Download User Manual
Transcript
8 channel DMX chart 4.4 DMX512 CONNECTION Channel Value Function CH1 000-255 Full dimmer, 0-100% 000-008 No function CH2 CH3 009-255 Strobe, slow to fast 000-255 The first head, Y position 000-008 No function 129-136 R+G+B 009-016 R 137-144 R+G+W 017-024 G 145-152 R+G+A 025-032 B 153-160 R+B+W 033-040 W 161-168 R+B+A CH4 041-048 A 169-176 R+W+A (The first 049-056 R+G 177-184 G+B+W head, LED 057-064 R+B 185-192 G+B+A colour 065-072 R+W 193-200 G+W+A selection) 073-080 R+A 201-208 B+W+A 081-088 G+B 209-216 R+G+B+W 089-096 G+W 217-224 R+G+W+A 097-104 G+A 225-232 R+G+B+A 105-112 B+W 233-240 R+B+W+A 113-120 B+A 241-248 G+B+W+A 121-128 W+A 249-255 R+B+A+W+A CH5 CH6 CH7 CH8 000-255 The second head, Y position 000-008 No function 009-255 The second head, LED colour selection 000-255 The third head, Y position 000-008 No function 009-255 The third head, LED colour selection 1. In the last unit, the DMX has to be terminated with a termination plug. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit. 2. Connect the units together in a `daisy chain` with an XLR plug from the output of the unit to the input of the next unit. The cable can not be branched or split to a `Y` cable. 3. The DMX output and input connectors are a pass-through type to maintain the DMX circuit when one of the units’ power is disconnected. 4. Each lighting unit needs to have an address setup to receive the data sent by the controller. The address number is between 0-512 5. The end of the DMX 512 system should be terminated to reduce signal errors. 6. 3 pin XLR cable wiring configuration 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)