Download Errata Sheet
Transcript
Errata Sheet Functional Deviations Workaround Avoid faulty configurations with more than gSyncNodeMax nodes configured to be transmitter of sync frames. FlexRay_AI.069 Update of Aggregated Channel Status ACS in dynamic segment in minislots following slot ID 2047 Description: In case the slot counter has reached ID 2047 and the end of dynamic segment is not reached, the slot counter wraps around to 0 and stays there until the end of the dynamic segment. In this state (slot counter = 0) the E-Ray erroneously updates register ACS every minislot. The correct behaviour is that the slot status is only updated at the end of the dynamic segment. Scope: The erratum is limited to the following case: gNumberOfStaticSlots + gNumberOfMinislots > cSlotIDMax = 2047. Effects: In the described case register ACS is updated every minislot until the end of the dynamic segment. This update may also lead to an update of error interrupt flags EIR.EDA, EIR.EDB. Workaround Avoid configurations with gNumberOfStaticSlots + gNumberOfMinislots > cSlotIDMax. FlexRay_AI.070 Cycle counter MTCCV.CCV is updated erroneously in dedicated startup states Description: TC1797, QS-AC 51/115 Rel. 1.4, 25.01.2011