Download Linux: IBM Installation Toolkit User Manual

Transcript
BRLMU0001W: Firmware update disabled
The Firmware update is disabled when the context does not permit this feature to be used. This could
happen while trying to update the firmware of an unsupported architecture.
BRLMU0002W: Could not determine system's architecture
The architecture of the machine running the IBM Installation Toolkit could not be automatically
determined. This probably means that you are running the system using an HMC machine. If this is your
case, you should use the HMC's interface to perform the action.
BRLMU0003E: Error fetching firmware information
The wizard was not able to determine the system's firmware data. This may be caused by a missing or
incorrectly installed lsvpd package. Try verifying if the package is correctly running on the system.
BRLMU0004E: Permanent firmware running
Firmware updates cannot be performed while the system is running with the firmware from the
permanent side. Reboot the system with the firmware from the temporary side and try again.
BRLMU0005E: Could not mount CD/DVD
The wizard was not able to create the mount point directory in order to mount the IBM Installation
Toolkit media. Verify if the filesystem permissions are correctly set to allow the creation of the directory
mount point specified in the wizard's error message and try again.
BRLMU0006E: IBM Installation Toolkit media not found
The wizard could not find the IBM Installation Toolkit media in any of the optical devices. Check the
media inserted and try again.
BRLMU0007E: No firmware available
The IBM Installation Toolkit media does not contain any suitable firmware image for the machine.
Consider downloading a firmware image file and select it at the filesystem menu in the wizard.
BRLMU0008I: No CD/DVD drive found
No CD/DVD drive was found in your system. Because of that, no option is available to load firmware
images from the IBMIT DVD. If you have a CD/DVD drive, it may not be working.
BRLMU0009E: Could not validate file type; IBM Installation Toolkit media not found
A problem occurred while trying to access the media in the drive. Verify if the media is inserted in the
drive and it is correctly working.
BRLMU0010E: The file %s is not a valid firmware image
The firmware file selected is not a valid RPM package or raw data file. Verify the file provided and try
again.
BRLMU0011E: No firmware image file chosen
You have to select a firmware image file in order to proceed.
174