[Md.61] Analysis complete flag This area stores the start preparation complete state in the pre-analysis mode. Analysis complete flag Stored value Analysis not completed 0 Analysis completed 1 In the interpolation control, only the value of the reference axis is changed. ■Buffer memory address The following table shows the buffer memory address of this area. Buffer memory name Axis 1 Axis 2 Axis 3 Axis 4 [Md.61] Analysis complete flag 858 958 1058 1158 [Md.48] Deceleration start flag • When the speed status is changed from the constant speed or acceleration to deceleration during the position control whose operation pattern is Positioning complete, this area stores 1. • At the next operation start or manual pulse generator operation enable, it stores 0. ■Buffer memory address The following table shows the buffer memory address of this area. Buffer memory name Axis 1 Axis 2 Axis 3 Axis 4 [Md.48] Deceleration start flag 899 999 1099 1199 460 12 DATA USED FOR POSITIONING CONTROL 12.7 Monitor Data