Download R&S UPP User Manual

Transcript
R&S®UPP
Remote Control - Command Description
Combi Display
SENSe<n1>:REFerence<n2> <reference>
Suffix:
<n1>
.
specifies the type of measurement.
1 = function measurement (level / signal to noise / distortion, ...)
2 = input monitor measurement
6 = level monitor measurement
Parameters:
<reference>
float
Manual operation:
See "Reference" on page 564
SENSe<n1>:REFerence<n2>:MODE<n3> <mode>
Suffix:
<n1>
Parameters:
<mode>
Manual operation:
.
specifies the type of measurement.
1 = function measurement (level / signal to noise / distortion, ...)
2 = input monitor measurement
6 = level monitor measurement
CH1Meas | CH2Meas | VALue | STORe | SOURce | GENTrack |
MREFchannel | CH1Store | CH2Store | CH3Store | CH4Store |
CH5Store | CH6Store | CH7Store | CH8Store
See "Reference" on page 564
SENSe<n1>:RIGHt<n2> <right>
Suffix:
<n1>
.
1|2|6
<n2>
1|2
Parameters:
<right>
float
Manual operation:
See "Right" on page 566
SENSe<n1>:UNAuto<n2> <unauto>
Suffix:
<n1>
.
specifies the type of measurement.
1 = function measurement (level / signal to noise / distortion, ...)
2 = input monitor measurement
6 = level monitor measurement
Parameters:
<unauto>
ON | OFF
Manual operation:
See "Unit Auto" on page 562
User Manual 1411.1055.32 ─ 04
775