Download AHRS Interface Control Document
Transcript
AHRS Interface Control Document High (warning) byte 3 Accelerometer Unit 4 Magnetometer Unit 5 Electronics 6 Software 7 8 AHRS mode 9 Incorrect Power Supply 10 11 Angular Rate Exceeding Detect 12 13 Large Magnetic Field Detect 14 Environmental Temperature 15 AHRS mode 0 – No failure 1 – Failure detected 0 – No failure 1 – Failure detected 0 – No failure 1 – Failure detected 0 – No failure 1 – Failure detected See the Table 6.19 0 – Supply voltage is not less than minimum level 1 – Low supply voltage detected 0 – Supply voltage is not higher than maximum level 1 – High supply voltage detected 0 – X-angular rate is within the range 1 – X-angular rate is outrange 0 – Y-angular rate is within the range 1 – Y-angular rate is outrange 0 – Z-angular rate is within the range 1 – Z-angular rate is outrange 0 – Total magnetic field is within the normal range 1 – Total magnetic field limit is exceeded 0 – Temperature is within the operating range 1 – Temperature is out of the operating range See the Table 6.19 The AHRS indicates its current mode of operation in the bits 7 and 15 as the Table 6.19 shows: Inertial Labs, IncTM Address: 13800 Coppermine Road, Suite 300, Herndon, VA 20171, USA Tel: +1 (703) 880-4222, Fax: +1 (703) 935-8377 Website: www.inertiallabs.com 45