Download HP StorageWorks HSG60 and HSG80 Array Controller

Transcript
Last Failure Codes
Table 56: Last Failure Codes and Repair Action Codes (Sheet 42 of 55)
Last
Failure
Code
Description
Repair
Action
Code
0E096980
This controller detected a failed link during repetitive signalling, or
heartbeat, to a remote target. The ”other controller” has a good link to
the remote target. In order to resume operations to that remote target,
“this controller” is restarted to fail over the initiator unit to the “other
controller.”
69
0E0A6980
A remote copy write has failed all recovery attempts on “this controller.”
As part of further error recovery, “this controller” is restarted, to force the
initiator unit over to the “other controller” so the remote copy can be
retried.
69
0E0B6980
“This controller” detected a failed link upon restarting dual-redundant
controllers. The “other controller” has a good link to the remote target. In
order to resume operations to that remote target, “this controller” is
restarted to fail over the initiator unit to the “other controller.”
69
0E0C0101
Unrecognized request to perform Write History Log (WHL) operation on
other controller.
01
Last Failure Parameter [0] contains operation request.
0E0D0101
Unrecognized WHL operation ID received from other controller.
01
Last Failure Parameter [0] contains an operation ID.
0E0E0101
An illegal failover request was given to the WHL request handler.
01
Last Failure Parameter [0] contains a failover request.
0E0F0101
An illegal failover response was given to the WHL response handler.
01
Last Failure Parameter [0] contains a failover response.
0E100100
The Write History Log failover control had a bad send count.
01
0E110100
Unable to allocate memory for WHL DBs
01
0E120100
Unable to allocate memory for WHL HTBs.
01
0E130100
Unable to allocate memory for WHL HTBs.
01
0E140100
Unable to allocate memory for WHL HTBs.
0E150101
Unable to allocate memory for WHL metadata.
01
Last Failure Parameter [0] contains response failure code.
0E160100
An illegal WHL lock state was detected.
HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
01
255