Download User Manual
Transcript
15.5 MEWTOCOL-COM Communication Commands Table of MEWTOCOL-COM commands Command name Read contact area Code RC (RCS) (RCP) (RCC) Description Reads the on and off status of contact. - Specifies only one point. - Specifies multiple contacts. - Specifies a range in word units. Turns contacts on and off. Write contact area WC (WCS) (WCP) (WCC) Read data area Write data area Read timer/counter set value area Write timer/counter set value area Read timer/counter ellapsed value area Write timer/counter elapsed value area Register or Reset contacts monitored Register or Reset data monitored RD WD RS WS RK WK MC MD Monitoring start MG Preset contact area (fill command) SC Preset data area (fill command) SD Read system register Write system register RR WR Read the status of PLC RT Remote control RM Abort AB Reads the contents of a data area. Writes data to a data area. Reads the value set for a timer/counter. Writes a timer/counter setting value. Reads the timer/counter elapsed value. Writes the timer/counter elapsed value. Registers the contact to be monitored. Registers the data to be monitored. Monitors a registered contact or data using the code “MC or MD”. Embeds the areaof a specified range in a 16point on and off pattern. Writes the same contents to the data area of a specified range. Reads the contents of a system register. Specifies the contents of a system register. Reads the specifications of the programmable controller and error codes if an error occurs. Switches the operation mode of the programmable controller. Aborts communication. - Specifies only one point. - Specifies multiple contacts. - Specifies a range in word units. 15-81