 11 206 184 12 222 200 13 238 216 14 254 232 15 270 248 16 286 264 17 302 280 18 318 296 19 334 312 20 350 328 Number of units ( 2 B)port 11 6-Rc1/4 (Both sides) A B ( 4 A)port (R1) 5 PR 27 2-M5×0.8 (Both sides) A B F15 Series Dimensions of PC Board Manifold A Type, F Type (Scale 1/3, Unit mm) F15M J AP M Number of units Note: The mounted valve example has -W wiring connection specification. Note: In wiring connection specification -S, the mounted valves are T0 or T1 type. PC board manifold A type With manifold output port different size fitting block 2-M5×0.8(Both sides) ●Internal pilot specification Power supply connection terminal 38 46 (78.5) Note: The position of the groove preventing wrong insertions of -F200 is reversed to that of -F201. Illustration shows the -F201 case. 32 20 54.5 PR ( 5 R1)(P) 1 (R2) 3 20 Applicable connector:20-pinNote 〔MIL-C-83503 conformity〕 D 23 10 F15MAPJ Pilot specification (base piping type) 15 6-Rc1/4 (Both sides) stn.1 stn.2 stn.3 stn.4 stn.5 stn.6 L ●External pilot specification 38 16 16 23 9 16 16 (pitch) Manual override A B A B A B A B A B 4-φ4.5 6-Rc1/4(Both sides) 15.3 15.5 4 P 4 D L P 6 112 104 63 Number of units 8 144 136 68.5 10 176 168 68.5 12 208 200 79.5 14 240 232 90 16 272 264 90 Note: Wiring connection specifications For -S: 6, 8,10,12,14,16 units For -W: 6, 8 units 2 B)port ( 4 A)port ( F15M Quick fitting(φ6, φ8) 〔Can also select Rc1/8 female thread〕 Unit dimensions FP (direct piping type) Number of units Power supply connection terminal F15MFP Applicable connector:20-pinNote 〔MIL-C-83503 conformity〕 D PC board manifold F type With valve output port different size fitting block (87.5) Note: The mounted valve example has -W wiring connection specification. Note: In wiring connection specification -S, the mounted valves are T0 or T1 type. 57 30 Note: The position of the groove preventing wrong insertions of -F200 is reversed to that of -F201. Illustration shows the -F201 case. 15 stn.1 stn.2 stn.3 stn.4 stn.5 stn.6 L 23 16 16 23 (pitch) Manual override 2-M5×0.8 (Both sides) A B A B A B A B Quick fitting(φ6, φ8) 〔Can also select Rc1/8 female thread〕 〔Can also select single size fitting〕 A B 4-φ4.5 24 10 61 18 19 13 14 15.5 34.3 130.5 27 ( 2 B)port 83.2 18 18 20 ( 3 R2) (P) 1 28 (R1) 5 96 PR 11 6-Rc1/4 (Both sides) Unit dimensions 11 P 11 Note : The T0 type is 10mm shorter for the total valve length (the end cover protrusion is 10mm shorter). D L P 6 126 104 70 Number of units ( 4 A)port 8 158 136 75.5 10 190 168 75.5 12 222 200 86.5 14 254 232 92 16 286 264 92 Note: Wiring connection specifications For -S: 6, 8,10,12,14,16 units For -W: 6, 8 units 595 SOLENOID VALVES F SERIES 10 20 30 13 10.5 20 64 130.5 83.2 150 20 10 20 54.5 P2 ( 5 R1)(P) 1 (R2) 3 99 PR 3.5 4-M5×0.8 (Both sides) F15 Series Dimensions of Split Manifold Non-Plug-in Type (Scale 1/3, Unit mm) F15M Number of units N F15MNJ J Pilot specification (base piping type) M With manifold output port different size fitting block S type plug connector L1(L2) 16 16 17.5 (pitch) 34.5 M5×0.8(P2 port) (For external pilot specification) Manual override A B Unit dimensions A B 105 35 130.5 Quick fitting (φ6, φ8) 〔Can also select Rc1/8 female thread〕 15 26 25 13 10 44.6 83.2 Block-off plate stn.1 stn.2 stn.3 stn.4 19 Quick fitting (φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 25 F15M 35 67 19 20 18.3 15.5 (7.5) (3) 46 81 5.5 32 (12.5) ( 2 B)port Number of units 20.5 (P) 1 port ( 4 A)port N 101 DIN rail length 150 120 DIN rail length Note 150 3 117 150 136 175 4 133 175 152 200 5 149 175 168 200 6 165 200 184 225 7 181 225 200 250 8 197 225 216 250 9 213 250 232 275 10 229 275 248 275 11 245 275 264 300 12 261 300 280 325 13 277 325 296 325 14 293 325 312 350 15 309 350 328 375 16 325 375 344 375 17 341 375 360 400 18 357 400 376 425 19 373 400 392 425 20 389 425 408 450 Number of units 2 35 A B Dimensions of DIN rail mounting hole L1 L2 Note Note: When using two piping blocks. 3・( 5 R)port F15MN Pilot specification (direct piping type) With valve output port different size fitting block S type plug connector L1(L2) 16 16 17.5 (pitch) 34.5 M5×0.8(P2 port) (For external pilot specification) Manual override A B A B Unit dimensions A B 3・5(R)port 120 3 117 150 136 175 4 133 175 152 200 5 149 175 168 200 6 165 200 184 225 7 181 225 200 250 8 197 225 216 250 9 213 250 232 275 10 229 275 248 275 11 245 275 264 300 12 261 300 280 325 13 277 325 296 325 14 293 325 312 350 15 309 350 328 375 16 325 375 344 375 17 341 375 360 400 18 357 400 376 425 20.5 19 373 400 392 425 Dimensions of DIN rail mounting hole 20 389 425 408 450 35 44.6 19 24.2 15.5 10 13 34.3 83.2 101 DIN rail length Note 150 105 ( 1 P)port 130.5 ( 2 B)port DIN rail length 150 Number of units 2 35 ( 4 A)port Quick fitting (φ6, φ8) 〔Can also select Rc1/8 female thread〕 〔Can also select single size fitting〕 stn.1 stn.2 stn.3 stn.4 15 19 Quick fitting (φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 Block-off plate (12.5) (3) 596 (7.5) 46 35 93 106 5.5 57 25 L1 L2 Note Note: When using two piping blocks. Note : The T0 type is 10mm shorter for the total valve length (the end cover protrusion is 10mm shorter). F15 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) Combination of F15MPJ and F15-CONT P Number of units With manifold output port different size fitting block Flat cable connector 10-pin specification Female thread specification (Scale1/4, Unit mm) M5×0.8(P2 port) (For external pilot specification) L1(L2) 16 25 Manual override 21 16 17.5 (pitch) 34.5 M5×0.8(P2 port) (For external pilot specification) A B 35 F15M J M Pilot specification (base piping type) P2 A B A B 7 105 35 119.5 5 35 A B 2-Rc1/4 20 19 18.3 15.5 Applicable connector:10-pin 〔MIL-C-83503 conformity〕 26 25 13 10 44.6 83.2 2-Rc1/8 ( 1 P)port 3・5 (R)port Block-off plate stn.1 stn.2 stn.3 stn.4 (12.5) Quick fitting(φ6, φ8) 〔Can also select Rc1/8 female thread〕 15 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 (3) (7.5) Dimensions of DIN rail mounting hole ( 2 B)port 67 19 20 18.3 15.5 46 81 20.5 (77.5) 35 32 5.5 25 (P) 1 port 3・( 5 R) port ( 4 A)port Unit dimensions 122 DIN rail length 150 141 DIN rail length Note 175 138 175 157 200 4 154 200 173 200 5 170 200 189 225 6 186 225 205 250 7 202 250 221 250 8 218 250 237 275 Number of units 2 3 L1 L2 Note Note: When using two piping blocks. Number of units P J Pilot specification (base piping type) M With manifold output port different size fitting block Flat cable connector 20-pin specification SOLENOID VALVES F SERIES F15M L1(L2) 16 25 21 16 17.5 (pitch) 34.5 M5×0.8(P2 port) (For external pilot specification) Manual override A B A B 105 26 25 13 10 Applicable connector:20-pin 〔MIL-C-83503 comformity〕 stn.1 stn.2 stn.3 stn.4 Quick fitting(φ6, φ8) 〔Can also select Rc1/8 female thread〕 (12.5) Block-off plate 19 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 (3) Dimensions of DIN rail mounting hole (7.5) 20.5 ( 2 B)port ( 4 A)port (P) 1 port 67 19 20 18.3 15.5 46 81 35 (77.5) 5.5 32 25 15 Unit dimensions 122 DIN rail length 150 141 DIN rail lengthNote 175 3 138 175 157 200 4 154 200 173 200 5 170 200 189 225 6 186 225 205 250 7 202 250 221 250 8 218 250 237 275 9 234 275 253 300 10 250 300 269 300 11 266 300 285 325 12 282 325 301 350 13 298 325 317 350 14 314 350 333 375 15 330 375 349 375 16 346 375 365 400 Number of units 2 44.6 83.2 35 119.5 35 A B L1 L2 Note Note: When using two piping blocks. 3・( 5 R)port 597 F15 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) Combination of F15MPJ and F15-CONT F15M Number of units P J Pilot specification (base piping type) M With manifold output port different size fitting block Flat cable connector 26-pin specification L1(L2) 16 25 21 16 17.5 (pitch) 34.5 M5×0.8(P2 port) (For external pilot specification) Manual override A B A B Unit dimensions 35 A B 105 35 119.5 26 25 13 10 44.6 83.2 Applicable connector:26-pin 〔MIL-C-83503 conformity〕 stn.1 stn.2 stn.3 stn.4 Quick fitting(φ6, φ8) 〔Can also select Rc1/8 female thread〕 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 (3) Dimensions of DIN rail mounting hole Number of units P ( 2 B)port 67 19 20 18.3 15.5 46 81 (77.5) 5.5 35 20.5 F15M 15 Block-off plate 32 25 (7.5) (12.5) ( 4 A)port 21 34.5 200 173 200 5 170 200 189 225 6 186 225 205 250 7 202 250 221 250 8 218 250 237 275 9 234 275 253 300 10 250 300 269 300 11 266 300 285 325 12 282 325 301 350 13 298 325 317 350 14 314 350 333 375 15 330 375 349 375 16 346 375 365 400 17 362 400 381 425 18 378 425 397 425 19 394 425 413 450 20 410 450 429 475 Unit dimensions 105 35 119.5 26 25 13 10 44.6 83.2 stn.1 stn.2 stn.3 stn.4 15 Block-off plate 19 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 32 Quick fitting(φ6, φ8) 〔Can also select Rc1/8 female thread〕 ( 4 A)port (P) 1 port 3・( 5 R)port 20 67 18.3 15.5 66 (7.5) 46 (3) ( 2 B)port 19 81 5.5 200 154 A B 2-M2.6 35 157 4 M5×0.8(P2 port) (For external pilot specification) 35 A B 16 17.5 (pitch) D sub connector 〔MIL-C-24308 conformity〕 598 175 L1(L2) A B Dimensions of DIN rail mounting hole 138 Note J Pilot specification (base piping type) M 25 Manual override 20.5 3 L2 3・( 5 R)port 16 25 141 DIN rail length Note 175 L1 Note: When using two piping blocks. (P) 1 port With manifold output port different size fitting block D sub connector 25-pin specification (12.5) 122 DIN rail length 150 Number of units 2 122 DIN rail length 150 141 DIN rail lengthNote 175 3 138 175 157 200 4 154 200 173 200 5 170 200 189 225 6 186 225 205 250 7 202 250 221 250 8 218 250 237 275 9 234 275 253 300 10 250 300 269 300 11 266 300 285 325 12 282 325 301 350 13 298 325 317 350 14 314 350 333 375 15 330 375 349 375 16 346 375 365 400 17 362 400 381 425 18 378 425 397 425 19 394 425 413 450 20 410 450 429 475 Number of units 2 L1 L2 Note Note: When using two piping blocks. F15 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) F15M P Number of units Combination of F15MPJ and F15-CONT J Pilot specification (base piping type) M With manifold output port different size fitting block Terminal block type L1 (L2) 16 25 42 16 17.5 (pitch) M5×0.8 (P2 port) (For external pilot specification) 34.5 Manual override A B A B 35 A B 105 35 26 44.6 25 10 13 83.2 119.5 1 3 5 7 9 11 13 15 17 COM 2 4 6 8 10 12 14 16 18 Unit dimensions M3 screw stn.1 stn.2 stn.3 stn.4 Quick fitting (φ6, φ8) [Can also select Rc1/8 female thread] Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 32 (12.5) 15 Block-off plate Number of units 17.5 16 PUSH PUSH A PUSH A 67 20 105 44.6 73.2 83.2 225 210 250 6 207 250 226 275 7 223 250 242 275 8 239 275 258 300 9 255 300 274 300 10 271 300 290 325 11 287 325 306 350 12 303 350 322 350 13 319 350 338 375 14 335 375 354 400 15 351 400 370 400 16 367 400 386 425 17 383 425 402 450 18 399 425 418 450 Unit dimensions LOCK B -J5: 17.5 -J6: 25 stn.1 stn.2 stn.3 stn.4 stn.5 15 19 Single size fitting -J5: φ6 -J6: φ8 Single size fitting -J5□: φ8 -J6□: φ10 DIN rail mounting hole dimensions 2 (B) port 4 (A) port 141 DIN rail lengthNote 175 3 138 175 157 200 4 154 200 173 200 5 170 200 189 225 6 186 225 205 250 7 202 250 221 250 8 218 250 237 275 9 234 275 253 300 10 250 300 269 300 11 266 300 285 325 12 282 325 301 350 13 298 325 317 350 14 314 350 333 375 15 330 375 349 375 16 346 375 365 400 L1 L2 Note 67 Note: When using two piping blocks. 20 18.3 7.5 19 (77.5) 15.5 32 25 122 DIN rail length 150 Number of units 2 PUSH 10 13 PUSH 〔MIL-C-83503 conformity〕 46 191 PUSH LOCK Applicable connector:20-pin 3 225 5 A LOCK B 81 194 34.5 109.5 LOCK LOCK 5.5 225 16 (pitch) 21 LOCK 35 225 175 L1 (L2) 25 20.5 178 4 Pilot specification (base piping type) Manual override 119.5 19 18.3 15.5 4 (A) port With manifold output port single size fitting block Flat cable connector 20-pin specification (12.5) 200 Note 1 (P) port 3・5 (R) port 2 (B) port PL 159 3 L2 SOLENOID VALVES F SERIES F15M 162 DIN rail lengthNote 200 L1 Note: When using two piping blocks. -J5□: 23 -J6□: 29 (3) 20.5 Dimensions of DIN rail mounting hole (7.5) 35 46 5.5 83 25 143 DIN rail length 175 Number of units 2 1 (P) port 3・5 (R) port 599 F15 Series Dimensions of Serial Transmission Compatible Manifold (Scale 1/3, Unit mm) ※For dimensions of manifold for Omron CompoBus / D, see p. 601. F15M Number of units S J Pilot specification (base piping type) M F15MSJ L1 (L2) 16 With manifold output port different size fitting block 25 16 17.5 (pitch) 21 34.5 M5×0.8 (P2 port) (For external pilot specification) Manual override A B A B 35 A B 105 44.6 25 26 35 10 13 YS201L MADE IN JAPAN G 24V 0V 83.2 119.5 90 D ADDRESS 1 2 4 8 16 32 64128 G 24V 0V POWER SEND D 142160 Serial transmission block Note: Panel design differs depending on the transmission block specifications Quick fitting (φ6, φ8) [Can also select Rc1/8 female thread] 5 50 (12.5) Block-off plate 15 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 20.5 (3) F15M Number of units (7.5) Dimensions of DIN rail mounting hole 67 19 20 46 18.3 15.5 74.3 81 35 (77.5) 5.5 32 25 1 (P) port 2 (B) port 3・5 (R) port 4 (A) port S (direct piping type) F15MS L1 (L2) With valve output port different size fitting block 16 25 21 16 17.5 (pitch) Manual override A B A B 34.5 M5×0.8 (P2 port) (For external pilot specification) A B 35 3・5 (R) port 1 (P) port 4 154 250 173 275 5 170 275 189 275 6 186 275 205 300 7 202 300 221 325 8 218 300 237 325 9 234 325 253 350 10 250 350 269 375 11 266 350 285 375 12 282 375 301 400 13 298 400 317 400 14 314 400 333 425 15 330 425 349 450 16 346 450 365 450 Note: When using two piping blocks. 600 105 10 44.6 19 15.5 19 Block-off plate 5 50 93 250 Quick fitting(φ6, φ8) Quick fitting(φ8, φ10) 〔Can also select Rc1/8 female thread〕 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 〔Can also select single size fitting〕 2 (B) port 57 157 46 225 4 (A) port 15 (3) 138 Note (7.5) 141 DIN rail length Note 225 L2 74.3 122 DIN rail length 225 L1 106 3 Serial transmission block Note: Panel design differs depending on the transmission block specifications (77.5) Number of units 2 24.2 34.3 35 13 YS201L MADE IN JAPAN G 24V 0V 83.2 90 119.5 D ADDRESS 1 2 4 8 16 32 64128 G 24V 0V POWER SEND D 142160 Unit dimensions F15 Series Dimensions of OMRON Corporation CompoBus/D Serial Transmission Compatible Manifold (Scale 1/3, Unit mm) F15M Number of units S J Pilot specification (base piping type) M With manifold output port different size fitting block L1 (L2) 16 25 16 17.5 (pitch) 21 34.5 M5×0.8 (P2 port) (For external pilot specification) Manual override A B A B A B 35 85 DRT1-OD16X 105 NS 35 25 13 10 44.6 OUT 26 119.5 MS 83.2 62 50 REMOTE ADAPTER 24VDC Serial transmission block Omron remote adaptor Model DRT1-OD16X Quick fitting (φ6, φ8) [Can also select Rc1/8 female thread] Block-off plate 15 (12.5) Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 19 275 173 300 5 170 300 189 325 6 186 325 205 350 7 202 325 221 350 8 218 350 237 375 9 234 375 253 375 10 250 375 269 400 11 266 400 285 425 12 282 425 301 425 13 298 425 317 450 14 314 450 333 475 15 330 450 349 475 16 346 475 365 475 67 19 Additional Parts (Sold Separately) ●Muffler : KM-J10 [For both plug-in and non-plug-in type] ●(Scale 2/3, Unit mm) 73 A B A B 30 131 300 154 ●Muffler : KM-J6 [For Individual exhaust spacer only] ●(Scale 2/3, Unit mm) 41.5 Note: When using two piping blocks. 17.5 φ12 23 (58) 157 4 φ10 250 ●Muffler : KM-J8 [For Individual exhaust spacer only] ●(Scale 2/3, Unit mm) 64 φ15 (38) 26 φ8 138 3 Note φ6 141 DIN rail length Note 275 L2 φ18 122 DIN rail length 250 L1 3・5 (R) port 4 (A) port Unit dimensions Number of units 2 1 (P) port 2 (B) port SOLENOID VALVES F SERIES (7.5) (3) Dimensions of DIN rail mounting hole 20 18.3 15.5 20.5 46 44.5 81 (77.5) 35 5.5 32 25 601 602 SOLENOID VALVES SERIES INDEX 604 Dimensions of Single Valve Unit 608 Dimensions of Monoblock Manifold 611 Dimensions of Split Manifold Non-Plug-in Type 613 Dimensions of Split Manifold Plug-in Type 614 Dimensions of Serial Transmission Compatible Manifold 617 SOLENOID VALVES F SERIES Specifications 603 F18 SERIES SPECIFICATIONS Specifications Basic Models and Functions Basic model Item F18T3 F18T4 F18T5 F18T1 F18T0 F18T2 Number of positions 2 positions 3 positions Number of ports 5 For single solenoid only Valve function For both single and double solenoid All port block, ABR connection, PAB connection Remark: For the optional specifications and order code, see p.532 ~ 556. Specifications Basic model Item F18T0 F18T1 F18T2 F18T3 F18T4 F18T5 F18T0G F18T1G F18T2G F18T3G F18T4G F18T5G F18T0V F18T1V F18T2V F18T3V Air Media Operation method External pilot type (for positive pressure) Internal pilot type Effective area〔CV〕Note1 mm2 Port size Note2 External pilot type (for vacuum) 18〔1〕 Fitting for bothφ8 andφ10, Rc1/4 M5×0.8, fitting for bothφ8 andφ10, Rc1/4 Not required Lubrication 0.15∼0.7MPa{1.5∼7.1kgf/cm2} Main valve Operating pressure range External pilot MPa {kgf/cm2} Proof pressure Response time Note4 ms ON/OFF time 0∼0.7MPa{0∼7.1kgf/cm2}Note3 0.15MPa∼−100kPa{1.5kgf/cm2∼−750.1mmHg} 0.2∼0.7MPa{2∼7.1kgf/cm2}Note3 0.2∼0.7MPa{2∼7.1kgf/cm2} 1.05{10.7} DC12V, DC24V Max. 25/35 Max. 15/70 Max. 25/35 Max. 15/70 Max. 25/35 Max. 15/70 AC100V Max.25/35 Max. 15/70 Max. 25/35 Max. 15/70 Max. 25/35 Max. 15/70 Maximum operating frequency Hz Minimum time to energize for self holding Note5 ms 5 50 50 50 5∼50 Operating temperature range (atmosphere and media) ℃ 2 m/s{G} Shock resistance 1373 {140.0} (Axial direction 294.2 {30.0}) 294.2 {30.0} 1373 {140.0} (Axial direction 294.2 {30.0}) 294.2 {30.0} 1373 {140.0} (Axial direction 294.2 {30.0}) 294.2 {30.0} Any Mounting direction Notes: 1. 2. 3. 4. For details, see the effective area on p.605. For details, see the port size on p.605. When the main valve pressure is 0.2~0.7MPa, set the external pilot pressure to the main valve pressure or higher, and to 0.7MPa or less. Values when air pressure is 0.5MPa. For switching phase timing, add a maximum of 5 ms to the response time of AC specification. The values for 2-position valves are when used as a single solenoid, and the values for 3-position valves are those switching from the neutral state of all port block. 5. When used as a double solenoid valve. Excludes T0. Remark: Conversion to psi., 1MPa=145psi., 1kgf/cm2=14.2psi., e.g. 0.15MPa=21.8psi. Solenoid Specifications Rated voltage Item Voltage range V Rated frequency Current DC24V DC12V 10.8∼13.2 21.6∼26.4 90∼110 (12±10%) (24±10%) (100±10%) Hz mA(r.m.s) Starting (When rated voltage is applied) Power consumption Allowable leakage current LED indicator color Note3 Surge suppression (as standard) 60 10Note1 10Note1 10Note1 76 38 0.9 0.9 1.0VA mA 4.0 2.0 2.0 Type B Min.100 MΩ SA:Red, SB:Green SA:Red, SB:Green Flywheel diode Notes: 1. Since the AC types have built-in bridge diodes, the starting current and energizing current value are virtually the same. 2. Value at DC500V megger. 3. The indicator color for T0 is red only. 604 50 10Note1 W Energizing Type of insulation Insulation resistance Note 2 AC100V SA:Red, SB:Green Bridge diode Cylinder Operating Speed Flow Rate How to obtain the cylinder speed Maximum operating speed Supply pressure MPa 0.7 Cylinder stops Cushion impact Time 1200 1000 800 φ50 φ63 600 10 20 30 40 50 60 70 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 250 500 750 1000 1250 1500 1750 Flow rate R/min (ANR) How to read the graph If supply pressure is 0.5MPa and flow rate is 1000R/min (ANR), the valve output pressure becomes 0.4MPa. % Delay time Delay time 0.6 200 Load ratio 0.5MPa 0.7 0.5 φ100 0 Load MPa 0.6 0 φ80 400 Measuring conditions ●Air pressure:0.5MPa{5.1kgf/cm2} ●Piping (outer diameter × inner diameter × length):φ10 ×φ7.5 × 1000mm ●Fitting:Quick fitting TS10-02 Load ●Load ratio= (%) Cylinder theoretical thrust ●Cylinder stroke:150mm Valve output pressure t3 t2 Cylinder starts Solenoid valve energized t1 Maximum operating speed Cylinder stroke mm/s 1500 1400 s 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 φ100 φ80 φ63 φ50 10 20 30 40 50 60 70 % Load ratio Note: Delay time may vary according to the cylinder stroke. Port Size Description/Piping specification PR P2 A, B P, R With sub-base M5×0.8 M5×0.8 Rc1/4 Rc1/4 With female thread block ― ― Rc1/4 Rc1/4 With different size fitting block ― ― For both φ8 andφ10 Rc1/4 With single size fitting block ― ― φ8 orφ10 Rc1/4 Monoblock type with female thread block M5×0.8 M5×0.8 Rc1/4 Rc3/8 Monoblock type with fitting block M5×0.8 M5×0.8 For both φ8 andφ10 Rc3/8 Monoblock type with single size fitting block M5×0.8 M5×0.8 φ8 orφ10 Rc3/8 Split type with female thread block, or serial transmission type with female thread block ― M5×0.8 Rc1/4 Split type with fitting block, or serial transmission type with fitting block ― M5×0.8 For both φ8 andφ10 Split type with single size fitting block, or serial transmission type with single size fitting block ― M5×0.8 φ8 orφ10 SOLENOID VALVES F SERIES Manifold Single unit ●F18 Series Rc3/8 φ12 Effective Area〔Cv〕 ●When using as a single unit Basic model F18T0□-F5 F18T1□-F5 F18T2□-F5 F18T3□-F5 F18T4□-F5 F18T5□-F5 F18T0□-F6 F18T1□-F6 F18T2□-F6 F18T3□-F6 F18T4□-F6 F18T5□-F6 mm2 ●When mounted on a manifold Manifold model Effective area〔Cv〕 Valve type 15.0〔0.83〕 16.5〔0.91〕 F18T0□ F18T1□ F18T2□ F18T3□ F18T4□ F18T5□ F18M□F mm2 F18M□A Output port Fitting for both φ8 and 17.0〔0.94〕 16.0〔0.89〕 φ10, Female thread F18M□N 18.0〔1〕 Output port φ8 fitting 15.0〔0.83〕 14.7〔0.82〕 16.7〔0.93〕 Output port φ10 fitting 16.5〔0.91〕 15.0〔0.83〕 17.0〔0.94〕 Caution: When you use the individual air supply spacer or the individual air exhaust spacer, effective area decreases about 30%. 605 Mass Single Valve Unit Mass g F18T□□-FJ F18T□□ F18T□□-A1 F18T□□-A2 Output section Output section Output section Output section Output section Output section None With plate With plate With different size fitting block Withφ8 fitting block Withφ10 fitting block Input section None Input section None Input section With A type sub-base Input section None Input section None Input section None 118 144 308 159 184 193 F18T□□-FM F18T□□-F3 F18T□□-F4 F18T□□-F5 F18T□□-F6 F18T□□-FJ6 F18T□□-FJ5 g Output section Output section Output section Output section Output section With female thread block With different size fitting block With female thread block With φ8 fitting block With φ10 fitting block Input section None Input section Input section Input section Input section With female thread block With female thread block With female thread block With female thread block 147 184 172 209 218 Basic Type F18T0 is 15g less than the mass shown above. Monoblock Manifold Mass (included single valve unit) g Mass calculation of each unit Monoblock manifold A, B port output specifications Female thread Different size fitting block φ8 fitting block φ10 fitting block A type (334×n)+165 (344×n)+165 (369×n)+165 (378×n)+165 F type (222×n)+70 (232×n)+70 (257×n)+70 (266×n)+70 Calculation example : F18M8AM stn.1∼stn.8 F18T1-A1-PS DC24V (334×8)+165=2837g When mounting a block-off plate, calculate the female thread specifications at 110g less than the above calculation results per unit, while the differing size fitting specifications are 120g, φ8 fitting specifications 145g, and the φ10 fitting specifications 154g less. When mounting the F18T0 specifications, subtract 15g per unit from the above calculation results. Mass of Split Manifold and Serial Transmission Compatible Type The split manifold has the same mass as that for the combination of valve output and manifold output specifications. The mass can only change with selection of the type of input/output block. Split Manifold Non-Plug-in Type (included single valve unit) g Mass calculation of each unit Non-plug-in type A, B port output specifications Female thread Different size fitting block φ8 fitting block φ10 fitting block (241×n)+234 (251×n)+234 (276×n)+234 (285×n)+234 g Additional mass Piping block specification Female thread Fitting block 164 189 Calculation example : F18M8N-MR stn.1∼stn.8 F18T1-A1-PS DC24V (241×8)+234+164=2326g When mounting a block-off plate, calculate the female thread specifications at 110g less than the above calculation results per unit, while the differing size fitting specifications are 120g, φ8 fitting specifications 145g, and the φ10 fitting specifications 154g less. When mounting the F18T0 specifications, subtract 15g per unit from the above calculation results. 606 Mass Mass of Split Manifold Plug-in Type/ Serial Transmission Compatible Type (included single valve unit) g Mass calculation of each unit Plug-in type Serial transmission compatible type A, B port output specifications Female thread Different size fitting block φ6 fitting block φ8 fitting block (243×n)+238 (253×n)+238 (278×n)+238 (287×n)+238 g Additional mass Piping block specification Female thread Fitting block 174 199 g Additional mass Wiring block specification -F100, -F101 -F200, -F201, -F260 -D250, -D251 -T200 69 71 72 154 g Transmission block mass Serial transmission blockNote YS□□ YS391 160 110 Calculation example : F18M8PM-MR-F201 DC24V stn.1∼stn.8 F18T1-A1 DC24V (243×8)+238+174+71=2427g When mounting a block-off plate, calculate the female thread specifications at 110g less than the above calculation results per unit, while differing size fitting specifications are 120g, φ8 fitting specifications 145g, and the φ10 fitting specifications 154g less. When mounting the F18T0 specifications, subtract 15g per unit from the above calculation results. SOLENOID VALVES F SERIES Note : For the serial transmission compatible manifold, add to the calculation the wiring block YS391-F201(71g). 607 F18 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F18T F18T Valve specification -F3-PS With output port different size fitting block With input port female thread block S type plug connector ※For T0 type dimensions, see p.609. (74.5) 63 20 2.5 10 27 7 A B Manual override 2-φ4.5 (Mounting hole) ( 4 A)port 19 40 54 22.5 (R2) 3 17.5 19 19 49.5 (P) 1 88.5 19 (R1) 5 96.2 Quick fitting (φ8,φ10) 143.5 3-Rc1/4 2 ( 2 B)port 2 2 34 Mounting bracket(F18Z-21)Note φ17 11 Note: The mounting bracket is additional part (sold separately). 4 19 1.6 2-φ4.5 (Mounting hole) 6 11 F18T Valve specification -F4-PS With output port female thread block With input port female thread block S type plug connector ※For T0 type dimensions, see p.609. (55.5) 20 44 2.5 10 27 7 A B Manual override 2-φ4.5 (Mounting hole) 2 19 40 54 17.5 19 88.5 19 22.5 2 (B)port 2 (R2) 3 49.5 (P) 1 96.2 2-Rc1/4 19 (R1) 5 2 4 (A)port 143.5 3-Rc1/4 34 Mounting bracket(F18Z-21)Note 11 Note: The mounting bracket is additional part (sold separately). 4 19 1.6 2-φ4.5 (Mounting hole) 6 11 608 F18 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) -F5: (71.5) -F6: (77.5) F18T0-F□-PS -F5:70 -F6:76 (300) With output port single size fitting block 20 With input port female thread block 10 S type plug connector 2.5 18 27 7 Manual override 4 (A)port (PR) 2 (B)port 5 (R1)port PUSH 1 (P)port LOCK 19 28 34 2-φ4.5 (Mounting hole) Single size fitting -F5:φ8 -F6:φ10 4 11 1.6 6 11 2-φ4.5 (Mounting hole) Note: The mounting bracket is additional part (sold separately). SOLENOID VALVES F SERIES 2 19 2 84.2 19 54 10.5 14 3-Rc1/4 17.5 76.5 37.5 19 19 131.5 3 (R2)port 609 F18 Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) F18T F18T Valve specification Operation method -A2-PS With A type sub-base S type plug connector 2.5 10 27 A B Manual override M5×0.8 3-Rc1/4 31 ●For double solenoid ●or 3-position valve 20 20 (P) 1 PR 143.5 96.2 88.5 72 10 24 18 34 30 15 3.5 37 20 25 34 (67.5) B side manual override 15 13.5 6 3 (R2) 2 (B) 23.5 60 4 (A) 20 16.5 P2 (R1) 5 2-φ4.5 (Mounting hole) 2-Rc1/4 36 (P2 port)M5×0.8 (For external pilot specification) Note : The T0 type is 12mm shorter for the total valve length (the end cover protrusion is 12mm shorter). Option Made to Order ●L type plug connector : -PL ●Manual lever override (Scale 2/3, Unit mm) 43.5 A B 3 2 (B) Note : The T0 type is 12mm shorter for the total valve length (the end cover protrusion is 12mm shorter). 610 36.3 (R1) 5 (P) 1 3 (R2) 4 (A) 132.5 P2 PR A B F18 Series Dimensions of Monoblock Manifold A Type (Scale 1/3, Unit mm) F18M J AM Number of units F18MA Pilot specification (base piping type) Monoblock manifold A type With manifold output port different size fitting block S type plug connector L 19 19 19 19 (pitch) Manual override ●Internal pilot specification A B A B A B 2-M5×0.8(Both sides) 6-Rc3/8(Both sides) 162 23 96.2 25 5 ●External pilot specification(Note) 25 14 5 Block-off plate Quick fitting (φ8, φ10) 〔Can also select Rc1/4 female thread〕 5 20 19 90.5 17 53 P 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 4 (A)port Note: For the external pilot specifications, the basic shape of the monoblock manifold A body type differs from the internal pilot specifications. F18M Number of units AL Pilot specification (base piping type) L Monoblock manifold A type With manifold output port single size fitting block S type plug connector 19 (pitch) 19 Manual override 19 2-M5 (PR) (Both sides) Unit dimensions 5 (R1)port 1 (P)port PUSH 3 (R2)port PUSH A PUSH A LOCK 77 23 25 12 2 (B)port B -J5:28 -J6:34 PUSH P (5) stn.1 stn.2 stn.3 stn.4 stn.5 18 L P 2 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 Number of units 19 Single size fitting -J5:φ8 -J6:φ10 17 37 4 (A)port (90.5) 40 PUSH 5 25 LOCK B 12.5 15 LOCK 53 6-Rc3/8 (Both sides) 4-φ4.5 (Mounting hole) PUSH A LOCK 84.2 96.2 24.5 71 LOCK 131.5 143.5 24.5 -J5:159 -J6:165 LOCK 611 SOLENOID VALVES F SERIES 65 12 3 (R2) 24.5 24.5 5 (R1) (P) 1 P2 PR L 2 Number of units stn.1 stn.2 stn.3 stn.4 18 2 (B)port 6-Rc3/8(Both sides) 2-M5×0.8(Both sides) P 37 2-M5×0.8(Both sides) Unit dimensions 31 15 12.5 12 3 (R2) 24.5 71 (P) 1 24.5 143.5 PR 5 (R1) 25 40 77 (For external pilot specification : 76) 4-φ4.5 F18 Series Dimensions of Monoblock Manifold F Type (Scale 1/3, Unit mm) F18M F18MF F (direct piping type) Number of units Monoblock manifold F type With valve output port different size fitting block S type plug connector L 19 19 19 19 (pitch) Manual override A B A B A B 2-M5×0.8 (Both sides) Unit dimensions ( 4 A)port 14.5 15 13 75 23 23.5 19 40 96.2 ( 3 R2) (P) 1 23 23 ( 5 R1) 34 PR 35 4-φ4.5 (B) 2 port 143.5 6-Rc3/8 (Both sides) 22 5 P 5 stn.1 stn.2 stn.3 stn.4 Quick fitting(φ8, φ10) 18 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 (97.5) 63 28 34 Block-off plate Note : The T0 type is 12mm shorter for the total valve length (the end cover protrusion is 12mm shorter). 612 L P 2 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 Number of units F18 Series Dimensions of Split Manifold Non-Plug-in Type (Scale 1/3, Unit mm) Number of units F18MNJ J Pilot specification (base piping type) M N L With manifold output port different size fitting block S type plug connector 19 20 19 (pitch) 26.5 M5×0.8(P2 port) (For external pilot specification) 2 Manual override A B A B A B 4-φ4.4(Oval hole) (Mounting hole) Unit dimensions L P 2 91 78 3 110 97 4 129 116 5 148 135 6 167 154 7 186 173 8 205 192 9 224 211 10 243 230 11 262 249 12 281 268 13 300 287 14 319 306 15 348 325 16 357 344 17 376 363 18 395 382 19 414 401 20 433 420 P 6.5 90 17.4 6.5 Block-off plate stn.1 stn.2 stn.3 stn.4 Quick fitting (φ8, φ10) 〔Can also select Rc1/4 female thread〕 26 5.5 5.5 15 96.2 79 143.5 15 Number of units Quick fitting (φ12) 〔Can also select Rc3/8 female thread〕 21 24 3・5 (R)port 2 (B)port 4 (A)port F18MN 32.8 Number of units N Pilot specification (direct piping type) L With valve output port different size fitting block S type plug connector 19 20 19 (pitch) 26.5 2 Manual override A B A B 4-φ4.4(Oval hole) (Mounting hole) A B L P 91 78 3 110 97 4 129 116 ( 1 P)port 5 148 135 3・5(R)port 6 167 154 7 186 173 8 205 192 9 224 211 10 243 230 11 262 249 12 281 268 13 300 287 14 319 306 15 348 325 16 357 344 17 376 363 18 395 382 19 414 401 20 433 420 79 5.5 5.5 15 19.2 40 24 19 96.2 143.5 ( 2 B)port 6.5 P stn.1 stn.2 stn.3 stn.4 18 Unit dimensions 2 Quick fitting (φ12) 〔Can also select Rc3/8 female thread〕 15 Quick fitting (φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 ( 4 A)port M5×0.8(P2 port) (For external pilot specification) 90 54 19 ( 1 P)port Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. 18 6.5 21 54 76 (117) 63 Block-off plate 93.4 F18M 76 (91) 37 18 Note : The T0 type is 12mm shorter for the total valve length (the end cover protrusion is 12mm shorter). Number of units Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. 613 SOLENOID VALVES F SERIES F18M F18 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) Combination of F18MPJ and F18-CONT With manifold output port different size fitting block Flat cable connector 10-pin specification 20 19 (pitch) 19 16 21 A B 2 A B M5×0.8(P2 port) (For external pilot specification) A B P 1 P)port ( 3・5 (R)port 21 76 24 18 32.8 19 54 40 (91) (72.5) 37 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 (P) 1 port 3・( 5 R)port ( 2 B)port ( 4 A)port J Pilot specification (base piping type) M 19 16 21 A B 20 19 (pitch) 112 99 3 131 118 4 150 137 5 169 156 6 188 175 7 207 194 8 226 213 M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 2 A B 18 90 6.5 Block-off plate 21 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 76 24 2 (B)port 4 (A)port 32.8 19 18 40 54 (72.5) 37 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 P stn.1 stn.2 stn.3 stn.4 26 5.5 5.5 15 96.2 79 127 132.5 Applicable connector:20-pin 〔MIL-C-83503 conformity〕 6.5 (91) L 2 15 A B 614 P Number of units L With manifold output port different size fitting block Flat cable connector 20-pin specification Manual override Unit dimensions Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. 17.4 P 32.8 6.5 stn.1 stn.2 stn.3 stn.4 18 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 Number of units 2-Rc3/8 18 19 15 5.5 Applicable connector:10-pin 〔MIL-C-83503 conformity〕 6.5 F18M 16 7 2-Rc1/4 24 90 17.4 96.2 127 132.5 15 A B M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 15 Manual override Female thread specification (Scale1/4, Unit mm) L 26 P 79 Number of units 5.5 F18M J M Pilot specification (base piping type) ( 1 P)port 3・5 (R)port Unit dimensions P Number of units L 2 112 99 3 131 118 4 150 137 5 169 156 6 188 175 7 207 194 8 226 213 9 245 232 10 264 251 11 283 270 12 302 289 13 321 308 14 340 327 15 359 346 16 378 365 Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. F18 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) Combination of F18MPJ and F18-CONT Number of units P With manifold output port different size fitting block Flat cable connector 26-pin specification L 20 19 (pitch) 19 Manual override 16 21 A B A B M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 2 A B Unit dimensions Applicable connector:26-pin 〔MIL-C-83503 conformity〕 P stn.1 stn.2 stn.3 stn.4 18 6.5 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 90 17.4 26 5.5 5.5 15 96.2 79 127 132.5 15 Number of units 6.5 21 P P 112 99 3 131 118 4 150 137 5 169 156 6 188 175 7 207 194 8 226 213 9 245 232 10 264 251 11 283 270 12 302 289 13 321 308 14 340 327 15 359 346 16 378 365 17 397 384 18 416 403 19 435 422 20 454 441 Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. J Pilot specification (base piping type) M With manifold output port different size fitting block D sub connector 25-pin specification L 19 Manual override 16 21 A B A B 20 19 (pitch) M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 2 A B Unit dimensions stn.1 stn.2 stn.3 stn.4 18 90 6.5 21 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 18 40 61 54 ( 2 B)port ( 4 A)port 76 24 (91) 37 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 P 26 D sub connector 〔MIL-C-24308 conformity〕 2-M2.6 6.5 17.4 5.5 5.5 15 96.2 79 127 132.5 15 Number of units 32.8 Number of units ( 1 P)port 3・5 (R)port 19 F18M 76 24 19 18 40 2 (B)port 4 (A)port 32.8 54 (91) (72.5) 37 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 L 2 (P) 1 port 3・( 5 R)port L P 2 112 99 3 131 118 4 150 137 5 169 156 6 188 175 7 207 194 8 226 213 9 245 232 10 264 251 11 283 270 12 302 289 13 321 308 14 340 327 15 359 346 16 378 365 17 397 384 18 416 403 19 435 422 20 454 441 Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. 615 SOLENOID VALVES F SERIES F18M J Pilot specification (base piping type) M F18 Series Dimensions of Split Manifold Plug-in Type (Scale 1/3, Unit mm) F18M Number of units P Combination of F18MPJ and F18-CONT J Pilot specification (base piping type) M L With manifold output port different size fitting block Terminal block type 19 16 42 19 20 (pitch) M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 2 Manual override A B A B A B 127 90 17.4 6.5 P stn.1 stn.2 stn.3 stn.4 18 Quick fitting(φ8, φ10) 〔Can also select Rc1/4 female thread〕 26 79 5.5 5.5 M3 screw 6.5 21 F18M Number of units PL 76 24 32.8 18 40 19 54 78 (91) 37 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 2 (B)port 4 (A)port L P 2 133 120 3 152 139 4 171 158 5 190 177 6 209 196 7 228 215 8 247 234 9 266 253 10 285 272 11 304 291 12 323 310 13 342 329 14 361 348 15 380 367 16 399 386 17 418 405 18 437 424 Number of units 15 96.2 132.5 1 3 5 7 9 11 13 15 17 COM 2 4 6 8 10 12 14 16 18 15 Unit dimensions Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. ( 1 P)port 3・5 (R)port Pilot specification (base piping type) L With manifold output port single size fitting block Flat cable connector 20-pin specification Manual override Applicable connector:20-pin 〔MIL-C-83503 conformity〕 16 19(pitch) 21 26.5 20 19 Unit dimensions PUSH A PUSH A LOCK PUSH A PUSH Number of units A LOCK LOCK LOCK B 4(A)port -J5:23 -J6:29 (6.5) P Single size fitting -J5:φ8 -J6:φ10 stn.1 stn.2 stn.3 stn.4 stn.5 2(B)port 18 17.4 5.5 5.5 15 PUSH 2 4-φ4.4(Oval hole) 6.5 (Mounting hole) 21 Fitting(φ12) 1(P)port 76 24 32.8 19 18 40 54 (72.5) 91 37 3・5(R)port 616 L P 2 112 99 3 131 118 4 150 137 5 169 156 6 188 175 7 207 194 8 226 213 9 245 232 10 264 251 11 283 270 12 302 289 13 321 308 14 340 327 15 359 346 16 378 365 17 397 384 18 416 403 19 435 422 20 454 441 LOCK B PUSH 90 79 84.2 127 120.5 96.2 132.5 LOCK Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. F18 Series Dimensions of Serial Transmission Compatible Manifold (Scale 1/3, Unit mm) ※For dimensions of manifold for Omron CompoBus / D, see p. 618. F18M Number of units S F18MSJ J Pilot specification (base piping type) M L With manifold output port different size fitting block 27 Manual override 19 16 A B M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 2 A B 15 A B 20 19 (pitch) 5 90 127 P stn.1 stn.2 stn.3 stn.4 6.5 17.4 6.5 Quick fitting (φ8, φ10) 〔Can also select Rc1/4 female thread〕 Block-off plate 21 18 50 26 90 5.5 5.5 YS201S MADE IN JAPAN G 24V 0V 15 79 132.5 96.2 D ADDRESS 1 2 4 8 16 32 64128 G 24V 0V POWER SEND D 142160 Serial transmission block Note: Panel design differs depending on the transmission block specifications F18MS S (direct piping type) L With valve output port different size fitting block 27 Manual override 19 16 A B A B 20 19 (pitch) M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 2 A B ( 4 A)port ( 2 B)port 15 (P) 1 port Quick fitting (φ8, φ10) 〔Can also select Rc1/4 female thread〕 〔Can also select single size fitting〕 40 127 90 79 19 P 78 141 3 160 97 4 179 116 198 135 217 154 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 7 236 173 8 255 192 9 274 211 10 293 230 11 312 249 12 331 268 13 350 287 14 369 306 15 388 325 16 407 344 21 Block-off plate 93.4 50 76 71.8 L 2 6 (117) 63 5 Number of units 5 stn.1 stn.2 stn.3 stn.4 18 Unit dimensions 6.5 5.5 5.5 P 6.5 Serial transmission block Note: Panel design differs depending on the transmission block specifications 54 40 90 96.2 15 YS201S 142160 MADE IN JAPAN G 24V 0V 24 132.5 D ADDRESS 1 2 4 8 16 32 64128 G 24V 0V POWER SEND D 3・( 5 R)port Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. 617 SOLENOID VALVES F SERIES Number of units (P) 1 port 3・( 5 R)port 19.2 F18M 76 24 18 ( 2 B)port ( 4 A)port 32.8 19 71.8 40 54 (91) 37 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 F18 Series Dimensions of OMRON Corporation CompoBus/D Serial Transmission Compatible Manifold (Scale 1/3, Unit mm) F18M Number of units S J Pilot specification (base piping type) M With manifold output port different size fitting block L Manual override 19 90 16 21 A B A B 20 19 (pitch) M5×0.8(P2 port) (For external pilot specification) 4-φ4.4(Oval hole) (Mounting hole) 26.5 2 A B 15 132.5 DRT1-OD16X 127 REMOTE ADAPTER 24VDC 21 Quick fitting(φ12) 〔Can also select Rc3/8 female thread〕 316 213 9 335 232 10 354 251 11 373 270 12 392 289 13 411 308 14 430 327 15 449 346 16 468 365 Additional Parts (Sold Separately) ●Muffler : KM-J12 [For both plug-in and non-plug-in type] ●(Scale 2/3, Unit mm) 83 A B A B A B 35 φ12 φ20 Remark: When using two piping blocks, add 21 to the L and P dimensions shown above. ( 1 P)port 3・5 (R)port 2 (B)port 4 (A)port 143.7 194 8 24 297 76 175 7 32.8 278 19 156 6 18 137 259 40 240 5 37 4 54 118 53 99 221 0.5 202 3 (91) 2 17.4 6.5 Block-off plate P (72.5) L P stn.1 stn.2 stn.3 stn.4 18 6.5 Unit dimensions 26 5.5 5.5 15 OUT Serial transmission block Omron remote adaptor Model DRT1-OD16X Number of units 90 80.5 79 MS NS 96.2 62 50 85 ●Muffler:KM-J8 [For Individual exhaust spacer only] ●(Scale 2/3, Unit mm) 64 (38) (64) φ8 φ15 26 ●Muffler:KM-J10 [For Individual exhaust spacer only] ●(Scale 2/3, Unit mm) 73 618 φ10 φ18 30 F SERIES SPECIFICATIONS CONFIRMATION FORM INDEX 622 Monoblock Manifold F Type 623 PC Board Manifold A Type 624 PC Board Manifold F Type 625 Split Manifold Non-Plug-in Type 626 Split Manifold Plug-in Type 628 Serial Transmission Compatible Manifold 630 SOLENOID VALVES F SERIES Monoblock Manifold A Type 619 Example of Specifications Confirmation Form Example 1 When ordering F series manifolds, use this specifications confirmation form for complex model configurations, for confirming specifications, etc. Using the example below for reference, fill out the required items in the "Specifications Confirmation Forms" found on p. 622 and up, and send it. (Make copies of the Specifications Confirmation Form for your use.) Order Date Month/ Day/ Year/ Company name Name of the person in charge Monoblock Manifold A type Order No. Specifications Confirmation Form Equipment name Manifold model ●Fill in selections inside the thick-lined boxes. F 10 M 8 A Valve size Valve units 10 : 10mm width 2∼20 15 : 15mm width 18 : 18mm width stn. F Station 1 J Illustration shows the F10 series. A B A B A B Manifold output specification J : With different size fitting block M : With female thread block L : With single size fitting block Valve size Solenoid Pilot specification Blank : Internal pilot manifold G : External pilot manifold Left side T Valve specification - Note 3 - A1- PS - Note 4 - Note 5 Right side DC24V Operation method Manual override Blank : Internal pilot type Note 1 Blank : Manual override Note 2 G : External pilot type (for positive pressure) R : Manual leve r V : External pilot type (for vacuum) Note 2 overrideNote 3 (made to order) Mounting valve models 2 …… n Voltage DC24V DC12V AC100V Individual air supply and exhaust spacer Note 5 Blank : Without spacer CPS : Plus common pre-wiring connection NPM : Individual air supply spacer (with M5 female thread for F10) S type plug connector NP6 : Individual air supply spacer (with φ6 fitting for F15) Lead wire 300mm NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) CPL : Plus common pre-wiring connection NP0 : Individual air supply spacer (with φ10 fitting for F18) L type plug connector NRM : Individual exhaust spacer (with M5 female thread for F10) Lead wire 300mm NR6 : Individual exhaust spacer (with φ6 fitting for F15) CPS3 : Plus common pre-wiring connection NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) S type plug connector NR0 : Individual exhaust spacer (with φ10 fitting for F18) Lead wire 3000 mm CPL3 : Plus common pre-wiring connection Manifold fitting specificationNote 4 L type plug connector J5 : Can be selected with manifold output specification L (with single size fitting block). Lead wire 3000 mm Manifold side output port single size fitting F10:φ4, F15:φ6, F18:φ8 J6 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ6, F15:φ8, F18:φ10 Wiring specification Blank : L type plug connector Without connector PN : S type plug connector Without connector PS : S type plug connector Lead wire length 300mm PL : L type plug connector Lead wire length 300mm PS3 : S type plug connector Lead wire length 3000 mm PL3 : L type plug connector Lead wire length 3000 mm ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station F□T0 2-position, single solenoid only F□T1 2-position, single solenoid specification F□T2 2-position, double solenoid specification F□T3 3-position, all port block 1 2 ○ ○ 3 4 F□T5 F□BP 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity 2 2 2 1 1 ○ ○ ○ ○ ○ F□T4Note 6 3-position, ABR connection Note 6 5 ○ 3-position, PAB connection Block-off plate Manual override (-R) Manual lever override ○ Manifold fitting J5 Manifold output port single size fitting block specificationNote 4 J6 Manifold output port single size fitting block NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 Individual air supply spacer (with φ10 fitting for F18) ○ 2 ○ ○ 2 NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 Individual exhaust spacer (with φ10 fitting for F18) Notes: 1. Cannot be mounted on the external pilot manifold. 2. Cannot be mounted on the internal pilot manifold. 3. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 4. When the manifold output specifications are L(with single size fitting block), select from J5 or J6 in the manifold fitting specifications column of the above table, and enter ○ for each station. 5. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. 6. Not available with vacuum valve. Quantity Delivery set 5 622 620 June 1 Example of Specifications Confirmation Form Example 2 Order Date Month/ Day/ Year/ Company name Name of the person in charge Monoblock Manifold F Type Order No. Specifications Confirmation Form Equipment name ●Fill in selections inside the thick-lined boxes. Manifold model Station 1 F 10 M 8 2 …… n F A B A B A B Valve units Valve size 10 : 10mm width 2∼20 15 : 15mm width 18 : 18mm width stn. F Solenoid Left side Valve size T Valve specification - Note 1 - Note 2 - PS - Note 3 Right side AC100V Illustration shows the F10 series. Valve output type FJ : With different size fitting block (F10:φ4 and φ6, F15:φ6 andφ8, F18:φ8 and φ10)Note 2 FJ5 : With single size fitting block (F10:φ4, F15:φ6, F18:φ8)Note 2 FJ6 : With single size fitting block (F10:φ6, F15:φ8, F18:φ10)Note 2 FM : With female thread block (F10:M5×0.8, F15:Rc1/8, F18:Rc1/4)Note 2 Wiring specification Blank : L type plug connector Without connector PN : S type plug connector Without connector PS : S type plug connector Lead wire length 300mm PL : L type plug connector Lead wire length 300mm PS3 : S type plug connector Lead wire length 3000 mm PL3 : L type plug connector Lead wire length 3000 mm Individual air supply and exhaust spacer Note 3 Blank : Without spacer NPM : Individual air supply spacer (with M5 female thread for F10) NP6 : Individual air supply spacer (with φ6 fitting for F15) NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 : Individual air supply spacer (with φ10 fitting for F18) NRM : Individual exhaust spacer (with M5 female thread for F10) NR6 : Individual exhaust spacer (with φ6 fitting for F15) NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 : Individual exhaust spacer (with φ10 fitting for F18) CPS : Plus common pre-wiring connection S type plug connector Lead wire 300mm CPL : Plus common pre-wiring connection L type plug connector Lead wire 300mm CPS3 : Plus common pre-wiring connection S type plug connector Lead wire 3000 mm CPL3 : Plus common pre-wiring connection L type plug connector Lead wire 3000 mm ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station F□T0 2-position, single solenoid only F□T1 2-position, single solenoid specification F□T2 2-position, double solenoid specification F□T3 3-position, all port block F□T4 3-position, ABR connection F□T5 3-position, PAB connection F□BP Block-off plate 1 2 ○ ○ 3 4 ○ ○ 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity ○ 2 2 2 1 1 ○ 4 1 1 2 ○ ○ ○ SOLENOID VALVES F SERIES Voltage DC24V DC12V AC100V SOLENOID VALVES F SERIES Mounting valve models Manual override Blank : Manual override R : Manual leve r overrideNote 1 (made to order) Manual override (-R) Manual lever override FJ With different size fitting block Valve output type Note 2 FJ5 With single size fitting block FJ6 With single size fitting block FM With female thread block NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 Individual air supply spacer (with φ10 fitting for F18) ○ ○ ○ ○ ○ ○ ○ NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 Individual exhaust spacer (with φ10 fitting for F18) Notes: 1. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 2. Select from FJ, FJ5, FJ6, FM in the valve type column of the above table, and enter ○ for each station. 3. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. Quantity 5 Delivery set June 1 623 621 Order Date Month/ Day/ Year/ Company name Name of the person in charge Monoblock Manifold A type Order No. Specifications Confirmation Form Equipment name Manifold model ●Fill in selections inside the thick-lined boxes. F M A Valve size Valve units 10 : 10mm width 2∼20 15 : 15mm width 18 : 18mm width stn. Station 1 F Illustration shows the F10 series. A B A B A B Manifold output specification J : With different size fitting block M : With female thread block L : With single size fitting block Valve size Solenoid Pilot specification Blank : Internal pilot manifold G : External pilot manifold Left side T Valve specification - Note 3 - A1- Right side - Note 4 - Note 5 Voltage DC24V DC12V AC100V Manual override Operation method Blank : Manual override Blank : Internal pilot type Note 1 G : External pilot type (for positive pressure) Note 2 R : Manual lever V : External pilot type (for vacuum) Note 2 overrideNote 3 (made to order) Mounting valve models 2 …… n Individual air supply and exhaust spacer Note 5 Blank : Without spacer NPM : Individual air supply spacer (with M5 female thread for F10) NP6 : Individual air supply spacer (with φ6 fitting for F15) NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 : Individual air supply spacer (with φ10 fitting for F18) NRM : Individual exhaust spacer (with M5 female thread for F10) NR6 : Individual exhaust spacer (with φ6 fitting for F15) NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 : Individual exhaust spacer (with φ10 fitting for F18) Wiring specification Blank : L type plug connector Without connector PN : S type plug connector Without connector PS : S type plug connector Lead wire length 300mm PL : L type plug connector Lead wire length 300mm PS3 : S type plug connector Lead wire length 3000 mm PL3 : L type plug connector Lead wire length 3000 mm CPS : Plus common pre-wiring connection S type plug connector Lead wire 300mm CPL : Plus common pre-wiring connection L type plug connector Lead wire 300mm CPS3 : Plus common pre-wiring connection S type plug connector Lead wire 3000 mm CPL3 : Plus common pre-wiring connection Manifold fitting specificationNote 4 L type plug connector J5 : Can be selected with manifold output specification L (with single size fitting block). Lead wire 3000 mm Manifold side output port single size fitting F10:φ4, F15:φ6, F18:φ8 J6 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ6, F15:φ8, F18:φ10 ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station F□T0 2-position, single solenoid only F□T1 2-position, single solenoid specification F□T2 2-position, double solenoid specification F□T3 3-position, all port block 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity F□T4Note 6 3-position, ABR connection F□T5Note 6 3-position, PAB connection F□BP Block-off plate Manual override (-R) Manual lever override Manifold fitting J5 Manifold output port single size fitting block specificationNote 4 J6 Manifold output port single size fitting block NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 Individual air supply spacer (with φ10 fitting for F18) NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 Individual exhaust spacer (with φ10 fitting for F18) Notes: 1. Cannot be mounted on the external pilot manifold. 2. Cannot be mounted on the internal pilot manifold. 3. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 4. When the manifold output specifications are L(with single size fitting block), select from J5 or J6 in the manifold fitting specifications column of the above table, and enter ○ for each station. 5. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. 6. Not available with vacuum valve. Quantity Delivery set 622 Order Date Month/ Day/ Year/ Company name Name of the person in charge Monoblock Manifold F Type Order No. Specifications Confirmation Form Equipment name ●Fill in selections inside the thick-lined boxes. Manifold model Station 1 F M 2 …… n F A B A B A B Valve size Valve units 10 : 10mm width 2∼20 15 : 15mm width 18 : 18mm width stn. F Solenoid Left side Valve size T Valve specification - Note 1 - Note 2 - Right side - Note 3 Illustration shows the F10 series. Voltage DC24V DC12V AC100V Valve output type FJ : With different size fitting block (F10:φ4 and φ6, F15:φ6 andφ8, F18:φ8 and φ10)Note 2 FJ5 : With single size fitting block (F10:φ4, F15:φ6, F18:φ8)Note 2 FJ6 : With single size fitting block (F10:φ6, F15:φ8, F18:φ10)Note 2 FM : With female thread block (F10:M5×0.8, F15:Rc1/8, F18:Rc1/4)Note 2 Wiring specification Blank : L type plug connector Without connector PN : S type plug connector Without connector PS : S type plug connector Lead wire length 300mm PL : L type plug connector Lead wire length 300mm PS3 : S type plug connector Lead wire length 3000 mm PL3 : L type plug connector Lead wire length 3000 mm Individual air supply and exhaust spacer Note 3 Blank : Without spacer NPM : Individual air supply spacer (with M5 female thread for F10) NP6 : Individual air supply spacer (with φ6 fitting for F15) NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 : Individual air supply spacer (with φ10 fitting for F18) NRM : Individual exhaust spacer (with M5 female thread for F10) NR6 : Individual exhaust spacer (with φ6 fitting for F15) NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 : Individual exhaust spacer (with φ10 fitting for F18) CPS : Plus common pre-wiring connection S type plug connector Lead wire 300mm CPL : Plus common pre-wiring connection L type plug connector Lead wire 300mm CPS3 : Plus common pre-wiring connection S type plug connector Lead wire 3000 mm CPL3 : Plus common pre-wiring connection L type plug connector Lead wire 3000 mm ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station F□T0 2-position, single solenoid only F□T1 2-position, single solenoid specification F□T2 2-position, double solenoid specification F□T3 3-position, all port block F□T4 3-position, ABR connection F□T5 3-position, PAB connection F□BP Block-off plate 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity Manual override (-R) Manual lever override FJ With different size fitting block Valve output type Note 2 FJ5 With single size fitting block FJ6 With single size fitting block FM With female thread block NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 Individual air supply spacer (with φ10 fitting for F18) NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 Individual exhaust spacer (with φ10 fitting for F18) Notes: 1. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 2. Select from FJ, FJ5, FJ6, FM in the valve type column of the above table, and enter ○ for each station. 3. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. Quantity Delivery set 623 SOLENOID VALVES F SERIES Mounting valve models Manual override Blank : Manual override R : Manual lever overrideNote 1 (made to order) Order Date PC Board Manifold A Type Specifications Confirmation Form Company name Name of the person in charge ●Fill in selections inside the thick-lined boxes. Order No. Manifold model F M AP - - Month/ Day/ Year/ Equipment name Station Valve size 10 : 10mm width 15 : 15mm width Manifold output specification Wiring specification Wiring connection specification J : With different size fitting block F200 S : Single wiring M : With female thread block F201 W : Double wiring L : With single fitting block Pilot specification Valve units Blank : Internal pilot manifold 6∼16 (only even-numbered units) G : External pilot manifold F Valve size T Valve specification Operation method Blank : Internal pilot type Note 1 G : External pilot type (for positive pressure) Note 2 V : External pilot type (for vacuum) Note 2 Wiring connection specifications are -S (for single wiring) - Note 3 ・・・・・・・・・ n A B A B A B A B A B Solenoid - A1 - PP - Manual override Blank : Manual override R : Manual lever overrideNote 3 (made to order) 2 Illustration shows the F10 series. Left side Caution: 6 or 8 units, when the wiring connection specifications are -W(double wiring). stn. 1 Note 4 - Right side Note 5 Individual air supply and exhaust spacer Note 5 Blank : Without spacer NPM : Individual air supply spacer (with M5 female thread for F10) NP6 : Individual air supply spacer (with φ6 fitting for F15) NP8 : Individual air supply spacer (with φ8 fitting for F15) NRM : Individual exhaust spacer (with M5 female thread for F10) NR6 : Individual exhaust spacer (with φ6 fitting for F15) NR8 : Individual exhaust spacer (with φ8 fitting for F15) Voltage DC24V DC12V Manifold fitting specificationNote 4 J5 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ4, F15:φ6 J6 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ6, F15:φ8 Mounting valve models ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Quantity 2-position, single solenoid only F□T0 F□T1 2-position, single solenoid specification F□BPC Block-off plate Manual override (-R) Manual lever override Manifold fitting J5 Manifold output port single size fitting block specificationNote 4 J6 Manifold output port single size fitting block NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15) NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F 15) Notes: 1. Cannot be mounted on the external pilot manifold. Caution: Valve units can be 2. Cannot be mounted on the internal pilot manifold. selected only the 3. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. even-numbered 4. When the manifold output specifications are L(with single fitting block), select from J5 or J6 in the manifold fitting specifications units between 6 column of the above table, and enter ○ for each station. and 16. 5. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. Wiring connection specifications are -W (for double wiring) ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station 1 2 3 4 5 6 7 8 Quantity 2-position, single solenoid only F□T0 F□T1 2-position, single solenoid specification Caution: Valve units are either 6 or 8 units. F□T2 2-position, double solenoid specification F□T3 3-position, all port block F□T4Note 6 3-position, ABR connection F□T5Note 6 3-position, PAB connection F□BPC Block-off plate Manual override (-R) Manual lever override Manifold fitting J5 Manifold output port single size fitting block specificationNote 4 J6 Manifold output port single size fitting block Individual air supply spacer (with M5 female thread for F10) NPM NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15) NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F 15) Notes :1. Cannot be mounted on the external pilot manifold. 2. Cannot be mounted on the internal pilot manifold. 3. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 4. When the manifold output specifications are L(with single size fitting block), select from J5 or J6 in the manifold fitting specifications column of the above table, and enter ○ for each station. 5. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. Quantity Delivery 6. Not available with vacuum valve. set 624 Order Date PC Board Manifold F Type ●Fill in selections inside the thick-lined boxes. Order No. Manifold model Specifications Confirmation Form Company name Name of the person in charge F M FP - Month/ Day/ Year/ Equipment name - Station 1 2 ・・・・・・・・・ n Illustration shows the F10 series. Valve size Wiring specification Wiring connection specification F200 S : Single wiring 10 : 10mm width Valve units 15 : 15mm width W : Double wiring F201 6∼16 (only even-numbered units) A B A B A B A B A B Solenoid Caution: 6 or 8 units, when the wiring connection specifications are -W(double wiring) Left side stn. F Valve size Manual override Blank : Manual override R : Manual lever overrideNote 1 (made to order) T - Note 1 - Note 2 -PP- Valve specification Right side Note 3 Valve type FJ : With different size fitting block (F10:φ4 and φ6, F15:φ6 and φ8)Note 2 FJ5 : With single size fitting block (F10:φ4, F15:φ6)Note 2 FJ6 : With single size fitting block (F10:φ6, F15:φ8)Note 2 FM : With female thread block (F10:M5×0.8, F15:Rc1/8)Note 2 Individual air supply and exhaust spacer Note 3 Voltage Blank : Without spacer DC24V NPM : Individual air supply spacer (with M5 female thread for F10) DC12V NP6 : Individual air supply spacer (with φ6 fitting for F15) NP8 : Individual air supply spacer (with φ8 fitting for F15) NRM : Individual exhaust spacer (with M5 female thread for F10) NR6 : Individual exhaust spacer (with φ6 fitting for F15) NR8 : Individual exhaust spacer (with φ8 fitting for F15) Wiring connection specifications are -S (for single wiring) Mounting valve, block-off plate Station F□T0 2-position, single solenoid only F□T1 2-position, single solenoid specification F□BPC Block-off plate Manual override (-R) Manual lever override FJ With different size fitting block Valve FJ5 With single size fitting block output FJ6 With single size fitting block typeNote 2 FM With female thread block 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Quantity NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15) NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F 15) Notes: 1. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. Caution: Valve units can be selected only the 2. Select from FJ, FJ5, FJ6, FM in the valve type column of the above table, and enter ○ for each station. even-numbered 3. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. units between 6 and 16. Wiring connection specifications are -W (for double wiring) ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station 1 2 3 4 5 6 7 8 Quantity F□T0 2-position, single solenoid only F□T1 2-position, single solenoid specification Caution: Valve units are either 6 or 8 units. F□T2 2-position, double solenoid specification F□T3 3-position, all port block F□T4 3-position, ABR connection F□T5 3-position, PAB connection F□BPC Block-off plate Manual override (-R) Manual lever override FJ With different size fitting block Valve FJ5 With single size fitting block output FJ6 With single size fitting block typeNote 2 FM With female thread block NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15) NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F 15) Notes: 1. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 2. Select from FJ, FJ5, FJ6, FM in the valve type column of the above table, and enter ○ for each station. 3. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. Quantity Delivery set 625 SOLENOID VALVES F SERIES Mounting valve models ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Order Date Split Manifold Non-Plug-in Type Specifications Confirmation Form 1/2 Company name Name of the person in charge ●Fill in selections inside the thick-lined boxes. Order No. F M N Month/ Day/ Equipment name - Station 1 Manifold model Piping block specification JR : With different size fitting on right side JL : With different size fitting on left side JD : With different size fittings on both sides MR : With female thread on right side ML : With female thread on left side MD : With female threads on both sides J5R : With single size fitting φ8 on right side (not available for F18) J6R : With single size fitting φ10 on right side (not available for F18) J5L : With single size fitting φ8 on left side (not available for F18) J6L : With single size fitting φ10 on left side (not available for F18) J5D : With single size fittings φ8 on both sides (not available for F18) J6D : With single size fittings φ10 on both sides (not available for F18) Pilot specification Blank : Internal pilot manifold G : External pilot manifold Manifold output specification J : With different size fitting block M : With female thread block L : With single size fitting block Blank : With plate (direct piping type) Valve units 2∼20 Valve size 10 : 10mm width 15 : 15mm width 18 : 18mm width 626 Year/ 2 …… n A B A B A B Solenoid Left side Piping block Right side Illustration shows the F 10 series. Split Manifold Non-Plug-in Type Specifications Confirmation Form 2/2 ●Fill in selections inside the thick-lined boxes. When manifold output specifications are J or M or L. stn. F Valve size Manual override Blank : Manual override R : Manual lever overrideNote 3 (made to order) Operation method Blank : Internal pilot type Note 1 G : External pilot typeNote 2 T Valve specification - Note 3 - A1 Note 4 - Note 5 - Note 6 Manifold fitting specification Note 5 J5 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ4, F15:φ6, F18:φ8 J6 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ6, F15:φ8, F18:φ10 Wiring specification PN : S type plug connector, without connector PS : S type plug connector, lead wire 300mm PS3 : S type plug connector, lead wire 3000mm CPS : Plus common pre-wiring connection S type plug connector, lead wire 300mm CPS3 : Plus common pre-wiring connection S type plug connector, lead wire 3000mm - Note 7 Voltage DC24V DC12V AC100V Split Blank SP SR SA : Without split : For P portNote 7 : For R portNote 7 : For both P and R ports Note 7 Individual air supply and exhaust spacer Note 6 Blank : Without spacer NPM : Individual air supply spacer (with M5 female thread for F10) NP6 : Individual air supply spacer (with φ6 fitting for F15) NP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 : Individual air supply spacer (with φ10 fitting for F18) NRM : Individual exhaust spacer (with M5 female thread for F10) NR6 : Individual exhaust spacer (with φ6 fitting for F15) NR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 : Individual exhaust spacer (with φ10 fitting for F18) Valve output type A1 : With plate (When manifold output specifications are J or M or L, the valve type is A1.) FJ : With different size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port different size fittings F10:φ4 and φ6, F15:φ6 and φ8, F18:φ8 and φ10)Note 4 FJ5 : With single size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port single size fitting F10:φ4, F15:φ6, F18:φ8)Note 4 FJ6 : With single size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port single size fitting F10:φ6, F15:φ8, F18:φ10)Note 4 FM : With female thread block (Can be selected when manifold output specification is “Blank”, valve side output port female thread F10:M5×0.8, F15:Rc1/8, F18:Rc1/4)Note 4 ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity 2-position, single solenoid only F□T0 F□T1 2-position, single solenoid specification F□T2 2-position, double solenoid specification F□T3 3-position, all port block F□T4 3-position, ABR connection F□T5 3-position, PAB connection F□BPC Block-off plate Manual override (-R) Manual lever override FJ With different size fitting block Valve FJ5 With single size fitting block output FJ6 With single size fitting block typeNote 4 FM With female thread block J5 Manifold output port single size fitting Manifold fitting specificationNote 5 J6 Manifold output port single size fitting Split (-SP) For P portNote 8 Split (-SR) For R portNote 8 Split (-SA) For both P and R portsNote 8 NPM Individual air supply spacer (with M5 female thread for F10) NP6 Individual air supply spacer (with φ6 fitting for F15) NP8 Individual air supply spacer (with φ8 fitting for F15 and F18) NP0 Individual air supply spacer (with φ10 fitting for F18) NRM Individual exhaust spacer (with M5 female thread for F10) NR6 Individual exhaust spacer (with φ6 fitting for F15) NR8 Individual exhaust spacer (with φ8 fitting for F15 and F18) NR0 Individual exhaust spacer (with φ10 fitting for F18) Notes : 1. Cannot be mounted on the external pilot manifold. 2. Cannot be mounted on the internal pilot manifold. 3. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 4. When manifold output specifications are “Blank,” select from FJ, FJ5, FJ6 or FM in the valve type column of the above table, and enter ○ for each station. 5. When the manifold output specifications are L(with single size fitting block), select from J5 or J6 in the manifold fitting specifications column of the above table, and enter ○ for each station. 6. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. 7. To designate a split, enter ○ in the split column of the designated stations in the above table. 8. Splits can be mounted as long as piping blocks are attached to both sides. In addition, the number of splits that can be mounted on one manifold set is limited to one location (one station) for -SA, for -SP,-SR limited to one location (one station) each, total 2 locations. Splits are installed at time of delivery in the space between the designated station and the station to its left Quantity Delivery set (the side with the smaller station number). 627 SOLENOID VALVES F SERIES Mounting valve models - Order Date Split Manifold Plug-in Type Specifications Confirmation Form 1/2 Company name Name of the person in charge ●Fill in selections inside the thick-lined boxes. Order No. Month/ Day/ Year/ Equipment name Station 1 2 …… n A B A B A B F M P - - - - Solenoid Piping block Piping block Voltage Left side DC24V DC12V AC100VNote 9 Right side Wiring position(wiring block) Blank : Left-side mounting R : Right-side mounting Illustration shows the F 10 series, flat cable Wiring connection specification Blank : Packed wiring W : Double wiring connector type. Manifold model Piping block specification Wiring specification JR : With different size fittings on right side F100 : Flat cable connector 10-pin JL : With different size fittings on left side F101 : Flat cable connector 10-pin JD : With different size fittings on both sides F200 : Flat cable connector 20-pin MR : With female thread on right side F201 : Flat cable connector 20-pin ML : With female thread on left side F260 : Flat cable connector 26-pin MD : With female threads on both sides D250 : D sub connector 25-pin J5R : With single size fitting φ8 on right side (not available for F18) D251 : D sub connector 25-pin J6R : With single size fitting φ10 on right side (not available for F18) T200 : Terminal block 19-terminal J5L : With single size fitting φ8 on left side (not available for F18) J6L : With single size fitting φ10 on left side (not available for F18) J5D : With single size fittings φ8 on both sides (not available for F18) J6D : With single size fittings φ10 on both sides (not available for F18) Manifold output specification J : With different size fitting block M : With female thread block L : With single size fitting block Blank : With plate (direct piping type) Pilot specification Blank : Internal pilot manifold G : External pilot manifold Valve units 2∼□Note Note : For the maximum number of units, check the table for maximum number of valve units, by wiring specification, on p.548. Valve size 10 : 10mm width 15 : 15mm width 18 : 18mm width 628 Split Manifold Plug-in Type Specifications Confirmation Form 2/2 ●Fill in selections inside the thick-boxes. When manifold output specifications are J or M or L. stn. F Valve size Manual override Blank : Manual override R : Manual lever : override Note 3 (made to order) - Valve specification Note 3 - - Note 4 Note 5 - Note 6 - Note 7 Split Blank SP SR SA Manifold fitting specification Note 5 J5 : Can be selected with manifold output specification L : (with single size fitting block). Manifold side output port single size fitting F10:φ4, F15:φ6, F18:φ8 J6 : Can be selected with manifold output specification L : (with single size fitting block). Manifold side output port single size fitting F10:φ6, F15:φ8, F18:φ10 Voltage DC24V DC12V AC100VNote 9 : Without split : For P portNote 7 : For R portNote 7 : For both P and R ports Note 7 Individual air supply and exhaust spacer Note 6 Blank : Without spacer PPM : Individual air supply spacer (with M5 female thread for F10) PP6 : Individual air supply spacer (with φ6 fitting for F15) PP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) PP0 : Individual air supply spacer (with φ10 fitting for F18) PRM : Individual exhaust spacer (with M5 female thread for F10) PR6 : Individual exhaust spacer (with φ6 fitting for F15) PR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) PR0 : Individual exhaust spacer (with φ10 fitting for F18) Valve output type A1 : With plate (When manifold output specifications are J or M or L, the valve type is A1.) FJ : With different size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port different size fittings F10:φ4 and φ6, F15:φ6 and φ8, F18:φ8 and φ10)Note 4 FJ5 : With single size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port single size fitting F10:φ4, F15:φ6, F18:φ8)Note 4 FJ6 : With single size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port single size fitting F10:φ6, F15:φ8, F18:φ10)Note 4 FM : With female thread block (Can be selected when manifold output specification is “Blank”, valve output port female thread F10:M5×0.8, F15:Rc1/8, F18:Rc1/4)Note 4 ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station 2-position, single solenoid only F□T0 F□T1 2-position, single solenoid specification F□T2 2-position, double solenoid specification F□T3 3-position, all port block F□T4 3-position, ABR connection F□T5 3-position, PAB connection F□BPP Block-off plate Manual override (-R) Manual lever override FJ With different size fitting block Valve FJ5 With single size fitting block output FJ6 With single size fitting block typeNote 4 FM With female thread block J5 Manifold output port single size fitting Manifold fitting specificationNote 5 J6 Manifold output port single size fitting Split (-SP) For P portNote 8 Split (-SR) For R portNote 8 Split (-SA) For both P and R portsNote 8 PPM Individual air supply spacer (with M5 female thread for F10) PP6 Individual air supply spacer (with φ6 fitting for F15) PP8 Individual air supply spacer (with φ8 fitting for F15 and F18) PP0 Individual air supply spacer (with φ10 fitting for F18) PRM Individual exhaust spacer (with M5 female thread for F10) PR6 Individual exhaust spacer (with φ6 fitting for F15) PR8 Individual exhaust spacer (with φ8 fitting for F15 and F18) PR0 Individual exhaust spacer (with φ10 fitting for F18) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Quantity SOLENOID VALVES F SERIES Mounting valve models Operation method Blank : Internal pilot type Note 1 G : External pilot typeNote 2 T A1 Notes : 1. Cannot be mounted on the external pilot manifold. 2. Cannot be mounted on the internal pilot manifold. 3. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 4. When manifold output specifications are “Blank,” select from FJ, FJ5, FJ6 or FM in the valve type column of the above table, and enter ○ for each station. 5. When the manifold output specifications are L(with single size fitting block), select from J5 or J6 in the manifold fitting specifications column of the above table, and enter ○ for each station. 6. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. 7. To designate a split, enter ○ in the split column of the designated stations in the above table. 8. Splits can be mounted as long as piping blocks are attached to both sides. In addition, the number of splits that can be mounted on one manifold set is limited to one location (one station) for -SA, for -SP, -SR limited to one location (one station) each, total 2 Quantity set locations. Splits are installed at time of delivery in the space between the designated station and the station to its left (the Delivery side with the smaller station number). 9. AC100V can only be used when wiring specifications are -D250, -D251 (D sub connector), or -T200 (terminal block). 629 Order Date Serial Transmission Compatible Manifold Month/ Day/ Year/ Company name Name of the person in charge Specifications Confirmation Form 1/2 Order No. ●Fill in selections inside the thick-lined boxes. Equipment name Station 1 Serial transmission block(for left-side mounting) Solenoid 2 …… n A B A B A B Piping block D - - - Left side D - Valve size 10 : 10mm width 15 : 15mm width 18 : 18mm width Illustration shows the F 10 series. Wiring connection specification Blank : Packed wiring W : Double wiring Manifold model Valve units 2∼□Note Note: For the maximum number of units, confirm the table for maximum number of valve units, by wiring specification, on p. 552, 556. Pilot specification Blank : Internal pilot manifold G : External pilot manifold Wiring position (transmission block) Blank : Left-side mounting R : Right-side mounting Note Note : For Omron CompoBus/D can only be mounted on left side. Piping block specification JR : With different size fitting on right side JL : With different size fitting on left side JD : With different size fittings on both sides MR : With female thread on right side ML : With female thread on left side MD : With female threads on both sides J5R : With single size fitting φ8 on right side (not available for F18) J6R : With single size fitting φ10 on right side (not available for F18) J5L : With single size fitting φ8 on left side (not available for F18) J6L : With single size fitting φ10 on left side (not available for F18) J5D : With single size fittings φ8 on both sides (not available for F18) J6D : With single size fittings φ10 on both sides (not available for F18) Manifold output specification J : With different size fitting block M : With female thread block L : With single size fitting block Blank : With plate (direct piping type) 630 Right side MADE IN JAPAN G 24V 0V ADDRESS 1 2 4 8 16 32 64 128 S G 24V 0V M POWER SEND F Transmission block specification 01 : For UNI-WIRE System (16-output) 02 : For UNI-WIRE System (8-output) 11 : For Mitsubishi Electric MELSECNET/MINI-S3 21 : For Omron SYSBUS Wire System 31 : For Omron B7A Link Terminal (standard) 32 : For Omron B7A Link Terminal (high-speed) 41 : For Koyo Electric Industries SA Bus (16-output) 42 : For Koyo Electric Industries SA Bus (8-output) 51 : For Sunx S-LINK (16-output) 52 : For Sunx S-LINK (8-output) 61 : For Mitsubishi Electric MELSEC I/O LINK 71 : For Fuji Electric T Link Mini 81 : For Keyence KZ-R 91 : For Omron CompoBus/D A1 : For Omron CompoBus/S (16-output) A2 : For Omron CompoBus/S (8-output) B1 : For Mitsubishi Electric CC-Link Serial Transmission Compatible Manifold Specifications Confirmation Form 2/2 When manifold output specifications are J or M or L. stn. F Valve size T - Valve specification Manual override Blank : Manual override R : Manual lever : overrideNote 3 (made to order) Note 3 A1 - Note 4 - Note 5 - Note 6 - Note 7 DC24V Individual air supply and exhaust spacer Note 6 Blank : Without spacer PPM : Individual air supply spacer (with M5 female thread for F10) PP6 : Individual air supply spacer (with φ6 fitting for F15) PP8 : Individual air supply spacer (with φ8 fitting for F15 and F18) PP0 : Individual air supply spacer (with φ10 fitting for F18) PRM : Individual exhaust spacer (with M5 female thread for F10) PR6 : Individual exhaust spacer (with φ6 fitting for F15) PR8 : Individual exhaust spacer (with φ8 fitting for F15 and F18) PR0 : Individual exhaust spacer (with φ10 fitting for F18) Operation method Blank : Internal pilot type Note 1 G : External pilot typeNote 2 Split Blank SP SR SA : Without split : For P port Note 7 : For R port Note 7 Note 7 : For both P and R ports Valve output type A1 : With plate (When manifold output specifications are J or M or L, the valve type is A1.) FJ : With different size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port different size fittings F10:φ4 and φ6, F15:φ6 and φ8, F18:φ8 and φ10)Note 4 FJ5 : With single size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port single size fitting F10:φ4, F15:φ6, F18:φ8)Note 4 FJ6 : With single size fitting block (Can be selected when manifold output specification is “Blank”, valve side output port single size fitting F10:φ6, F15:φ8, F18:φ10)Note 4 FM : With female thread block (Can be selected when manifold output specification is “Blank”, valve output port female thread F10:M5×0.8, F15:Rc1/8, F18:Rc1/4)Note 4 ※For the valve and block-off plate mounted at each station, enter ○ for each designated station below. Mounting valve, block-off plate Station 2-position, single solenoid only F□T0 F□T1 2-position, single solenoid specification F□T2 2-position, double solenoid specification F□T3 3-position, all port block F□T4 3-position, ABR connection F□T5 3-position, PAB connection F□BPP Block-off plate Manual override (-R) Manual lever override FJ With different size fitting block Valve FJ5 With single size fitting block output FJ6 With single size fitting block typeNote 4 FM With female thread block J5 Manifold output port single size fitting Manifold fitting specificationNote 5 J6 Manifold output port single size fitting Split (-SP) For P portNote 8 Split (-SR) For R portNote 8 Split (-SA) For both P and R portsNote 8 PPM Individual air supply spacer (with M5 female thread for F10) PP6 Individual air supply spacer (with φ6 fitting for F15) PP8 Individual air supply spacer (with φ8 fitting for F15 and F18) PP0 Individual air supply spacer (with φ10 fitting for F18) PRM Individual exhaust spacer (with M5 female thread for F10) PR6 Individual exhaust spacer (with φ6 fitting for F15) PR8 Individual exhaust spacer (with φ8 fitting for F15 and F18) PR0 Individual exhaust spacer (with φ10 fitting for F18) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Quantity SOLENOID VALVES F SERIES Mounting valve model Manifold fitting specification Note 5 J5 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ4, F15:φ6, F18:φ8 J6 : Can be selected with manifold output specification L (with single size fitting block). Manifold side output port single size fitting F10:φ6, F15:φ8, F18:φ10 Notes : 1. Cannot be mounted on the external pilot manifold. 2. Cannot be mounted on the internal pilot manifold. 3. To designate a manual lever override, enter ○ in the manual override column of the designated stations in the above table. 4. When manifold output specifications are “Blank,” select from FJ, FJ5, FJ6 or FM in valve type column of the above table, and enter ○ for each station. 5. When the manifold output specifications are L(with single size fitting block), select from J5 or J6 in the manifold fitting specifications column of the above table, and enter ○ for each station. 6. When mounting the individual air supply or exhaust spacer, enter ○ in the spacer column of the designated stations in the above table. 7. To designate a split, enter ○ in the split column of the designated stations in the above table. 8. Splits can be mounted as long as piping blocks are attached to both sides. In addition, the number of splits that can be mounted on one manifold set is limited to one location (one station) for -SA, for -SP, -SR limited to one location (one station) each, total 2 locations. Splits are installed at time of delivery in the space between the designated station and the station to its left Quantity (the side with the smaller station number). set Delivery 631