Download OPERATION MANUAL Position Control Units - Support
Transcript
Section 11-2 Basic Program Examples These Work Area bits are used to show the progress of function execution and the execution status. Holding Area (HR Area) H1.00 This bit is used as a switch to indicate whether positioning is performed with ABSOLUTE MOVEMENT or RELATIVE MOVEMENT. Timer Area TIM0003 Used as a watchdog timer to monitor the positioning operation. This sample program starts Axis 1 positioning when the Positioning execution condition goes ON. The position command value must be set to the target position and the speed command value must be set to the target speed in the Axis Operating Output Memory Area before executing this sample program. At this point, the ON/OFF status of HR1.00 determines whether the positioning is executed with RELATIVE MOVEMENT (HR1.00 OFF) or ABSOLUTE MOVEMENT (HR1.00 ON). If axis 1 positioning is not completed within 10 seconds after completion of sending the positioning command, i.e., after pulse distribution is completed, a Positioning Timeout will occur and bit W201.03 will be turned ON for one cycle. The target position can be changed during an Absolute Movement or Relative Movement positioning operation by setting a new position command value and turning ON the ABSOLUTE or RELATIVE MOVEMENT Bit. Torque limits can also be enabled/disabled during positioning by turning ON/OFF the forward and reverse rotation current limit bits in the Axis Operating Output Memory Area and turning ON the ABSOLUTE or RELATIVE MOVEMENT Bit. This sample program allows the target position to be changed during an operation by turning the execution condition OFF and then ON again. A Multistart Error will occur if a Movement command is sent while the PCU's Receiving Command Flag is already ON, so the Receiving Command Flag is ANDed with the Positioning execution condition (in the W201.00 output circuit). An OR circuit containing the ABSOLUTE MOVEMENT Bit and RELATIVE MOVEMENT Bit has been added so that the W201.00 is not output again when the Receiving Command Flag goes from ON to OFF. The target speed can be changed sequentially during operation by overwriting the speed command value in the Axis Operating Output Memory Area. 416
Related documents
G Series Servomotors/Drives w/Mechatrolink
Axis 2400+ Instruction manual
Raymarine Satellite TV Systems User`s guide
CS1W-NC 71 - OMRON Industrial Automation
Sigma-II Series SGDH MECHATROLINK-II - Support
FX-PCS/WIN-E SOFTWARE MANUAL
D-V4 CX-Motion-NCF Ver. 1.9 Operation Manual
SmartPilot X-5 - Busse Yachtshop
Sigma-II Series SGDH MECHATROLINK
User Manual for the Third-Generation, Advanced Piston Corer
SGDS Sigma III Servo Amplifier User Manual for Mechatrolink
OPERATION MANUAL