Download Manual - Sin
Transcript
DiN, Di Pumphead use is independent of drive ingress protection. No reference to ingress protection rating or drive model (620DiN or 620Di) is made throughout the pumphead sections of this manual. 27 620RE MarkII, 620RE4 MarkII and 620R MarkII pumpheads Note: MarkII pumpheads differ from MarkI pumpheads as follows: they have a new guard-switching arrangement which is not compatible with 623/624 drives. Similarly, older guards are incompatible with 620 drives. Elsewhere in this manual, the term “MarkII” is omitted. 27.1 620RE, 620RE4 and 620R key safety information Before opening the pumphead guard please ensure that the following safety directions are followed. Ensure that the pump is isolated from mains voltage. Ensure that there is no pressure in the pipeline. If a tube failure has occurred, ensure that any product in the pumphead has been allowed to drain through the controlled waste to a suitable drain. Ensure that protective clothing and eye protection are worn if hazardous products are being pumped. 27.2 620RE, 620RE4 and 620R safe-guarding Primary safety on 620 series pumps is provided by the tool-lockable pumphead guard. Secondary (backup) protection is provided in the form of an electrical guard switch which stops the pump if the pumphead guard is opened. The electrical guard switch on cased pumps should never be used as primary protection. Always disconnect the mains power supply to the pump before opening the pumphead guard. Watson-Marlow 620DiN, 620Di User Manual 99