Download User Manual - K J Electric
Transcript
Parameters Motor PNU ID Access RUN Value/Range Description Factory Setting (P1.3) P7.1 113 X — Motor, rated operational current Ie 0.2 x Ie–2 x Ie (A) Ie = Frequency inverter’s rated operational current (See figure on Page 86.) P7.2 P7.3 107 112 X X — Current limit 0.2 x Ie–2 x Ie (A) Factory setting: 1.5 x Ie — Motor, rated speed 300–20000 RPM (min–1) (See figure on Page 86.) 1.5 x Ie P7.4 120 X — Motor, power factor (cos ) 0.30–1.00 (See figure on Page 86.) P7.5 110 X — Motor, rated operating voltage 180–676V (See figure on Page 86.) Pay attention to the supply voltage and the type of circuit in the stator winding P7.6 111 X — Motor, rated frequency 30–320 Hz (See figure on Page 86.) 60.00 Note Default values vary based on actual unit ratings. M-Max Series Adjustable Frequency Drive MN04020003E—April 2011 www.eaton.com 87