Download SH7410 E8000 Emulator HS7410EDD82H User`s Manual

Transcript
TRACE_DISPLAY_MODE
7.2.44
TRACE_DISPLAY_MODE
Specifies and displays trace information
[TDM]
display mode
Command Format
• Setting
TRACE_DISPLAY_MODE∆PTR=[–]<start pointer>
[:[–]<end pointer>]∆<display item>=(D/E)
[[∆<display item>=(D/E)]...][;C] (RET)
• Display
TRACE_DISPLAY_MODE (RET)
<start pointer>: Default start pointer for trace information display and search
(emulator shipment: –D'4095)
<end pointer>: Default end pointer for trace information display and search
(emulator shipment: D'4095)
<display item>: Information to be displayed at trace information display
A (address bus), D (data bus), MA (memory area type),
RW (read/write), ST (status), IRQ (IRQ signals),
NMI (NMI signal), RES (RESET signal),
BREQ (BREQ signal), VCC (VCC voltage state),
PRB (external probe), TIME (time stamp), and CLK
(clock cycle)
C: Stores the settings as configuration information in the emulator
flash memory
Description
• Setting
 Specifies the default values of start and end pointers for trace information display and
search which are used when the pointer values are not specified in the TRACE or
TRACE_SEARCH command. Trace information in the emulator is available for
approximately 128,000 bus cycles. Use this command to specify the range of the default
values when all trace information is not required. The specified pointers will function as
bus-cycle pointers in the TRACE_SEARCH command, and according to the option as
instruction or bus-cycle pointers in the TRACE command. The pointer value ranges from
–131070 to 131070. When exceeding this range, start and end pointers are automatically
specified as –131070 and 131070, respectively.
: TRACE_DISPLAY_MODE PTR = –D'2048:D'2048 (RET)
Rev. 1.0, 09/00, page 349 of 436