Chapter 2 General Functions Set_Timetag_Res_MA Description sets the resolution of the Time tag used in the RT and Monitor Mode. There are six Time tag resolutions. [Default = 4μs.] There is also an option to take the Time tag from an external clock source (which is connected to the clock on the carrier board, which in turn may be connected to a truly external Time tag.) See section B.1.3 External Time Tag Clock Register on page B-2 Set_Timetag_Res_MA Note: Set Set_Timetag_Res_MA before starting RT or Monitor mode. (int handle, EXC_MA_TIMETAG_RES_OPTION resOption) Syntax Set_Timetag_Res_MA Input Parameters handle The handle designated by Init_Module_MA resOption Output Parameters none Return Values EXC_MA_ERROR_ BAD_HANDLE One of the following options EXC_MA_TTAGRES_64us 64μs EXC_MA_TTAGRES_32us 32μs EXC_MA_TTAGRES_16us 16μs EXC_MA_TTAGRES_8us 8μs EXC_MA_TTAGRES_4us 4μs EXC_MA_TTAGRES_2us 2μs EXC_MA_TTAGRES_EXTERNAL Take Time tag from an external source. See EXC-4000P104plus User’s Manual If an invalid handle was specified; should be value returned by Init_Module_MA EXC_MA_ERROR_ ILLEGAL_INPUT If an invalid parameter was used as an input EXC_MA_STATUS_OK No errors M4K1553MA Software Tools: Programmer’s Reference page 2 - 11