Download PONDS Version 2.26 Users Manual.

Transcript
PONDS USER MANUAL
E-10
9.
Compute cumulative flow rate for the longest lateral in the system (i.e., the lateral
length specified on the input screen)
10.
Compute minimum pipe diameter from Manning's formula for the longest lateral in
the system using the following equation:
11.
Compute cumulative flow rate for the main line which is connected to P% of the
total length of laterals in the system
12.
Compute minimum pipe diameter from Manning's formula for the main line in the
system using the following equation:
August 7, 1995