Download HP StorageWorks HSG60 and HSG80 Array Controller
Transcript
Last Failure Codes Table 56: Last Failure Codes and Repair Action Codes (Sheet 42 of 55) Last Failure Code Description Repair Action Code 0E096980 This controller detected a failed link during repetitive signalling, or heartbeat, to a remote target. The ”other controller” has a good link to the remote target. In order to resume operations to that remote target, “this controller” is restarted to fail over the initiator unit to the “other controller.” 69 0E0A6980 A remote copy write has failed all recovery attempts on “this controller.” As part of further error recovery, “this controller” is restarted, to force the initiator unit over to the “other controller” so the remote copy can be retried. 69 0E0B6980 “This controller” detected a failed link upon restarting dual-redundant controllers. The “other controller” has a good link to the remote target. In order to resume operations to that remote target, “this controller” is restarted to fail over the initiator unit to the “other controller.” 69 0E0C0101 Unrecognized request to perform Write History Log (WHL) operation on other controller. 01 Last Failure Parameter [0] contains operation request. 0E0D0101 Unrecognized WHL operation ID received from other controller. 01 Last Failure Parameter [0] contains an operation ID. 0E0E0101 An illegal failover request was given to the WHL request handler. 01 Last Failure Parameter [0] contains a failover request. 0E0F0101 An illegal failover response was given to the WHL response handler. 01 Last Failure Parameter [0] contains a failover response. 0E100100 The Write History Log failover control had a bad send count. 01 0E110100 Unable to allocate memory for WHL DBs 01 0E120100 Unable to allocate memory for WHL HTBs. 01 0E130100 Unable to allocate memory for WHL HTBs. 01 0E140100 Unable to allocate memory for WHL HTBs. 0E150101 Unable to allocate memory for WHL metadata. 01 Last Failure Parameter [0] contains response failure code. 0E160100 An illegal WHL lock state was detected. HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide 01 255