[Md.61] Analysis complete flag
This area stores the start preparation complete state in the pre-analysis mode.
Analysis complete flag
Stored value
Analysis not completed
0
Analysis completed
1
In the interpolation control, only the value of the reference axis is changed.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.61] Analysis complete flag
858
958
1058
1158
[Md.48] Deceleration start flag
• When the speed status is changed from the constant speed or acceleration to deceleration during the position control
whose operation pattern is Positioning complete, this area stores 1.
• At the next operation start or manual pulse generator operation enable, it stores 0.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
Axis 1
Axis 2
Axis 3
Axis 4
[Md.48] Deceleration start flag
899
999
1099
1199
460
12 DATA USED FOR POSITIONING CONTROL
12.7 Monitor Data