NOTE! Without an offset NTP operates on UTC. Under normal conditions setting the hour
of the NTP offset suffices to work in local time. The LX60 clock does not automatically
adjust for daylight savings time.
5.4.1.2. Setting System Time Manually
Follow the instructions to set the system time manually:
1.
2.
3.
4.
In the web UI, click the Configuration tab.
In the Time field, verify that the Use NTP check box is cleared.
Enter the current time in the format HH:MM:SS in the field next to the Set Time button.
Click Set Time to update the system time.
5.4.2. Configuring Network Settings
The network field is used to configure the lamp to use either static or dynamic IP addresses. By
default, the lamp is configured to use a dynamic IP address. If unsure, it is recommended to use the
default settings.
Follow the instructions to setup a static IP address for the lamp:
1.
2.
3.
4.
5.
6.
7.
8.
In the web UI, click the Configuration tab.
In the Network field, select the Static IP radio button.
Enter IP address.
Enter Subnet.
Enter default Gateway.
Enter primary DNS in the DNS1 field.
Enter secondary DNS in the DNS2 field.
Click Update.
5.4.3. Configuring Lamp Operation Mode
The LX60 lamp can operate in any of the roles and modes described in Table 4 Lamp Roles and
Operation Modes:
Table 4 Lamp Roles and Operation Modes
Role/Mode
Schedule driven
Manual control
Master driven
Independent
Yes
Yes
No
Master
Yes
Yes
No
Slave
No
No
Yes
26 | P a g e
LX60 User Manual, Version 1